Catalog excerpts
IMPLANT PROSTHETICS MPS Multi Platform Systems by
Open the catalog to page 1compatible with compatible with BEGO Implant Systems | Semados S-Line Semados RS/RSX-Line | Semados RI-Line compatible with Altatec | Camlog Screw-Line - Root-Line 2 compatible with compatible with compatible with Nobel Biocare | NobelReplace Tapered compatible with Dentsply Implants | ASTRA TECH OsseoSpeed EV compatible with Nobel Biocare | Nobel Active NobelReplace Tapered compatible with compatible with compatible with Nobel Biocare | Brånemark compatible with Straumann | Bone Level compatible with Straumann | Tissue Level compatible with Zimmer Dental | MIS | BioHorizons compatible with...
Open the catalog to page 3B B Series Series The B-Series abutments are compatible with Bredent Medical® SKY® DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments. Type 1 angled over flat Typ 2 abgewinkelt über Nocke Products indicated with ® are registered brand names of respective manufactures
Open the catalog to page 5Laboratory implant • Titanium Implant connection Article No. Abutment screw • Titanium • Torx Article No. Please note: B 60 The correct choice of the abutment screw is stated with the respective abutment in the catalogue. Article No. Please note: B 60 L The correct choice of the laboratory screw is stated with the respective abutment in the catalogue. Titanium base Zirconium abutment 2nd Generation • Titanium grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl. Implant connection Chimney height Gingiva height Article No. Abutment screw Laboratory screw Please note: This is used...
Open the catalog to page 6Titanium base Zirconium abutment 2nd Generation • Titanium grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl. Implant connection Chimney height Gingiva height Article No. Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation. Implant connection Chimney height Gingiva height Article No. Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation. Implant connection Diameter Article No. Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation. Titanium base Bridges/ bars 2nd Generation •...
Open the catalog to page 7MedentiBASE® abutment straight • Titanium Implant connection Gingiva height Article No. MedentiBASE® prosthetic components •B 4840 MedentiBASE® titanium base incl. bridge screw • B 7600 MedentiBASE® bridge screw Torx T6 • Recommended torque: 15 Ncm MedentiBASE® adhesive cap for passive-fit •B 4800 MedentiBASE® adhesive cap Short incl. bridge screw • B 4820 MedentiBASE® adhesive cap Long incl. bridge screw MedentiBASE® scanbody • Titanium grade 5 KV specially coated • incl. bridge screw Article No. Please note: B 4900 The Scanbody is sterilisable and for intra-oral scanning. 11-6 Placement...
Open the catalog to page 8The BS-Series abutments are compatible with BEGO Implant Systems® Semados® S-Line Semados® RS/RSX-Line Semados® RI-Line DETAILANSICHT Genaue Ansicht der Abwinkelung (Indexierung) aller abgewinkelten Abutments. abgewinkelt über Fläche Products indicated with ® are registered brand names of respective manufactures.
Open the catalog to page 11BEGO Implant Systems Semados S - RI - RS - RSX Abutment screw • Titanium • Hex Article No. Please note: BS 60 The correct choice of the abutment screw is stated with the respective abutment in the catalogue. Article No. Please note: BS 60 L The correct choice of the laboratory screw is stated with the respective abutment in the catalogue. Titanium base Zirconium abutment 2nd Generation • Titanium grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl. Implant connection D 4,1 Chimney height 3.5 mm Gingiva height 0,1 mm Article No. BS 1010 Abutment screw BS 60 Laboratory screw BS 60 L...
Open the catalog to page 12BEGO Implant Systems Semados S - RI - RS - RSX Titanium base Bridges/ bars 2nd Generation grade 5 KV • incl. abutment screw • Recommended torque: 30 Ncm Implant connection Chimney height Gingiva height Article No. Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation. TI-Forms®-Abutment for Ceramill • Titanium grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl. Implant connection Diameter Article No. Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation. Scanbody 2nd Generation • Titanium grade 5 KV coated • incl....
Open the catalog to page 13B Serie The C-Series abutments are compatible with Altatec® Camlog Screw-Line – Root-Line 2® BS Serie C Series C Series Serie CX Serie D Serie E Serie EV Serie DETAILANSICHT Genaue Ansicht der Abwinkelung (Indexierung) aller abgewinkelten Abutments. F Serie H Serie I Serie Typ 1 abgewinkelt über Fläche abgewinkelt über Nocke N Serie R Serie S Serie T Serie Products indicated with ® are registered brand names of respective manufactures.
Open the catalog to page 15Altatec Camlog Screw-Line - Root-Line 2 Laboratory implant • Titanium Implant connection Article No. Abutment screw • Titanium • Hex Article No. Please note: C 60 C 61 C 62 The correct choice of the abutment screw is stated with the respective abutment in the catalogue. Article No. Please note: C 61 L C 62 L The correct choice of the laboratory screw is stated with the respective abutment in the catalogue. Titanium base Zirconium abutment 2nd Generation • Titanium grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl. Implant connection D 3,3 D 3,8 D 4,3 Chimney height 3.5 mm 3.5 mm...
Open the catalog to page 16Altatec Camlog Screw-Line - Root-Line 2 Titanium base Zirconium abutment 2nd Generation • Titanium grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl. Implant connection D 3,3 D 3,8 D 4,3 Chimney height 5.5 mm 5.5 mm 5.5 mm Gingiva height 0,3 mm 0,3 mm 0,3 mm Article No. C 1100 C 1110 C 1120 Abutment screw C 61 C 61 C 61 Laboratory screw C 61 L C 61 L C 61 L Please note: This is used with Scanbody 2. generation. Implant connection D 3,3 Chimney height 3.5 mm Gingiva height 0,3 mm Article No. C 1500 Abutment C 60 Please note: This is used with Scanbody 2. generation. Titanium base...
Open the catalog to page 17All Amann Girrbach catalogs and technical brochures
-
General Catalog
111 Pages
-
Guide "Processing Techniques"
36 Pages
-
Clinical Guide III
28 Pages
-
Zolid Bion
8 Pages
-
Ceramill Workflow
60 Pages
-
Ceramill DRS
40 Pages
-
Newsflyer 2023
32 Pages
Archived catalogs
-
AG General Catalogue
111 Pages