AV 9060 - 1

AV 9060 Safety ISO 13485:2003 approved Dimension and Weight DimensionЈ249mmЎ223mmЎ107mm Weight: 3.5kg Operation Environment Power: AC100-250V, 50/60Hz. Temperature: 0-40Ў Humidity: 15-85% Respiration Method: Thoracic impedance RR measurement range: 7-150rpm Resolution: Ў1 rpm Accuracy: Ў1rpm Nellcor SpO 2 Technology: Nellcor OxiMax SpO2 Display: Spo2 digital, Pulse columnar graphics, volume waveform, Pulse rate Patient Range: Neonate Performance Specifications Display: 8.4inch color TFT touch screen (diagonal) Resolution: 800Ў600 Trace: 9 waveforms Sweep Speed:12.5mm/s, 25mm/s, 50mm/s Indicator: Power indicator light Battery indicator light Alarm indicator light QRS beep and alarm sound Inter face: Parameter cable inter face AC Power input socket Network inter face SD card socket Battery: Lithium-ion battery /Rechargeable 4hours for continuous working Trend time: 1~120 hours Alarm: User-adjustable High and Low limits alarm events recallable audible and visual alarm Networking: Connected to central monitoring system Recorder: Built-in, thermal array, 2 traces, paper width:50mm Record mode: manual, on alarm, time -defined Print speed: 12.5 mm/s, 25mm/s, 50mm/s Pulse Rate Accuracy: Ў1bpm Pulse Rate range: Alarm: 20-300 bpm Auto SatSeconds TM Technology SPO2 sensor : Nellcor Neonate Sensor, binding shape, and disposable strap , Pediatric click sensor Alarm setting: Adjustable from lower to upper and automatic memory Alarm type: Systolic pressure, Diastolic pressure, Mean pressure Accuracy: Ў5mmHg NIBP pressure range: 0~300 mmHg PR from NIBP: Measurement 40-240bpm Over-pressure protection: Neonate: 150mmHg Pediatric: 240mmHg IBP Measurement Range: -30mmHgЎ300mmHg Channel: 2 channels Pressure names: ARP,PA, CVP, RAP, LAP, ICP, P1, P2 Accuracy: Ў1% or Ў1bpm, whichever is greater Calibration Mode: Zero Calibration Temperature Measurement range: 0-50Ў Resolution: 0.1Ў Accuracy: Ў0.1Ў Measurement unit: Ў / F selectable o NIBP Measurement method: Automatic vibration, Adap-DSP NIBP cuff: PHILIPS cuff, four size Measurement types: Systolic, Diastolic, Mean Work mode: Manual / Automatic Auto measurement time: Adjustable 1min-480min Measurement unit: Measurement range: Pediatric Mode: Systolic pressure: Diastolic pressure: Mean pressure: Neonatal Mode: Systolic pressure: Diastolic pressure: Mean pressure: ECG Technology: COMEN ExNeo TM Lead selection: 3-lead(Standard) EtCO 2 - Sidestream/Mainstream (option) Method: Infrared Absorption Technique Sample Rate: 50mL/min. Ў10 mL/min (sidestream) CO 2 Measurement Range: 0 to 150 mmHg 0.1 mmHg 0 to 69 mmHg CO 2 Resolution: 0.25 mmHg 70- 150 mmHg 0-40 mmHg Ў2 mmHg CO 2 Accuracy: 41-70 mmHg Ў5%of reading 71-100mmHg Ў8% of reading 101-150mmHg Ў 10% of reading AwRR: Ў 1 rpm Response time: <3 seconds, includes transport time, risetime Calculation Method: BTPS (Body Temperature Pressure Saturated) Sample Gas Flowrate: 50ml/mi Standard Configuration Ў Nellcor OxiMax SpO2 Ў NIBP Ў Respiration Ў Temperature Ў Pulse Ў Backside Hook (Fix to incubator) Ў ECG/HR Optional Configuration Ў IBP Ў Dual Temperature Ў Thermal Recorder Ў Central Monitor Station for Neonatal and Pediatric Patient AMBISEA Technology Corp., Ltd 3905 Two Exchange Square, Suite 7698,8 Connaught Place, Central,Hongkong Phone : +852 3596-6988, Fax : +852 2891-1618 www.ambisea.com info@ambisea.com

Open the catalog to page 1
AV 9060 - 2

Neonatal Monitor SatSeconds=Desaturation PointsXSeconds SatSeconds Alarm Management violations vs.Alarms Low SpOz alarm limit 90%,SatSeconds set to 100 SatSeconds™ intelligent alarm management technology to reduce the wrong alarm, doctor can get the latest 1 SpOais 2 points below 90% for 10 seconds -20 SatSeconds —► No Alarm 2 SpO?is 4 points below 90% for 5 seconds =20 SatSeconds —> No Alarm 3 SpOiis 10 points below 90% for 10 seconds =100 SatSeconds—► Alarm /^\ 4 SpOiis 3 points below 90% for 34 seconds =102 SatSeconds—»Alarm a CE qualified special neonatal wrapping Sp02 sensor,...

Open the catalog to page 2

All Ambisea Technology catalogs and technical brochures

  1. AV-2100

    3 Pages

  2. AV-500

    1 Pages

  3. AV-CMxx

    2 Pages

  4. AV-9060

    2 Pages

  5. AV-9080

    2 Pages

  6. AV-9050

    2 Pages

  7. AV-9000H

    4 Pages

  8. AV-9000C

    4 Pages

  9. AV-9120

    3 Pages

  10. AV-9600

    2 Pages

  11. AV-9300

    2 Pages