AV-9080 - 1

intensive Care Unit Monitor Technical Specification against harmful ingress of water JlPy I Operation Environment Patient Range: Adult. Pediatric. Neonate Physical Characteristics: Performance Specifications Display: 12.1 inch color TFT touch screen (diagonal) Rolling and refreshing waveform display Multi displays selectable, including: Standard display Freeze display Large -font Display Trend coexist display Alarm limit display OxyCRG dynamic view display Bed-to-bed view display Multi-lead and ECG simultaneous display Indicator: Power indicator light Battery indicator light Inter face: Parameter cable inter face AC Power input socket Network inter face Alternate Display Battery: Lithium-ion battery /Rechargeable Plug & play battery, capacity:4000mA Maximum 12 hours for charging; 4 hours for continuous working Trend time: 1-120 hours Alarm: User-adjustable Nigh and Low limits audible and visual alarm Networking: Connected to central monitoring system Recorder: Built-in, thermal array Record mode: manual, on alarm, time -defined, etc Print speed: 12.5 mm/s, 25mm/s, SOinm/s Internal Modules: Individual Modules ECG module. SpO: module, NIBP module. Main control module and power supply module. Heart Rate Range Accuracy: v 1% or yjbpm (whichever is greater) Electrode desquamated indicator: Voice & light indication ECG noise level: = 30 uV (P-P value) ECG input loop current: 0.1 Ua Time constant: Anti-jamming: line frequency, electrosurgical interference and defibrillation Arrhythmia Analysis and pacemaker detection ECG cable: standard configuration ECG cable for Adult Standard two ECG cables to support Alarm setting: Adjustable from lower to upper Waveform: standard 12-ECG waveforms Nellcor SpO>-Standard Display: SpO: digital. Pulse columnar graphics, volume waveform. Pulse rate y2% (90-100%, MAX-A, MAX-AL, MAX-N. MAX-P, MAX-land MAX-FAST sensors); Pulse rate: Resolution: Ibpm Exclusive SatSecondsn'alarm management system, much lower false alarms, much less word for users AcuTcc"' NIBP Measurement method: Automatic vibration Measurement types: Systolic, Diastolic. Mean Work mode: ManualAutomatic/Continuous Auto measurement time: Adjustable lmin-480min Measurement unit: inmllg / Kpa selectable Neonatal Mode: Systolic pressure25-l35mmllg Diastolic pressure 12-1 lOmmllg Alarm type Systolic pressure. Diastolic pressure. Mean pressure NIBP pressure range: 0-300 mmllg PR from NIBP: Measurement 40-240bpm Over-pressure protection: Hardware and software both over pressure protection Higher than the above pressure, the safety valve deflate automatically. NIBP cuff: Standard - Adult NIBPcuff; Optional - Pediatric NIBP cuff. Neonatal NIBPcuff Alarm setting: Adjustable from lower to upper and automatic memory Measurement Mode: Pressure Transducer Measurement Types: Systolic, Diastolic, Mean IBP Accuracy: 0y lOOmmHg SMmmllg Calibration Mode: Zero Calibration Dual TEMP Channel: Tl, T2, TD (Temperature Difference) Accuracy: 0. iy(exclusive of error of sensor) Measurement unit: C / F selectable TEMP sensor: standard configuration- skin TEMP sensor. Alarm setting: Adjustable from lower to upper Method:R-F(RA-LL) impedance method Accuracy: lrpm Alarm setting: Adjustable from lower to upper ARR analysis, RESP Apnea Alarm: 10s-40s Sampling Rate: 50ml/min. yiOml/min Sampling rate accuracy: 15% Starl-up time: Jl min, once the module starts up, Mode: 10 minutes after starl-up, the module reaches full accuracy mode Respiration rate accuracy: y2rpm (0-7()rpm) (Sampling line length: 7 inches; internal diameter: 0.055 inches; sampling gas flow rate: 150ml/min) Method: Infrared Absorption Measuring mode: Mainstream 3905 Two Exchange Square, Suite 7698,8 Connaught Place, Central,Hongkong www.ambisea.com info@ambisea.com Care Unit

Open the catalog to page 1
AV-9080 - 2

Critical time Seize every second for saving life C80 uses CardioTec"'' ECG technology, world leading OxiMax" technology, high precision AcuTec'" hypertension monitoring technology as standard configuration. C80 incorporates world's best medical technology for SpO,, ICG , EtC02, Anesthesia Gas Monitoring from the world's best OEM technology providers like NELLCOR, RESPIRONICS, ARTEMA & BIOZ. Precisely, C80 provides medical professionals with powerful monitoring options and functionality to match the demands of a wide range of care , in any hospital environment. CardioTec™ technology 12-lead...

Open the catalog to page 2

All Ambisea Technology catalogs and technical brochures

  1. AV-2100

    3 Pages

  2. AV-500

    1 Pages

  3. AV-CMxx

    2 Pages

  4. AV-9060

    2 Pages

  5. AV-9050

    2 Pages

  6. AV-9000H

    4 Pages

  7. AV-9000C

    4 Pages

  8. AV-9120

    3 Pages

  9. AV-9600

    2 Pages

  10. AV-9300

    2 Pages

  11. AV 9060

    2 Pages