Allengers, founded in 1987, is a leading Indian company specializing in medical diagnostic systems, with a presence in over 70 countries. The company focuses on providing innovative medical products and solutions across various fields, including radiology, cardiology, and more.
This manual offers safety instructions for operating the X-Ray system, stressing compliance with local regulations and preventing unauthorized access. It highlights warnings and cautions to avoid injury or damage.
The Allengers Cathlab Machine is a digital cardiovascular angio system for cardiac angiographies, valvuloplastic, and stenting, suitable for medical clinics and hospitals but not for mammography. It should be operated by trained professionals and is contraindicated during pregnancy.
The manual details safety hazards, including general, electrical, mechanical, radiation, and environmental safety, and provides emergency procedures and incident reporting guidelines.
Includes system specifications, control keys, operation modes, and instructions for starting studies, performing procedures, and acquiring images.
Guidelines for cleaning, disinfection, inspection, disposal, and security measures, including malware protection, are provided.
Lists product approvals, including certifications from the Atomic Energy Regulatory Board, CE, and ISO standards compliance.
Information on equipment labels and symbols is provided for proper understanding and operation.
Includes guidance on resolving common system issues efficiently.
The Cathlab machine supports comprehensive clinical coverage for fluoroscopic and radiographic applications, aiding in diagnosing coronary artery disease and evaluating heart functions.
Emphasizes the necessity of training for safe operation and warns against using incompatible parts.
Details emergency actions, including moving the patient table for access and using the emergency STOP button.
Guidelines for handling electrical components, grounding, and cleaning procedures are outlined.
Operators must avoid collisions and adhere to ALAP principles to minimize radiation exposure.
Proper disposal of harmful materials and precautions against using the system in explosive environments are emphasized.
Describes components like the Human Machine Interface, X-ray generator, and flat panel detector.
Details on ADRC modes, fluoro and cine modes, and DSA techniques for imaging.
Includes cleaning, disinfection, and inspection checklists, along with guidelines for consumable parts replacement.
Recommends a multi-layered security strategy and regular risk assessments.
Provides environmental requirements, transport and storage conditions, and IP ratings.
Describes methods for measuring X-ray tube voltage and current, and loading factors according to IEC standards.
Details setup for measuring dosimetric information and guidelines for different patient sizes.
Outlines compliance with international standards and warranty terms, including contact information for Allengers Medical Systems Ltd.
Series: Photon F65 (Mobile Cathlab) OPERATION / USER MANUAL MEDICAL SYSTEMS LTD. S.C.O. 212-214, SEC. 34-A, CHANDIGARH (INDIA) TEL.: +91-172-6618000-99 FAX: +91-172-2621912 E-mail: [email protected] Website: www.allengers.com Easy Medical Device CommV, (Mr. Monir El Azzouzi) Dendermondestraat 40-44 2018 Antwerpen, email id: [email protected] Website: www.easymedicaldevice.com
Open the catalog to page 1User Manual We thank you for purchase of Allengers Life HP X-Ray Machine. This machine is type approved for Mechanical, Electrical & Radiation safety standards by following regulatory boards: Atomic Energy Regulatory Board (AERB) –14-TA19224: Approved for meeting Radiation Safety Standards. CE Certified – CE 663857: Approved for meeting International Safety Standards. ISO 9001:2015 & EN ISO 13485:2016 Approved for meeting Quality Management System Requirements.
Open the catalog to page 2User Manual AMSL/UM/ALLENGERSLIFEHP/PHOTONF 65/33 Rev. 07, Effective Date 10.03.2025
Open the catalog to page 3User Manual 1. Manual Revision History Revision Change Description Initial Release Update Annex A as per Labeling Loading Factor & Dosimetric Information Updated Removed CE marking & EU Representative address from the device and also update the compliance table Add CE marking along with EU Representative Removed CE marking & EU Representative address Address Notify body identification number change from BSI from the device and also update the compliance table (2797) to DQS (0297) EU Representative Address change
Open the catalog to page 5User Manual 2. Introduction 2.1 About Us Established in 1987, Allengers is a leading Indian name in the realm of medical diagnostic system & IT solutions in more than 70 countries worldwide. With a vision to develop strategic long term relationships with clients, we are committed to bringing to life; medical products & solutions and serving the humanity by delivering excellent patient care. An Indian market share of more than 35%, ever-rising exports to foreign governments & clients, innumerable national & international awards, all bear a testimony to the immense customer satisfaction our offerings...
Open the catalog to page 6User Manual 2.3 Intended Use The Allengers Cathlab Machine is Digital Cardiovascular Angio System with HF X-Ray Generator for applications in Cardiac Angiographies, Valvuloplastic & Stenting. Cathlab (X-Ray) Machine is high power X-Ray equipment used in catheterization labs. This equipment uses high power X-Ray pulses and digital imaging system including Dynamic Flat panel detector to visualize the vascular structures of human body. It is designed for use in medical clinic, hospital & veterinary application. This Machine should be handled by persons who have been briefed in its professional handling...
Open the catalog to page 7User Manual Clinical Benefit The clinical benefit of the Cathlab machine is to help healthcare professionals by providing full clinical coverage of Fluoroscopic & radiographic applications. Multiple movements can be performed on a C-arm system around the patient to facilitate imaging from multiple different angle projections. Cathlab machine is used to: • Confirm the presence of coronary artery disease, valve disease or disease of Aorta. • Evaluate heart muscle functions. • Determine the need for further treatment (Eg. Interventional procedure or coronary artery bypass graft or surgery required)...
Open the catalog to page 8User Manual 3. Safety Hazards CAUTION: Any kind of service or maintenance of equipment is prohibited while machine is in use with a patient or power on condition. 3.1 General Safety Allengers products are designed to meet stringent safety standards. All medical electrical systems require proper installation, operation, and maintenance to ensure personal safety and correct operation. WARNING Do not use the system until you have read and understood all safety directions, emergency procedures, warnings, and cautions contained in this manual, and observed all danger notices and safety markings on...
Open the catalog to page 9User Manual 3.2.3 Emergency Stop To stop all system movements during an emergency in the examination room, press the emergency STOP button. The emergency STOP button is located on the foot end control panel as well as on the top of touch monitor. Emergency Stop Buttons (Red) Position of Emergency Stop Switch To restart the system after emergency stop, Step 1: Turn OFF the system completely Turn off the PC, Pull down the MCB of x-ray generator and press the power OFF button (mounted on wall). Step 2: Turn ON the System Press the ON button (on wall), Pull up the MCB of x-ray generator and then...
Open the catalog to page 10User Manual 3.5 Electrical Safety The following electrical safety guidelines must be followed to avoid electric shock or serious injury to operator and patient and to avoid system malfunction: Voltages Dangerous electrical voltages are present within the system. Covers or cables should only be removed by qualified and authorized service personnel. Do not touch electrical connectors on the patient table or on the monitor ceiling suspension while simultaneously touching the patient. Connector contact pins may carry low voltages that are safe to touch, but that may be harmful to the patient. Earthing...
Open the catalog to page 11User Manual 3.5.1 First Aid in Case of Electric Shock ➢ Switch OFF the Power Supply: If this is not possible, protect yourself with dry insulating material and pull the victim clear off the conductor. Do not touch the victim with your bare hands until he/she is clear off the conductor. ➢ Place the victim in supine position. ➢ If the jaw is rigid, try to force the mouth open by putting pressure on the gum behind the last molar tooth of the lower jaw. When the upper air passage is cleared, tilt the head backward and force the jaw forward from the angles of the jaw in front of the ears. This would...
Open the catalog to page 12User Manual ^ Never radiate unless absolutely necessary and only radiate for as short a time as possible. > The radiation exposure to the patient should be the minimum exposure required to produce images of good diagnostic quality. Use radiation with care, caution and at a rate which is ALAP - ‘As Low As Possible’. > Select the appropriate patient type. > Gonadal shielding of not less than 0.25 mm lead equivalent shall be used for patients who have not passed their reproductive age during radiographic procedures in which gonads are under primary beam, except, in cases where shielding would interfere...
Open the catalog to page 1385 Pages
161 Pages
135 Pages
145 Pages
8 Pages
3 Pages
8 Pages
8 Pages
16 Pages
12 Pages
2 Pages
8 Pages
8 Pages
40 Pages
6 Pages