Proxima CS 3D

Proxima CS 3D
1 / 161 PagesView full catalog

Proxima CS 3D

Product catalog summary
Introduction
The manual provides detailed guidance on the operation, maintenance, and safety of the Allengers Pride HP Proxima CS 3D Cathlab system, emphasizing the importance of following instructions for safe and effective use.
Company and Customer Responsibility
Allengers Medical Systems Ltd. ensures the safety and performance of the equipment if assembly, modifications, and repairs are conducted by authorized personnel. Users must maintain a satisfactory maintenance schedule and adhere to instructions for use and storage of accessories.
Safety Hazards
The manual outlines safety precautions, including general safety, emergency procedures, and specific measures for laser targeting devices, electrical, mechanical, radiation, electromagnetic disturbances, environmental, explosion, and fire safety.
System Configuration and Overview
Details the mechanical positioning of system components in the examination room and provides an overview of the console room and X-ray indicators.
Operation Procedures
Instructions for starting and stopping the system, managing power failures, and using software applications are provided, including guidance on creating new patient records and preparing the system for procedures.
Performing Procedures
Includes details on operation modes, starting procedures, using collimator shutters, sterile covers, acquiring images, and ending procedures.
Maintenance
Guidelines for cleaning, disinfection, and system inspection are provided to ensure the longevity and safety of the equipment.
Disposal and Security
Instructions for disposing of the system and ensuring security, including customer responsibilities and malware protection, are outlined.
Technical Information
Environmental requirements, technical specifications, and X-ray safety information are detailed.
Labels and Symbols
The manual explains the labels and symbols used on the equipment for easy identification and understanding.
Troubleshooting and Regulatory Information
Common troubleshooting steps and regulatory information are provided to assist users in resolving issues and understanding compliance requirements.
Product Approvals and Intended Use
The Allengers Pride HP X-Ray Machine is approved by relevant safety boards and is intended for specific cardiovascular procedures, with a minimum service life of 10 years.
Safety and Training
Operators must be adequately trained and qualified, understanding safety information and emergency procedures.
Emergency Procedures and Incident Reporting
In emergencies, the system can be reset for patient access. Serious incidents must be reported to the manufacturer and authorities.
Laser Targeting Devices and Electrical Safety
Guidelines include avoiding direct eye exposure to lasers and ensuring proper grounding and cable management for electrical safety.
Mechanical and Radiation Safety
Operators must follow standard layout plans to avoid collisions, and adhere to ALAP principles to minimize radiation exposure.
Environmental and Fire Safety
Proper disposal of harmful materials is necessary, and specific fire safety procedures are outlined.
System Components and Controls
Includes details on the ceiling suspended gantry, tube head assembly, emergency stop switch, foot switch, and control panel functions.
Software Overview
The Synergy FP software is used for digital fluoroscopy and image processing, requiring proper training before use.
Image Manipulation and Reporting
Features include image viewer settings, ECG adjustments, and tools for image diagnosis and reporting.
Technical Specifications
Includes environmental requirements, power specifications, and detailed technical information on system components.
Compliance and Warranty Information
The equipment complies with international standards and includes a warranty against defects for a specified period.
See more

Catalog excerpts

Proxima CS 3D-1

Series: Proxima CS 3D (Fixed Cathlab) OPERATION / USER MANUAL MEDICAL SYSTEMS LTD. S.C.O. 212-214, SEC. 34-A, CHANDIGARH (INDIA) TEL.: +91-172-6618081, 6618082 FAX: +91-172-2621912 E-mail: [email protected] Website: www.allengers.com Easy Medical Device CommV, (Mr. Monir El Azzouzi) Dendermondestraat 40-44 2018 Antwerpen, email id: [email protected] Website: www.easymedicaldevice.com

 Open the catalog to page 1
Proxima CS 3D-2

User Manual Word of Thanks We appreciate your business and now that you are a valuable customer of Allengers Medical Systems Ltd., we would like to hear from you, because your feedback or suggestions are important for us. If you have comments, please don’t hesitate to contact us. Copyright © Allengers owns all rights of this unpublished work and has the right to maintain this work as confidential. This publication is to be used solely for the purposes of reference, operation, maintenance and repair of Allengers Cathlab Machine. Allengers owns all rights to this work. Those having access to this...

 Open the catalog to page 2
Proxima CS 3D-3

User Manual Please go through the entire instruction manual carefully before operating this device. This machine is type approved for mechanical, electrical & radiation safety standards by regulatory boards. Installation, adjustments, calibration and repair of machine shall be carried out by person authorized by Allengers Medical System Ltd. This manual may not be reproduced, in whole or in part, without the written permission of Allengers Medical Systems Ltd. (AMSL). The material in this manual is provided for informational purposes only and due to continuous improvement in product AMSL/UM/ALLENGERS...

 Open the catalog to page 3
Proxima CS 3D-4

User Manual AMSL/UM/ALLENGERS PRIDE HP/PROXIMA CS 3D/53 Rev. 02, Effective Date 10.03.2025

 Open the catalog to page 4
Proxima CS 3D-6

User Manual We thank you for purchase of Allengers Pride HP X-Ray Machine. This machine is type approved for Mechanical, Electrical & Radiation safety standards by following regulatory boards: Atomic Energy Regulatory Board (AERB) – 14-TA23026: Approved for meeting Radiation Safety Standards. CE Certified – CE 663857: Approved for meeting International Safety Standards. ISO 9001:2015 & EN ISO 13485:2016 Approved for meeting Quality Management System Requirements. For registering your equipment/institute with the Atomic Energy Regulatory Board (AERB) please log on to www.aerb.gov.in and click...

 Open the catalog to page 6
Proxima CS 3D-7

User Manual 1. Manual Revision History Revision Date Description of changes 21.01.2025 Notify body identification number change from 10.03.2025 EU Representative address change AMSL/UM/ALLENGERS PRIDE HP/PROXIMA CS 3D/53 Rev. 02, Effective Date 10.03.2025

 Open the catalog to page 7
Proxima CS 3D-8

User Manual Established in 1987, Allengers is a leading Indian name in the realm of medical diagnostic system & IT solutions in more than 70 countries worldwide. With a vision to develop strategic long term relationships with clients, we are committed to bringing to life; medical products & solutions and serving the humanity by delivering excellent patient care. An Indian market share of more than 35%, ever-rising exports to foreign governments & clients, innumerable national & international awards, all bear a testimony to the immense customer satisfaction our offerings deliver. Guided by our...

 Open the catalog to page 8
Proxima CS 3D-9

User Manual 2.3 Intended Use The Allengers Cathlab Machine is Digital Cardiovascular Angio System with HF X-Ray Generator for applications in Cardiac Angiographies, Valvuloplastic & Stenting. Cathlab (X-Ray) Machine is high power X-Ray equipment used in catheterization labs. This equipment uses high power X-Ray pulses and digital imaging system with dynamic flat panel detector to visualize the vascular structures of human body. This Machine should be handled by persons who have been briefed in its professional handling and who have familiarized themselves with the product by means of user manual....

 Open the catalog to page 9
Proxima CS 3D-10

User Manual Clinical Benefit The clinical benefit of the Cathlab machine is to help healthcare professionals by providing full clinical coverage of Fluoroscopic & radiographic applications. Multiple movements can be performed on a C-arm system around the patient to facilitate imaging from multiple different angle projections. Cathlab machine is used to: • Confirm the presence of coronary artery disease, valve disease or disease of Aorta. • Evaluate heart muscle functions. • Determine the need for further treatment (Eg. Interventional procedure or coronary artery bypass graft or surgery required)...

 Open the catalog to page 10
Proxima CS 3D-11

User Manual 3. Safety Hazards CAUTION: Any kind of service or maintenance of equipment is prohibited while machine is in use with a patient or power on condition. 3.1 General Safety Allengers products are designed to meet stringent safety standards. All medical electrical systems require proper installation, operation, and maintenance to ensure personal safety and correct operation. WARNING Do not use the system until you have read and understood all safety directions, emergency procedures, warnings, and cautions contained in this manual, and observed all danger notices and safety markings on...

 Open the catalog to page 11
Proxima CS 3D-12

User Manual 3.2.2 Cardiopulmonary Resuscitation In the event of a clinical emergency involving a patient requiring cardiopulmonary resuscitation (CPR), directly start the CPR procedure. CPR is possible in any tabletop position. However, to make CPR easier to perform, follow this procedure. 1. 2. 3. 4. 5. Move the gantry away from the patient. Ensure that there is all-round access to the patient. Move the patient above the table base to reduce the effect of flexing of the tabletop. Adjust the tabletop up/down movement to an appropriate height. Perform CPR. 3.2.3 Emergency Stop To stop all system...

 Open the catalog to page 12
Proxima CS 3D-13

User Manual 3.3 Reporting a Serious Incident If a serious incident occurs in relation to the device, it should be reported to the manufacturer and the competent authority of the country where you are located. For contact details, see Contacting the Manufacturer. A serious incident means any incident that directly or indirectly led to, might have led to, or in case of recurrence, could lead to, any of the following: • The death of a patient, user, or other person. • The serious deterioration of the state of health (temporary or permanent) of a patient, user, fetus, or other person. • A serious...

 Open the catalog to page 13