SIDECAR®
2Pages

{{requestButtons}}

Catalog excerpts

SIDECAR® - 1

FIRST AUTOMATED STREAKING SYSTEM INTEGRATED WITH THE RAPID BACTERIA CULTURE THE FIRST REAL WALK-AWAY SYSTEM! Alifax presents the real walk-away system for rapid bacterial culture and plate streaking of liquid samples. The system is composed of two units: Alfred 60AST and Sidecar. Thanks to the Light Scattering technology, Alfred 60AST detects the presence of bacteria and their drug resistance in a few hours with high sensitivity and specificity. Alfred 60AST monitors the growth phases of bacteria from the inoculum step into specific culture broths providing real time growth curves and quantitative bacterial results in CFU/ml. Broth turbidity level is detected by the McFarland Monitor and as the sample reaches the 0.5 McF it is buffered into the refrigerated area and then tested with a customised antibiotic panel. Sidecar is an automated streaking system able to store 240 Petri dishes and up to 12 different media. The streaked dishes are incubated on board at 37°C for the requested analysis time. In the main operating setting only the positive samples are plated automatically. Advantages · · · · · · · · Negative samples are reported in one day Significant reduction of streaked samples Saving materials and time for reading Different streaking patterns Incubation on board at 37°C Single sample management with customized analysis profile settings Automated barcode labelling for single plate Compatible with different primary disposable tubes WindowsTM operative System TESTS AND APPLICATIONS Urine culture 3 hours, cutoff 30.000 CFU/ml Residual Antimicrobial Activity (RAA) test Simultaneously to the culture test Human Biological Liquid Bacterial Culture 6 hours, cutoff <50 CFU/ml Bacteria Culture on special sample 6 hours, cutoff <50 CFU/ml MDRO culture screening Aerobics, Anaerobics and Fungi detection 48 hours for microbiological suitability tests Susceptibility testing with customised antibiotic panel for: · Urine · Human Biological Liquids · Positive Blood Culture · Isolated Colonies All the applications currently offered by Light Scattering technology are kept unchanged thus Bacterial Culture of Biological Liquids and MDRO screening results are available in 6 hours while Susceptibility testing results in 3 hours. Due to regulatory requirements, the products listed herein are available for sale in any relevant Country territory provided that they have been registered according to the applicable domestic law. The products listed herein may have incurred changes with respect to the last

Open the catalog to page 1
SIDECAR® - 2

FEATURES WORKING PROCEDURES Streaking of primary samples detected positive at Rapid Bacterial Culture Streaking of samples such as Urine, liquid swabs, other liquid samples in different primary disposable tubes Streaking of bacterial suspension from positive culture vial (URO-QUICK SCREENING KIT, HB&L culture kit, MDRO kit) a a an ui fo ete 28 Sh th ® rg liq s ex 24ab lyure ency mpl ts oo to re -sw po sorb r co en micr ed in ensu d ag ft ab an al ll fo re e of leas ling, ure ew So hr N ce d High n m an releas is re hand capt uret pe O ediu um imen sy ab for m e im ec for ea d sw able s nv...

Open the catalog to page 2

All ALIFAX catalogs and technical brochures

  1. I-DONE

    2 Pages

  2. ALICASE

    2 Pages

  3. ALIBOX

    8 Pages

  4. HB&L®

    2 Pages

  5. ALFRED 60AST

    2 Pages

  6. TEST 1

    2 Pages

  7. ROLLER 20 LC

    2 Pages

  8. ROLLER 20 PN

    2 Pages

  9. ROLLER 20 MC

    2 Pages

  10. PenOk

    1 Pages

  11. Penok Swab

    2 Pages

  12. SIDECAR

    2 Pages

  13. ESR LINE

    2 Pages

  14. HB&L

    2 Pages

  15. ALFRED

    2 Pages