AV-9050
1 /2Pages

AV-9050

AV-9050
1 /2Pages

Catalog excerpts

AV-9050-1

Multi-parameter Patient Monitor Technical Specification Degree of protection against harmful ingress of water JIPV'I Operation Environment Patient Range: Adult, Pediatric. Neonate Physical Characteristics: Performance Specifications Display: 10.4 inch color TFT touch screen (diagonal) Indicator: Power indicator light Battery indicator light Inter face: Parameter cable interface AC Power input socket Network interface Alternate Display Battery: Lithium-ion battery'Rechargeable Plug & play battery, capacity:4000Ma.above 4 hours working time Trend time: 1-120 hours Alarm: User-adjustable High and Low limits audible and visual alarm Networking: Connected to central monitoring system Recorder: Built-in. thermal array Record mode: manual, on alarm, time -defined, etc Internal Modules: Individual Modules ECG module, SpO.- module. N1BP module. Main control module and power supply module. Heart Rate Range Accuracy:S'l% or yjbpm (whichever is greater) Electrode desquamated indicator: Voice & light indication ECG noise level: y 30 uV (P-P value) ECG input loop current: 0.1 Ua Time constant: Anti-jamming : line frequency, electrosurgical interference and defibrillation Arrhythmia Analysis and pacemaker detection ECG cable: standard configuration ECG cable for Adult Standard two ECG cables to support 12 leads ECG analysis Alarm setting: Adjustable from lower to upper and automatic memory Pulse rate: Method: Automatic oscillometric Operation modes: Manual/Automalicf Continuous Measurement unit: mmllg/kPa selectable Measurement types: Systolic, Diastolic. Mean Auto measure time: Adjustable Measurement range: Range of systolic pressure: Adult Mode 40 - 270 mmllg Pediatric Mode 40 - 200 mmllg Neonatal Mode 40 - 135 mini Ig Range of diastolic pressure: Adult Mode 10-210 mmllg Neonatal Mode 10 - 100 mmllg Range of mean pressure: Adult Mode 20 - 230mmllg Neonatal Mode 20-1 lOmmHg Accuracy of blood pressure measurement The mean error shall be less than \'5 mml lg The standard deviation shall be less than 8 mmllg Over-pressure protection: Double safety protection Alarm: Systolic, Diastolic. Mean Mcthod:R-F(RA-LL) impedance method Resolution: yirpm Accuracy: S'lrpm Alarm setting: Adjustable from lower to upper and automatic memory Sampling Rate: 50ml/min yiOml/min Sampling rate accuracy: 15% Start-up time: JI min. once the module starts up, it reaches ISO accuracy Mode: 10 minutes after start-up, the module reaches full accuracy mode Respiration rate accuracy: y2rpm (0-70rpm) (Sampling line length: 7 inches: internal diameter: 0.055 inches; Method: Infrared Absorption Measuring mode: Mainstream Resolution: 0.1 mmllg 0 to69 mmllg 3905 Two Exchange Square, Suite 7698,8 Connaught Place, Central,Hongkong www.ambisea.com [email protected] Multi-parameter Patient

 Open the catalog to page 1
AV-9050-2

■ Fixed handle, easy ■ 4000mAh Li-ion batteries, above 4 hours ■ Auto dust shield to prevent ■ Handwriting pen to move. working time. from foreign matters. with slot Interfaces: Mounting solutions: vertical hanging, wall mounting, rolling stand. Complying with CE standards, integrated modular design and aluminum alloy structure gives better guarantee to product safety & stability. International pop design, splendid appearance, best craftswork. IPX1 waterproof design, good performace in various ■ I-Klok™ Intelligent alarm management, automatic-identification of alarm level. Self-adjust proper...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.