Proxima CS 3D

Proxima CS 3D
1 / 85 PagesView full catalog

Proxima CS 3D

Product catalog summary
Introduction
This user manual is for the Allengers Pride HP Proxima CS Fixed Cathlab, providing essential information for operation, maintenance, and safety. It is intended for trained personnel authorized by Allengers Medical Systems Ltd.
Company and Customer Responsibility
Allengers ensures safety and performance if the equipment is handled by authorized personnel. Customers must maintain the equipment and follow usage instructions to prevent failures and health hazards.
Safety Hazards
The manual outlines safety hazards including electrical, mechanical, radiation, and environmental safety, along with emergency procedures and incident reporting instructions.
System Configuration and Overview
Describes the mechanical positioning of system components and the console room setup.
Operation Procedures
Details instructions for system operation, including patient positioning, system preparation, and image acquisition.
Maintenance
Guidelines for cleaning, disinfection, and system inspection to ensure optimal performance and longevity.
Technical Information
Includes environmental requirements, technical specifications, and X-ray safety information to ensure compliance with safety standards.
Regulatory Information
The equipment is approved by the Atomic Energy Regulatory Board and CE certified, meeting international safety standards.
Warranty
Details the terms and conditions of the warranty provided by Allengers.
Quality Management System Approvals
The product meets ISO 9001:2015 and EN ISO 13485:2016 standards.
Product and System Approvals
The EU Authorized Representative is Easy Medical Device CommV, Belgium.
Manual Revision History
Includes initial release and subsequent updates.
General Safety and Awareness
Training is provided at system handover, and operators must be trained and understand safety instructions.
Electrical Safety
Ensure independent grounding and follow IEC 60601-1 standards. First aid for electric shock is outlined.
Mechanical Safety
Install equipment according to standard layout to avoid collisions. The system has a Smart Collision Avoidance System.
Radiation Safety
Follow ALAP principles to minimize exposure. Use protective measures and ensure doses do not exceed limits.
Environmental Safety
Dispose of harmful materials according to local regulations and use equipment within rated conditions.
System Configuration and Overview
Includes components like X-ray tube, flat panel detector, and monitors. Describes mechanical movements and controls.
Functional Description of Touch Screen Module
Includes image viewer, control panel, and various settings for image acquisition and processing.
Maintenance
Includes cleaning and disinfection procedures, daily, weekly, and monthly checklists, and disposal and transfer guidelines.
Technical Specifications
Details environmental requirements, IP ratings, X-ray system configuration, and power line requirements.
Warranty Information
Equipment is warranted against defects for 12 months from installation or 15 months from dispatch.
See more

Catalog excerpts

Proxima CS 3D-1

Series: Proxima CS (Fixed Cathlab) OPERATION / USER MANUAL OUR NEAREST SERVICE CENTRE MEDICAL SYSTEMS LTD. S.C.O. 212-214, SEC. 34-A, CHANDIGARH (INDIA) TEL.: +91-172-6618000-99 FAX: +91-172-2621912 E-mail: [email protected] Website: www.allengers.com You can register your complaints at: E-mail : [email protected]

 Open the catalog to page 1
Proxima CS 3D-2

User Manual Word of Thanks We appreciate your business and now that you are a valuable customer of Allengers Medical Systems Ltd., we would like to hear from you, because your feedback or suggestions are important for us. If you have comments, please don’t hesitate to contact us. Copyright © Allengers owns all rights of this unpublished work and has the right to maintain this work as confidential. This publication is to be used solely for the purposes of reference, operation, maintenance and repair of Allengers Cathlab Machine. Allengers owns all rights to this work. Those having access to this...

 Open the catalog to page 2
Proxima CS 3D-3

User Manual Please go through the entire instruction manual carefully before operating this device. This machine is type approved for mechanical, electrical & radiation safety standards by regulatory boards. Installation, adjustments, calibration and repair of machine shall be carried out by person authorized by Allengers Medical System Ltd. This manual may not be reproduced, in whole or in part, without the written permission of Allengers Medical Systems Ltd. (AMSL). The material in this manual is provided for informational purposes only and due to continuous improvement in product AMSL/UM/ALLENGERS...

 Open the catalog to page 3
Proxima CS 3D-4

User Manual AMSL/UM/ALLENGERS PRIDE HP/PROXIMA CS/53 Rev. 07, Effective Date 10.03.2025 Page | 4

 Open the catalog to page 4
Proxima CS 3D-5

User Manual AMSL/UM/ALLENGERS PRIDE HP/PROXIMA CS/53 Rev. 07, Effective Date 10.03.2025

 Open the catalog to page 5
Proxima CS 3D-6

User Manual We thank you for purchase of Allengers Pride HP X-Ray Machine. This machine is type approved for Mechanical, Electrical & Radiation safety standards by following regulatory boards: Atomic Energy Regulatory Board (AERB) – 14-TA23026: Approved for meeting Radiation Safety Standards. CE Certified – CE 663857: Approved for meeting International Safety Standards. ISO 9001:2015 & EN ISO 13485:2016 Approved for meeting Quality Management System Requirements. For registering your equipment/institute with the Atomic Energy Regulatory Board (AERB) please log on to www.aerb.gov.in and click...

 Open the catalog to page 6
Proxima CS 3D-7

User Manual 1. Manual Revision History Revision Change Description Initial Release Detector Change & Software Update Loading Factor & Dosimetric Information Updated Removed CE marking & EU Representative address from the device and also update the compliance table Add CE marking along&with Representative Removed CE marking EU EU Representative address address from the device and also update the compliance table Notify body identification number change from BSI (2797) to DQS (0297) EU Representative Address change AMSL/UM/ALLENGERS PRIDE HP/PROXIMA CS/53 Rev. 07, Effective Date 10.03.2025

 Open the catalog to page 7
Proxima CS 3D-8

User Manual Established in 1987, Allengers is a leading Indian name in the realm of medical diagnostic system & IT solutions in more than 70 countries worldwide. With a vision to develop strategic long term relationships with clients, we are committed to bringing to life; medical products & solutions and serving the humanity by delivering excellent patient care. An Indian market share of more than 35%, ever-rising exports to foreign governments & clients, innumerable national & international awards, all bear a testimony to the immense customer satisfaction our offerings deliver. Guided by our...

 Open the catalog to page 8
Proxima CS 3D-9

User Manual 2.3 Intended Use The Allengers Cathlab Machine is Digital Cardiovascular Angio System with HF X-Ray Generator for applications in Cardiac Angiographies, Valvuloplasty & Stenting. Cathlab (X-Ray) Machine is high power X-Ray equipment used in catheterization labs. This equipment uses high power X-Ray pulses and digital imaging system with dynamic flat panel detector to visualize the vascular structures of human body. This Machine should be handled by persons who have been briefed in its professional handling and who have familiarized themselves with the product by means of user manual....

 Open the catalog to page 9
Proxima CS 3D-10

User Manual WARNING This X-Ray system must be used in strict compliance with the safety instructions contained in this manual and must not be used for purposes other than those for which it is intended. Clinical Benefit The clinical benefit of the Cathlab machine is to help healthcare professionals by providing full clinical coverage of Fluoroscopic & radiographic applications. Multiple movements can be performed on a C-arm system around the patient to facilitate imaging from multiple different angle projections. Cathlab machine is used to: • Confirm the presence of coronary artery disease, valve...

 Open the catalog to page 10
Proxima CS 3D-11

User Manual 3. Safety Hazards CAUTION: Any kind of service or maintenance of equipment is prohibited while machine is in use with a patient or power on condition. 3.1 General Safety Allengers products are designed to meet stringent safety standards. All medical electrical systems require proper installation, operation, and maintenance to ensure personal safety and correct operation. WARNING Do not use the system until you have read and understood all safety directions, emergency procedures, warnings, and cautions contained in this manual, and observed all danger notices and safety markings on...

 Open the catalog to page 11
Proxima CS 3D-12

User Manual 3. Press the L-Arm movement enable button on foot end control panel and then move the L-Arm to home position by using CW /CCW rotation switch. 4. Move the patient table away from gantry by using the magnet release switches (available on table near the foot end control panel) 3.2.2 Cardiopulmonary Resuscitation In the event of a clinical emergency involving a patient requiring cardiopulmonary resuscitation (CPR), directly start the CPR procedure. CPR is possible in any tabletop position. However, to make CPR easier to perform, follow this procedure. 1. 2. 3. 4. 5. Move the gantry away...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.