Multi-parameter Patient Monitor Technical Specification Degree of protection against harmful ingress of water JIPV'I Operation Environment Patient Range: Adult, Pediatric. Neonate Physical Characteristics: Performance Specifications Display: 10.4 inch color TFT touch screen (diagonal) Indicator: Power indicator light Battery indicator light Inter face: Parameter cable interface AC Power input socket Network interface Alternate Display Battery: Lithium-ion battery'Rechargeable Plug & play battery, capacity:4000Ma.above 4 hours working time Trend time: 1-120 hours Alarm: User-adjustable High and Low limits audible and visual alarm Networking: Connected to central monitoring system Recorder: Built-in. thermal array Record mode: manual, on alarm, time -defined, etc Internal Modules: Individual Modules ECG module, SpO.- module. N1BP module. Main control module and power supply module. Heart Rate Range Accuracy:S'l% or yjbpm (whichever is greater) Electrode desquamated indicator: Voice & light indication ECG noise level: y 30 uV (P-P value) ECG input loop current: 0.1 Ua Time constant: Anti-jamming : line frequency, electrosurgical interference and defibrillation Arrhythmia Analysis and pacemaker detection ECG cable: standard configuration ECG cable for Adult Standard two ECG cables to support 12 leads ECG analysis Alarm setting: Adjustable from lower to upper and automatic memory Pulse rate: Method: Automatic oscillometric Operation modes: Manual/Automalicf Continuous Measurement unit: mmllg/kPa selectable Measurement types: Systolic, Diastolic. Mean Auto measure time: Adjustable Measurement range: Range of systolic pressure: Adult Mode 40 - 270 mmllg Pediatric Mode 40 - 200 mmllg Neonatal Mode 40 - 135 mini Ig Range of diastolic pressure: Adult Mode 10-210 mmllg Neonatal Mode 10 - 100 mmllg Range of mean pressure: Adult Mode 20 - 230mmllg Neonatal Mode 20-1 lOmmHg Accuracy of blood pressure measurement The mean error shall be less than \'5 mml lg The standard deviation shall be less than 8 mmllg Over-pressure protection: Double safety protection Alarm: Systolic, Diastolic. Mean Mcthod:R-F(RA-LL) impedance method Resolution: yirpm Accuracy: S'lrpm Alarm setting: Adjustable from lower to upper and automatic memory Sampling Rate: 50ml/min yiOml/min Sampling rate accuracy: 15% Start-up time: JI min. once the module starts up, it reaches ISO accuracy Mode: 10 minutes after start-up, the module reaches full accuracy mode Respiration rate accuracy: y2rpm (0-70rpm) (Sampling line length: 7 inches: internal diameter: 0.055 inches; Method: Infrared Absorption Measuring mode: Mainstream Resolution: 0.1 mmllg 0 to69 mmllg 3905 Two Exchange Square, Suite 7698,8 Connaught Place, Central,Hongkong www.ambisea.com info@ambisea.com Multi-parameter Patient
Open the catalog to page 1■ Fixed handle, easy ■ 4000mAh Li-ion batteries, above 4 hours ■ Auto dust shield to prevent ■ Handwriting pen to move. working time. from foreign matters. with slot Interfaces: Mounting solutions: vertical hanging, wall mounting, rolling stand. Complying with CE standards, integrated modular design and aluminum alloy structure gives better guarantee to product safety & stability. International pop design, splendid appearance, best craftswork. IPX1 waterproof design, good performace in various ■ I-Klok™ Intelligent alarm management, automatic-identification of alarm level. Self-adjust...
Open the catalog to page 2All Ambisea Technology catalogs and technical brochures
-
AV-2000 and AV-2010
3 Pages
-
AV-2100
3 Pages
-
AV-500
1 Pages
-
AV-CMxx
2 Pages
-
AV-9060
2 Pages
-
AV-9080
2 Pages
-
AV-9000H
4 Pages
-
AV-9000C
4 Pages
-
AV-9000B and D
4 Pages
-
Mobile Handheld Spirometer
1 Pages
-
AV-9120
3 Pages
-
AV-9600
2 Pages
-
AV-9300
2 Pages
-
DIABETES CARE
5 Pages
-
Pocket Fetal Doppler
1 Pages
-
AV 9060
2 Pages