Introduction
Chemetron has been a leader in suction regulators for over 40 years, offering the Vacutron line known for its safety and performance features. The Vacutron provides advantages such as superior patient safety, easy sterilization, model-specific labeling, and a glow-in-the-dark gauge.
Key Features
  • Superior Patient Safety: Features a secondary internal vacuum relief valve to prevent excessive vacuum pressure.
  • Simple Sterilization: Can be sterilized with isopropyl alcohol.
  • Model-Specific Labeling: Color-coded labels for easy identification.
  • Glow-in-the-Dark Gauge: Standard feature for easy readability.
Models and Specifications
  • Continuous Model: Designed for constant vacuum, with a safety relief valve limiting vacuum to 320 mm Hg. Dimensions: 6.8" H x 2.65" W x 4.07" D. Warranty: 10 years.
  • Pediatric Continuous Model: Limits vacuum to 140 mm Hg for pediatric use. Same dimensions and warranty as the continuous model.
  • Low Vacuum (Neonatal) Model: Limits vacuum to 100 mm Hg for neonatal use. Same dimensions and warranty.
  • High Vacuum Model: For procedures requiring vacuum pressures over 300 mm Hg. No safety relief valve. Same dimensions and warranty.
  • Surgical Model: For surgical suites, with vacuum limited to 320 mm Hg in regulated mode. Same dimensions and warranty.
  • Continuous/Intermittent Model: Supports constant or intermittent suction, with dual safety relief valves. Same dimensions and warranty.
  • Pediatric Continuous/Intermittent Model: For pediatric use, with dual safety relief valves. Same dimensions and warranty.
Configuration and Accessories
Each model can be configured with various fittings for compatibility with medical facility fixtures. A configuration table is provided for selecting the appropriate model and fittings.
Product Overview
The document details specifications and configurations for suction regulators and collection canisters used in medical settings, including pediatric continuous/intermittent suction regulators, intermittent suction regulators, disposable collection canisters, and reusable collection bottle assemblies.
Specifications
  • Vacuum Gauge Scale: 0-150 mm Hg in 5 mm Hg increments.
  • Dimensions: 6.8" H x 2.65" W x 4.07" D (174 mm x 67 mm x 104 mm).
  • Weight: 1.3 lbs. (0.59 kg).
  • Warranty: 10 years.
Intermittent Suction Regulators
These regulators deliver intermittent vacuum only, ensuring constant suction is never delivered. They include an internal safety relief valve limiting vacuum to 170 mm Hg and a superior regulation mechanism for stable settings.
Disposable Collection Canisters
Available in various configurations, these canisters feature a unique filter and self-sealing material to improve flow and prevent fluid entry into the suction regulator. They come with DISS connections for easy attachment to wall suction regulators.
Reusable Collection Bottle Assemblies
Available in glass or polycarbonate, these include a positive shut-off cap and float assembly to prevent fluid carryover. Offered in sizes of 2800 ml, 1200 ml, 600 ml, and 473 ml.
Accessories
Includes disposable hydrophobic bacteria filters to protect the vacuum system from contamination, and various bottle holders and carriers for ease of use.
Configuration and Ordering
Configuration tables are provided for selecting the appropriate fittings and connections for different models, along with part numbers for ordering.
Contact Information
For more information, contact Allied Healthcare Products via phone or visit their website.
See more

Catalog excerpts

Vacutron® Suction Regulators-1

Vacutron Suction Regulators ® & Accessories Guide

 Open the catalog to page 1
Vacutron® Suction Regulators-2

Vacutron® Suction Regulators by Chemetron® Chemetron has been a leader in suction regulators for more than 40 years. The Vacutron line offers safety and performance features unlike any other regulator on the market. Vacutron provides four distinct advantages over other suction regulators.  Superior Patient Safety Vacutron suction regulators have a secondary internal vacuum relief valve. This valve ensures that under no circumstance, i.e. component failure, can the vacuum pressure delivered to the patient exceed a pre-set safe level so the patient is not inadvertently exposed to the full line...

 Open the catalog to page 2
Vacutron® Suction Regulators-3

Vacutron® Suction Regulators by Chemetron® Easy access mode selection knob gives instant access to regulated, intermittent and full-line modes, depending on the model. High-impact polycarbonate case for strength and durability. Color-coded glow-in-the-dark analog gauge provides easy readability under typical hospital lighting conditions. Oversized vacuum regulating knob ensures precise vacuum control. Weight-bearing brass posts prevent case from cracking. A full line of inlet and outlet fittings ensures compatibility with existing fixtures in any medical facility. Model-specific color-coded label...

 Open the catalog to page 3
Vacutron® Suction Regulators-4

Continuous Model The continuous suction regulator is designed to deliver constant vacuum for general suction procedures, including routine maintenance of the patient airway, oropharyngeal and endotracheal suctioning. Key Features  Internal safety relief valve limits the maximum vacuum level to 320 mm Hg in the event of regulator failure or inaccuracy  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source vacuum  ISO configurations available Specifications Operating Modes: OFF and Regulated Regulated Vacuum Range: 0-300 mm Hg Safety Relief Valves: 1 @...

 Open the catalog to page 4
Vacutron® Suction Regulators-5

Pediatric Continuous Model The pediatric continuous suction regulator is designed to deliver constant vacuum for general suction procedures on pediatric patients, including routine maintenance of the airway, oropharyngeal and endotracheal suctioning. Key Features  Internal safety relief valve limits the maximum vacuum level to 140 mm Hg in the event of regulator failure or inaccuracy  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source vacuum  ISO configurations available Specifications Operating Modes: OFF and Regulated Regulated Vacuum Range: 0-130...

 Open the catalog to page 5
Vacutron® Suction Regulators-6

Low Vacuum (Neonatal) Continuous Model The low vacuum continuous suction regulator is designed to deliver constant vacuum for general suction procedures on neonatal patients, including routine maintenance of the airway, oropharyngeal and endotracheal suctioning. Key Features  Internal safety relief valve limits the maximum vacuum level to 100 mm Hg in the event of regulator failure or inaccuracy  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source vacuum  ISO configurations available Specifications Operating Modes: OFF and Regulated Regulated Vacuum...

 Open the catalog to page 6
Vacutron® Suction Regulators-7

High Vacuum Continuous Model The high vacuum suction regulator is designed for procedures that require constant vacuum pressures in excess of 300 mm Hg. There are two operational modes: regulated suction and full line. Regulated suction allows the clinician to set the vacuum level between 0 and the vacuum line pressure. On full line mode, the vacuum pressure delivered is unregulated and equal to the vacuum line pressure. Key Features  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source vacuum  ISO configurations available Specifications Operating Modes:...

 Open the catalog to page 7
Vacutron® Suction Regulators-8

Surgical Continuous Model The surgical suction regulator is designed for use in surgical suites. There are two operational modes: regulated vacuum and full line. Regulated suction allows the clinician to set the vacuum level between 0 and 300 mm Hg. On full line mode, the vacuum pressure delivered is unregulated and equal to the vacuum line pressure. Key Features  Internal safety relief valve limits the maximum vacuum level on regulated mode to 320 mm Hg in the event of regulator failure or inaccuracy  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source...

 Open the catalog to page 8
Vacutron® Suction Regulators-9

Continuous/Intermittent Model The continuous/Intermittent suction regulator is designed to support a variety of procedures requiring constant or intermittent suction. Constant suction is used primarily to maintain a patient’s airway, while intermittent suction is used for drainage procedures. Key Features  Dual safety relief valves limit the maximum vacuum level on both constant and intermittent modes in the event of regulator failure or inaccuracy  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source vacuum  ISO configurations available Specifications...

 Open the catalog to page 9
Vacutron® Suction Regulators-10

Pediatric Continuous/Intermittent Model The pediatric continuous/intermittent suction regulator is designed to support a variety of procedures requiring constant or intermittent suction on pediatric patients. Constant suction is used primarily to maintain the patient airway, while intermittent suction is used for drainage procedures. Key Features  Dual safety relief valves limit the maximum vacuum level on both constant and intermittent modes in the event of regulator failure or inaccuracy  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source vacuum...

 Open the catalog to page 10
Vacutron® Suction Regulators-11

Intermittent Model Intermittent suction regulators are designed to deliver intermittent vacuum only. This regulator is used when clinicians want to ensure that constant suction is never delivered. Key Features  Internal safety relief valve limits the maximum vacuum level to 170 mm Hg in the event of regulator failure or inaccuracy  Superior regulation mechanism ensures stable vacuum settings even with fluctuations in source vacuum  ISO configurations available Specifications Operating Modes: OFF and Intermittent Regulated Vacuum Range: 0-150 mm Hg Cycle Times: 17 seconds of suction followed...

 Open the catalog to page 11

All Allied Healthcare Products catalogs and technical brochures

  1. EPV100

    2  Pages

  2. EPV200

    1  Page

  3. Carbolime®

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.