The ALN OPTIONAL VENA CAVA FILTERS
1 / 12Pages

Catalog excerpts

The ALN OPTIONAL VENA CAVA FILTERS - 1

OPTIONAL VENA CAVA FILTERS & The ALN Removal and/or Repositioning Kits

Open the catalog to page 1
The ALN OPTIONAL VENA CAVA FILTERS - 2

The ALN Optional Vena Cava Filters

Open the catalog to page 2
The ALN OPTIONAL VENA CAVA FILTERS - 4

THE ALN OPTIONAL VENA CAVA FILTERS Permanent and/or temporary intended to be retrievable at any time* Easy to implant Excellent corrosion resistance Unique design Upper level for anchoring Lower level for centering  Different length of the legs to minimize the risk of legs interlacing  Legs are at two different levels: Upper level for anchoring (6 shorter legs) Lower level for centering (3 longer legs)  Introducer sheath= low profile 7F Retrieval sheath= low profile 9F Legs’ configuration minimizes the risk of cava penetration * please refer to our local distributor for retrieval approved

Open the catalog to page 4
The ALN OPTIONAL VENA CAVA FILTERS - 5

The only retrievable IVC filters > manufactured in stainless steel > approved with an indicated IVC diameter up to 32 mm (CE Mark) The choice is yours! The ALN Vena Cava Filter with hook can be removed using one of the ALN Removal Kits or using a lasso (Only by jugular approach) ALN Filter with Hook more options to retrieve the filter

Open the catalog to page 5
The ALN OPTIONAL VENA CAVA FILTERS - 6

THE ALN OPTIONAL VENA CAVA FILTERS

Open the catalog to page 6
The ALN OPTIONAL VENA CAVA FILTERS - 7

THE ALN VENA CAVA FILTERS Removal and/or Repositioning Kits Unique 2 in 1 RS ALN vena cava removal and/or repositioning kits Only by jugular approach Pincer specially designed to catch the apex of the filter Ability to change the angle of the pincer

Open the catalog to page 7
The ALN OPTIONAL VENA CAVA FILTERS - 8

The ALN OATF Optional Vena Cava Filter Just like the original, talented and reliable The ALN OATF Optional Vena Cava Filter with and without hook Based on the expertise and experience of ALN The only optional IVC Filter in Stainless steel without welding points: 3T MRI Compatible 4 approaches The only Optional IVC Filter approved to be implanted in patient whose vena cava diameter is less than or equal to 32 mm ^Enhanced stability with its 3 anti-tilting legs

Open the catalog to page 8
The ALN OPTIONAL VENA CAVA FILTERS - 9

A design with an unique technology: legs anchoring legs Optimal Design Anti-tilting legs for an optimum centering centering legs Anchoring legs with an anti-transfixion loop to minimize the risk of cava penetration Centering legs The ALN OATF optional IVC Filter with hook can be removed with one of our three extraction kits and/or a lasso THE ALN OATF OPTIONAL VENA CAVA FILTER

Open the catalog to page 9
The ALN OPTIONAL VENA CAVA FILTERS - 10

The mean interval between implantation and retrieval was 25.6 months (range, 14.8- - 40.8 months), and extractions were performed on eight patients who had received a filter at least 2 years earlier. The longest dwell time was 40 months. All filters were extracted successfully without complications. Conclusions: Optional ALN filter retrievals can be performed safety after more than 1 year following implantation. “Successful retrieval of 29 ALN Inferior Vena Cava Filters of 25.6 Months after placement.” Olivier Pellerin, MD - Massimiliano di Primio, MD -Olivier Sanchez, MD, PhD - Guy Meyer,...

Open the catalog to page 10
The ALN OPTIONAL VENA CAVA FILTERS - 12

ALN S.A.R.L. LEGAL MANUFACTURER Route de la gare 20240 GHISONACCIA FRANCE MANUFACTURING SITE 589, Chemin du Niel 83230 BORMES LES MIMOSAS FRANCE Tel. +33 (0)4 94 01 05 01 Q Fax. +33 (0)4 94 01 09 01 contact@aln2b.com W www.aln2b.com #

Open the catalog to page 12