Quick lock lid Lid interlock Light lid -up -down
Open the catalog to page 1
★Quick Lock Lid By the central lock lever, you can easily lock the lid with fingertip. The lid is lightened up and down by the automatic hinge. Even if you lose hold of the lid, it keeps stopped at the same position. ★Lid Interlock The lid is locked reliably during operation and till cooling down to the safe temperature (801C- ■ - adjustable by parameter). ★Electro Mechanical Lock This function brings more safety to operator by locking the lid at the power failure or in the power OFF, to prevent operator from contamination by contacting un-sterilized objects carelessly. Locking is released...
Open the catalog to page 2
© Pressure gauge © Temperature display ® Time display ® Start key Option ® Object temp, key OPERATION PATTERNS It can be chosen from 3 patterns (-DP:5 patterns) according to your purposes. Once changed the values are stored, even if the power is switched off. Dissoving of Culture medium© C : Heating / Warming TEMP. STER. WARM A Caution If a lot of materials difficult of air-exhaust, such as many small containers in sterilization bags, are sterilized at usable maximum temperature, pressure inside the chamber must increase and the over pressure detector may operate. Then, it is requested to...
Open the catalog to page 3
LOADING CAPACITY FOR LABORATORY FLASKS Round flasks Dimension
Open the catalog to page 4
| Object Temperature Sensor (For reliable sterilization) Object temperature will come up more slowly than temperature in the chamber,so sterilization time be added delay time to set time. It aids reliable sterilization that the timer begins to move only after the temperature measured by the object temperature reaches the set temperature. Necessaries for objects which prevent penetration of steam. It will be able to add on later. Chamber temperature- Object temperature--- Normal operation DELAY TIME | Automatic Water Supply (To save your manual water supply) In stead of troublesome check and...
Open the catalog to page 5
Autoclave for Laboratory use vL/vL'Ur series Model •Please specify the voltage when you order. •Specifications subject to change without notice for improvement. ALP Co.,Ltd. 3-3-10, Midorigaoka, Hamura-shi Tokyo 205-0003, Japan TEL.81 -42-579-0531 FAX.81 -42-579-0533 E-mail: alpco@wonder.ocn.ne.jp URL: http://www.alpco.co.jp
Open the catalog to page 6All ALP Co. catalogs and technical brochures
-
TR series
2 Pages
-
MC series
6 Pages
-
MC-3032 series
6 Pages
-
KT-40 series
4 Pages
-
KT series
6 Pages
-
Personal Autoclave
2 Pages
-
KY series
2 Pages
-
KMD series
2 Pages
-
RT/ST series
4 Pages
-
RY/SY series
4 Pages
-
GT series
2 Pages
-
DCL/DCH series
2 Pages
-
SB series
1 Pages
-
A series
1 Pages
-
CLG series
6 Pages
-
CLM Series
4 Pages