Catalog excerpts
Multi-Parameter Patient Monitor xcellent design and performances make the AV-9000C a multi-functional, portable patient monitor, which can be widely used in clinical different hospital departments, like Internal, Operation Theather, ICUs and CCUs. Suitable for adult, pediatric and neonatal patient, it can support additional optional functions such as 12-lead ECG, IBP (single and double), Nellcor SpO2, EtCO2, ICG and multi-gas/O2. The AV-9000C clear user friendly interface allows various display screens adaptable to the environment: standard interface, big font interface and short trend interface, etc. Waveform colors and parameters can be changed according to clinical requirements. The AV-9000C software processing technique, including arrhythmia analysis, pacemaker analysis, oxyCRG, S-T segment analysis, drug dose calculation and more. Nurses and doctors can get the required information for prompt clinic decision-making. Additionally it can save 24 hours' full data, alarm recall and trend graphic after power failure. It can provide nurses with powerful information protection. 12.1" Large-screen Color TFT Display Windows interface mode, easy to operate Optional Multi-language Display Two menu in same screen, operation instruction for each menu selection Display 9 or 12 lead waveform in the same screen S-T segment analysis Arrhythmia analysis Pacemaker analysis oxyCRG interface Drug dose calculation View bed function Full functions: Alarming volume, knob volume, HR volume, voice/light alarm, screen brightness adjustable. • Multi displays selectable including: - Standard interface - Trends graph review interface - Alarm setting interface - Big font interface - oxyCRG interface - Bed to bed view interface - 7 channel / 12 channel display interface • Input patient data • Printed the dug does calculation's result • Selectable printing function. Gridding record paper • Adjustable colors for parameter data and curve • Optional built-in recorder, offer different kinds of recording mode • Recallable and Power Off/Shutdown protected functions: - Trend graph: 120 Hours of storage - Trend tabulation: 120 Hours of storage - NIBP List: 1000 groups of NIBP storage, - Waveform: 30minutes of ECG waveform storage, - Alarming event: storage 500 Alarming event, • Short Trend interface : 2h,4h and 6h selection • Ethernet port built-in for network connection to central monitoring system ©2010, AMBISEA Technology Corp.,Ltd - Rev1.0 01/2010 AMBISEA is a registered trademark of AMBISEA Technology Corp., Ltd
Open the catalog to page 1Safety • ISO 13485:2003 approved, CE marking according to MDD93/42/EEC Operation Environment • • • • Power: AC100-250V, 50/60Hz. Temperature: 0 ~ 40°C Humidity: 15-85% Patient Range: Adult, Pediatric, Neonate Physical Characteristics • • • • • • Inner size: 320 x 70 x 80mm Carton size: 420 x 320 x 400mm Volume: 0.06cbm Gross Weight: 9.5kg Net Weight: 6kg Chargeable Weight: 10 kg Technical Specifications User Interface and Display Module • 12.1" color TFT (diagonal) • Rolling and refreshing waveform display • Resolution: 800x600 • Multi displays selectable, including: - Standard display -...
Open the catalog to page 2Nellcor SpO2 (Optional) • Measurement range: 0~100% • Resolution: 1% • Accuracy: - ±1% (70-100%, MAX-A, MAX-AL, MAX-N, MAX-P, MAX-I and MAX-FAST sensors); - ±2% (70-100%, D-YS, DS-100A, OXI-A/N and OXI-P/I sensors); - 0-69% unspecified • Alarm range: 0~100% • Pulse rate: - Range: 0~254bpm -Resolution: 1bpm -Accuracy: ±3bpm • Alarm range: 0~254bpm NIBP • Measurement method: Automatic vibration • Measurement types: Systolic, Diastolic, Mean • Work mode: Manual / Automatic • Auto measurement time: Adjustable 1~120min • Measurement unit: mmHg / Kpa selectable • Measurement range for...
Open the catalog to page 3Device Configuration • • • • • Display : 12.1'' color TFT (diagonal) Safety standard: IEC60601-1 (GB9706.1) Safety grade: grade-I , CF type, BF type Recorder: Built-in thermal printing Record type : - Consecutive real-time record , - Automatic record , - Parameter alarm record , - Freeze Waveform record , - Review and Saving , - Trend Review Electric specification: AC 220V ±22v, DC 12V, 50Hz ±1Hz Power: <70VA Battery: pluggable and withdrawable rechargeable battery Battery working time: 3 hour Standard configuration: ECG/HR, SpO2, NIBP, Respiration, Temperature, Pulse Standard Accessories...
Open the catalog to page 4All Ambisea Technology catalogs and technical brochures
-
AV-2000 and AV-2010
3 Pages
-
AV-2100
3 Pages
-
AV-500
1 Pages
-
AV-CMxx
2 Pages
-
AV-9060
2 Pages
-
AV-9080
2 Pages
-
AV-9050
2 Pages
-
AV-9000H
4 Pages
-
AV-9000B and D
4 Pages
-
Mobile Handheld Spirometer
1 Pages
-
AV-9120
3 Pages
-
AV-9600
2 Pages
-
AV-9300
2 Pages
-
DIABETES CARE
5 Pages
-
Pocket Fetal Doppler
1 Pages
-
AV 9060
2 Pages