Catalog excerpts
IMPORTANT PRODUCT INFORMATION: CONSTELLATION® VISION SYSTEM viscoelastic prior to using power, excessively tight incisions, and combinations of the above actions may result in significant temperature increases at incision site and inside the eye, and lead to severe thermal eye tissue damage. • Adjusting aspiration rates or vacuum limits above the preset values, or lowering the IV pole below the preset values, may cause chamber shallowing or collapse which may result in patient injury. • When filling handpiece test chamber, if stream of fluid is weak or absent, good fluidics response will be jeopardized. Good clinical practice dictates the testing for adequate irrigation and aspiration flow prior to entering the eye. • Ensure that tubings are not occluded or pinched during any phase of operation. CAUTION: Federal law restricts this device to sale by, or on the order of, a physician. As part of a properly maintained surgical environment, it is recommended that a backup IOL Injector be made available in the event the AutoSert® IOL Injector Handpiece does not perform as expected. INDICATIONS FOR USE: The CONSTELLATION® Vision System is an ophthalmic microsurgical system that is indicated for both anterior segment (i.e., phacoemulsification and removal of cataracts) and posterior segment (i.e., vitreoretinal) ophthalmic surgery. The ULTRAVIT® Vitrectomy Probe is indicated for vitreous cutting and aspiration, membrane cutting and aspiration, dissection of tissue and lens removal. The valved entry system is indicated for scleral incision, canulae for posterior instrument access and venting of valved cannulae. The infusion cannula is indicated for posterior segment infusion of liquid or gas. ADVERSE EVENTS/COMPLICATIONS: Use of handpieces during intraocular procedures in the absence of irrigation flow and/or in the presence of reduced or lost aspiration flow can cause excessive heating and potential thermal injury to adjacent eye tissues. The PUREPOINT® Laser is indicated for use in photocoagulation of both anterior and posterior segments of the eye including: • Retinal photocoagulation, panretinal photocoagulation and intravitreal endophotocoagulation of vascular and structural abnormalities of the retina and choroid including: Proliferative and nonproliferative retinopathy (including diabetic); choroidal neovascularization secondary to age-related macular degeneration; retinal tears and detachments; macular edema, retinopathy of prematurity; choroidal neovascularization; leaking microaneurysms. • Iridotomy/Iridectomy for treatment of chronic/primary open angle glaucoma, acute angle closure glaucoma and refractory glaucoma. • Trabeculoplasty for treatment of chronic/primary open angle glaucoma and refractory glaucoma. • And other laser treatments including: internal sclerostomy; lattice degeneration; central and branch retinal vein occlusion; suturelysis; vascular and pigment skin lesions. The FlexTip* laser probe is intended to be used with ALCON® 532nm laser systems. The CONSTELLATION® Vision System: ATTENTION: Please refer to the CONSTELLATION® Vision System Operators Manual for a complete listing of indications, warnings, and precautions. WARNINGS AND PRECAUTIONS: • Potential risk from reuse or reprocessing GRIESHABER® DSP instruments include: foreign particle introduction to the eye; reduced cutting or grasping performance; path leaks or obstruction resulting in reduced fluidics performance. • Verify correct tip attachment, function and tip actuation before placing it into the eye for surgery. • For light fiber instruments: Minimize light intensity and duration of exposure to the retina to reduce risk of retinal photic injury. The light fiber instruments are designed for use with an ALCON® illumination source. • Good clinical practice dictates the testing for adequate irrigation and aspiration flow prior to entering the eye. If stream of fluid is weak or absent, good fluidics response will be jeopardized. • Use appropriate pressure supply to ensure a stable IOP. • If unwanted tissue gets engaged to the aspiration port, it should be released by interrupting aspiration before moving the instrument. The CONSTELLATION Vision System is also indicated for emulsification, separation, and removal of cataracts, the removal of residual cortical material and lens epithelial cells, vitreous aspiration and cutting associated with anterior vitrectomy, bipolar coagulation, and intra-ocular lens injection. The INTREPID® AutoSert® IOL Injector Handpiece is intended to deliver qualified AcrySof® intraocular lenses into the eye following cataract removal. The following system modalities additionally support the described indications: • Ultrasound with UltraChopper® Tip achieves the functionality of cataract separation. • The INTREPID® AutoSert® IOL Injector Handpiece achieves the functionality of injection of intraocular lenses. The INTREPID® AutoSert® IOL Injector Handpiece is indicated for use with AcrySof® lenses SN60WF, SN6AD1, SN6AT3 through SN6AT9, as well as approved AcrySof® lenses that are specifically indicated for use with this inserter, as indicated in the approved labeling of those lenses. WARNINGS AND PRECAUTIONS: • The disposables used in conjunction with ALCON® instrument products constitute a complete surgical system. Use of disposables and handpieces other than those manufactured by Alcon may affect system performance and create potential hazards. • Attach only Alcon supplied consumables to console and cassette luer fittings. Do not connect consumables to the patient’s intravenous connections. • Mismatch of consumable components and use of settings not specifically adjusted for a particular combination of consumable components may create a patient hazard. • Vitreous traction has been known to create retinal tears and retinal detachments. • The closed loop system of the CONSTELLATION® Vision System that adjusts IOP cannot replace the standard of care in judging IOP intraoperatively. If the surgeon believes that the IOP is not responding to the system settings and is dangerously high or low, this may represent a system failure. Note: To ensure proper IOP Compensation calibration, place infusion tubing and infusion cannula on a sterile draped tray at mid-cassette level during the priming cycle. • Leaking sclerotomy may lead to post operative hypotony. • Back scattered radiation is of low intensity and is not harmful when viewed through a protective filter. All personnel in the treatment room must wear protective eyewear, OD4 or above at 532nm, when the system is in Standby/Ready mode as well as during treatment. The doctor protection filter is an OD greater than 4 at 532nm. • The infusion cannula is contraindicated for use of oil infusion. • Attach only Alcon supplied products to console and cassette luer fittings. Improper usage or assembly could result in a potentially hazardous condition for the patient. Mismatch of surgical components and use of settings not specifically adjusted for a particular combination of surgical components may affect system performance and create a patient hazard. Do not connect surgical components to the patient’s intravenous connections. • Each surgical equipment/component combination may require specific surgical setting adjustments. Ensure that appropriate system settings are used with each product combination. Prior to initial use, contact your Alcon sales representative for in-service information. • Care should be taken when inserting sharp instruments through the valve of the Valved Trocar Cannula. Cutting instrument such as vitreous cutters should not be actuated during insertion or removal to avoid cutting the valve membrane. Use the Valved Cannula Vent to vent fluids or gases as needed during injection of viscous oils or heavy liquids. • Visually confirm that adequate air and liquid infusion flow occurs prior to attachment of infusion cannula to the eye. • Ensure proper placement of trocar cannulas to prevent sub-retinal infusion. • Minimize light intensity and duration of exposure to the retina to reduce the risk of retinal photic injury. • Use of low vacuum limits, low flow rates, low bottle heights, high power settings, extended power usage, power usage during occlusion conditions (beeping tones), failure to sufficiently aspirate *Trademarks are property of their respective owners. GRIEBHABER® DSP INSTRUMENTS CAUTION: Federal (USA) law restricts this device to sale by, or on the order of, a physician. INDICATIONS FOR USE: GRIESHABER® DSP instruments are a line of single-use vitreoretinal microinstruments which are used in ophthalmic surgery, for cases either in the anterior or the posterior segment. The GRIESHABER® Advanced Backflush Handles DSP are a family of instruments for fluid and gas handling in vitreoretinal surgery. ATTENTION: Please refer to the product labeling for a complete listing of indications, warnings, and precautions. REFERENCES: 1. A bulon, et al. Porcine Vitreous Flow Behavior During High Speed Vitrectomy up to 7500 Cuts Per Minute. ARVO Poster, 2012. 2. B uboltz, DC. New Method for Evaluating Flow Rates and Intraocular Pressures During Simulated Vitreoretinal Surgeries. Poster, ARVO Congress, 2010. Fort Lauderdale, FL. 3. R ieman CD, Buboltz DC, and Abulon DJ. Prevention of Intraoperative Hypotony During Vitreoretinal Surgery: An Instrumental Comparison. Poster, Retina Society Conference, 2010. San Francisco, CA. 4. N agpal M, Wartikar S, Nagpal K. Comparison of clinical outcomes and wound dynamics of sclerotomy ports of 20, 25, and 23 gauge vitrectomy. Retina. 2009;29(2):225-231. 5. D avison J. Cumulative tip travel and implied followability of longitudinal and torsional phacoemulsification. J Cataract Refract Surg. 2008;34:986-990. 6. Fernández de Castro LE, et al. Bead-flow pattern: quantization of fluid movement during torsional and longitudinal phacoemulsification. Journal of Cataract & Refractive Surgery. 2010;36(6):1018-1023. 7. Alcon data on file 954-0000-004. 8. C hu T, et al. Comparison of aqueous flow rates with two commercially available vitrectomy systems. ARVO Poster Presentation, 2010. 9. C harles S. The physics of vitrectomy and advanced fluidics. Retina Today Supplement. September/October 2008. 10. R iemann C, et al. Vitreous cutter velocities: dual pneumatic drive vs. single pneumatic drive with spring return probes. ASCRS Poster Presentation, 2011. 11. Packo K. True IOP control and infusion cannula fluidics with the CONSTELLATION® Vision System. Retinal Physician. October, 2010. 12.C harles M, Charles DE, Abulon DJ. Comparing intraocular pressure (IOP) of valved and non-v alved cannulas during simulated vitrectomy in a rubber eye model. ASRS Poster Presentation,2013. † 13. L iu Y, et al. Torsional mode versus conventional ultrasound mode phacoemulsification. J Cataract Refract Surg. 2007;33:287-292. 14. C ionni R. Comparison of nuclear material chatter: longitudinal versus torsional phacoemulsification. Paper presented at: The ASCRS Symposium on Cataract, IOL and Refractive Surgery; April 30, 2007; San Diego, CA. 15. H an Y, et al. Heat production: longitudinal versus torsional phacoemulsification. J Cataract Refract Surg. 2009;35:1799-1805. 16. J un B, Berdahl JP, and Kim T. Thermal study of longitudinal and torsional ultrasound phacoemulsification: Tracking the temperature of the corneal surface, incision, and handpiece. Journal of Cataract & Refractive Surgery. 2010;36(5):832-837. 17. Z acharias J. Thermal characterization of phaco probes operated in torsional and longitudinal modalities using alternative methodologies. In ASCRS. 2011. San Diego, CA. 18. Vasavada AR, et al., Comparison of torsional and microburst longitudinal phacoemulsification: a prospective, randomized, masked clinical trial. Ophthalmic Surg Lasers Imaging. 2010;41(1):109-114.
Open the catalog to page 1All Alcon catalogs and technical brochures
-
PUREPOINT
2 Pages
-
Vektor
2 Pages
-
NEGENUITY
2 Pages
-
MODEL MA50BM
11 Pages
-
Maintaining Good Eye Health
3 Pages
-
The LenSx® Laser System
12 Pages
-
CZ70BD
7 Pages
-
MODEL SN6AT3, SN6AT4, SN6AT5
23 Pages
-
MODEL SN60AT
9 Pages
-
MODEL SN6AD1
26 Pages
-
MODEL MA30AC
11 Pages
-
MODEL MN60AC
13 Pages
-
MODEL SN60WF
15 Pages
-
MODEL SN6CWS
15 Pages
-
NAPHCON A
1 Pages
-
PUREPOINT LASER
6 Pages
-
CONSTELLATION® Vision System
10 Pages