AV-9060

AV-9060

AV-9060

Product catalog summary
Safety and Compliance: The device is ISO 13485:2003 approved, ensuring it meets international standards for medical devices.
Dimensions and Weight: The monitor measures 249mm x 223mm x 107mm and weighs 3.5kg.
Power and Environment: Operates on AC100-250V, 50/60Hz. Suitable for temperatures between 0-40°C and humidity levels of 15-85%.
Display and Interface: Features an 8.4-inch color TFT touch screen with a resolution of 800x600. Includes various interfaces such as parameter cable, AC power input, network, and SD card socket.
Battery and Operation: Equipped with a rechargeable lithium-ion battery allowing 4 hours of continuous operation. Trend time ranges from 1 to 120 hours.
Alarms and Indicators: User-adjustable high and low limits with audible and visual alarms. Indicators for power, battery, and alarms are present.
Networking and Recording: Can connect to a central monitoring system. Built-in thermal array recorder with manual, alarm, and time-defined modes.
ECG and Performance Specifications: Supports 3-lead ECG with thoracic impedance method. Measures RR range from 7-150rpm with a resolution of ±1 rpm.
SpO2 and Pulse Rate: Utilizes Nellcor OxiMax technology. SpO2 measurement range is 0-100% with a resolution of 1% and accuracy of ±1% (90-100%) and ±2% (70-90%). Pulse rate range is 20-300 bpm with an accuracy of ±1 bpm.
NIBP Measurement: Uses PHILIPS cuff with adjustable auto measurement time. Systolic, diastolic, and mean pressures are measured with accuracy of ±5mmHg.
Temperature and CO2 Measurement: Temperature measurement range is 0-50°C with a resolution of 0.1°C. CO2 measurement range is 0 to 150 mmHg with varying accuracy based on the range.
Additional Features: Includes options for dual temperature, thermal recorder, and special accessories for neonatal and pediatric patients.
Contact Information: AMBISEA Technology Corp., Ltd, located in Hong Kong. Phone: +852 3596-6988, Fax: +852 2891-1618, Website: www.ambisea.com, Email: [email protected].
See more

Catalog excerpts

AV-9060-1

AV 9060 Safety ISO 13485:2003 approved Dimension and Weight DimensionЈ249mmЎ223mmЎ107mm Weight: 3.5kg Operation Environment Power: AC100-250V, 50/60Hz. Temperature: 0-40Ў Humidity: 15-85% Respiration Method: Thoracic impedance RR measurement range: 7-150rpm Resolution: Ў1 rpm Accuracy: Ў1rpm Nellcor SpO 2 Technology: Nellcor OxiMax SpO2 Display: Spo2 digital, Pulse columnar graphics, volume waveform, Pulse rate Patient Range: Neonate Performance Specifications Display: 8.4inch color TFT touch screen (diagonal) Resolution: 800Ў600 Trace: 9 waveforms Sweep Speed:12.5mm/s, 25mm/s, 50mm/s Indicator: Power indicator light Battery indicator light Alarm indicator light QRS beep and alarm sound Inter face: Parameter cable inter face AC Power input socket Network inter face SD card socket Battery: Lithium-ion battery /Rechargeable 4hours for continuous working Trend time: 1~120 hours Alarm: User-adjustable High and Low limits alarm events recallable audible and visual alarm Networking: Connected to central monitoring system Recorder: Built-in, thermal array, 2 traces, paper width:50mm Record mode: manual, on alarm, time -defined Print speed: 12.5 mm/s, 25mm/s, 50mm/s Pulse Rate Accuracy: Ў1bpm Pulse Rate range: Alarm: 20-300 bpm Auto SatSeconds TM Technology SPO2 sensor : Nellcor Neonate Sensor, binding shape, and disposable strap , Pediatric click sensor Alarm setting: Adjustable from lower to upper and automatic memory Alarm type: Systolic pressure, Diastolic pressure, Mean pressure Accuracy: Ў5mmHg NIBP pressure range: 0~300 mmHg PR from NIBP: Measurement 40-240bpm Over-pressure protection: Neonate: 150mmHg Pediatric: 240mmHg IBP Measurement Range: -30mmHgЎ300mmHg Channel: 2 channels Pressure names: ARP,PA, CVP, RAP, LAP, ICP, P1, P2 Accuracy: Ў1% or Ў1bpm, whichever is greater Calibration Mode: Zero Calibration Temperature Measurement range: 0-50Ў Resolution: 0.1Ў Accuracy: Ў0.1Ў Measurement unit: Ў / F selectable o NIBP Measurement method: Automatic vibration, Adap-DSP NIBP cuff: PHILIPS cuff, four size Measurement types: Systolic, Diastolic, Mean Work mode: Manual / Automatic Auto measurement time: Adjustable 1min-480min Measurement unit: Measurement range: Pediatric Mode: Systolic pressure: Diastolic pressure: Mean pressure: Neonatal Mode: Systolic pressure: Diastolic pressure: Mean pressure: ECG Technology: COMEN ExNeo TM Lead selection: 3-lead(Standard) EtCO 2 - Sidestream/Mainstream (option) Method: Infrared Absorption Technique Sample Rate: 50mL/min. Ў10 mL/min (sidestream) CO 2 Measurement Range: 0 to 150 mmHg 0.1 mmHg 0 to 69 mmHg CO 2 Resolution: 0.25 mmHg 70- 150 mmHg 0-40 mmHg Ў2 mmHg CO 2 Accuracy: 41-70 mmHg Ў5%of reading 71-100mmHg Ў8% of reading 101-150mmHg Ў 10% of reading AwRR: Ў 1 rpm Response time: <3 seconds, includes transport time, risetime Calculation Method: BTPS (Body Temperature Pressure Saturated) Sample Gas Flowrate: 50ml/mi Standard Configuration Ў Nellcor OxiMax SpO2 Ў NIBP Ў Respiration Ў Temperature Ў Pulse Ў Backside Hook (Fix to incubator) Ў ECG/HR Optional Configuration Ў IBP Ў Dual Temperature Ў Thermal Recorder Ў Central Monitor Station for Neonatal and Pediatric Patient AMBISEA Technology Corp., Ltd 3905 Two Exchange Square, Suite 7698,8 Connaught Place, Central,Hongkong Phone : +852 3596-6988, Fax : +852 2891-1618 www.ambisea.com [email protected]

 Open the catalog to page 1
AV-9060-2

Neonatal Monitor SatSeconds=Desaturation PointsXSeconds SatSeconds Alarm Management violations vs.Alarms Low SpOz alarm limit 90%,SatSeconds set to 100 SatSeconds™ intelligent alarm management technology to reduce the wrong alarm, doctor can get the latest 1 SpOais 2 points below 90% for 10 seconds -20 SatSeconds —► No Alarm 2 SpO?is 4 points below 90% for 5 seconds =20 SatSeconds —> No Alarm 3 SpOiis 10 points below 90% for 10 seconds =100 SatSeconds—► Alarm /^\ 4 SpOiis 3 points below 90% for 34 seconds =102 SatSeconds—»Alarm a CE qualified special neonatal wrapping Sp02 sensor, anti-avulsion,...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.