Catalog excerpts
MultiParameter Patient Monitor HospitalGrade Patient Monitor for Neonatal applications Features • • • • • 8.4” touch screen Color TFT Display With stable working system, special model for transporting patient Windows interface mode, easy to operate Multilanguage support Display two menu in same screen, operation instruction for each menu selection • Max display 6 waveform in the same screen • ST segment analysis • Arrhythmia analysis • Pacemaker detection and antidefibrillation • OxyCRG interface • Optional Sidestream or Mainstream EtCO2 module Drug dose calculation Full functions: alarm volume knob volume HR volume audible/visual alarm screen brightness adjustable Multi displays selectable including: Standard interface Trends graph review interface Alarm setting interface Big font interface OxyCRG interface bed to bed view interface Selectable printing function both grid record paper and nongrid paper supported Adjustable colors for parameter data and curve Optional builtin recorder, support various of recording mode Events recorded that can be recalled and printed (including power off protection): Trend graph: 96 hours of trend graph storage Trend tabulation: 96 hours of Trend Tabulation storage NIBP List: 400 groups of NIBP storage Waveform: last 4 minutes of ECG waveform storage Alarming event: 500 alarms event storage Short Trend interface: 2 hours Central Monitoring connectivity: IP net socket, wire and wireless network available maximum 128 units of patient monitors can be connected to central monitoring station ©2010, AMBISEA Technology Corp.,Ltd Rev2.0 05/2012 AMBISEA is a registered trademark of AMBISEA Technology Corp., Ltd
Open the catalog to page 1Operation Environment • • • • • Power: AC100250V, 50/60Hz Temperature: 0 ~ 40°C Humidity: 15 ~ 85% Patient Range: Adult, Pediatric, Neonate Net weight: 2.5kg Display: 8.4” color TFT touch screen (diagonal) Rolling and refreshing waveform display Resolution: 800x600 Multi displays selectable, including: Standard display Freeze display Large font Display Trend coexist display Alarm limit display OxyCRG dynamic view display Bedtobed view display Multilead and ECG simultaneous display Trace: 6 waveforms Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s Indicator: Power indicator...
Open the catalog to page 2• Measurement range: 0 ~ 100% • Resolution: 1% • Accuracy: ±2% (70100%, MAXA, MAXAL, MAXN, MAXP, MAXI and MAXFAST sensors) ±3% (70100%, DYS, DS100A, OXIA/N and OXIP/I sensors) 069% unspecified • Alarm range: 0 ~ 100% • Pulse rate: Range: 0 ~ 254bpm Resolution: 1bpm Accuracy: ±3bpm Alarm range: 0 ~ 254bpm • Measurement method: Automatic vibration • Measurement types: Systolic Diastolic Mean • Work mode: Manual / Automatic • Auto measurement time: Adjustable 1480min • Measurement unit: mmHg / Kpa selectable • Measurement range: Adult: . Systolic pressure 40...
Open the catalog to page 3Mainstream CO2 • Method: Infrared Absorption • Measuring mode: Mainstream • Measurement range: 0 ~ 150mm Hg, 0 to 79%, 0 to 20kPa (at 760mmHg) • Resolution: 0.1mmHg 0 to 69mmHg 0.25mmHg 70 to 150mmHg • Accuracy: ±2 mm Hg (0 – 40 mm Hg) ±5% of reading (41 – 70 mm Hg) ±8% of reading (71 –100 mm Hg) ±10% of reading (101 –150 mm Hg) • Alarm range: Same as Measurement range Other parameter • • • • • • • • Safety standard: IEC606011 (GB9706.1) Safety grade: gradeI, CF type, BF type Recorder: Builtin thermal printing Record type : Consecutive realtime record, Automatic record,...
Open the catalog to page 4All Ambisea Technology catalogs and technical brochures
-
AV-2000 and AV-2010
3 Pages
-
AV-2100
3 Pages
-
AV-500
1 Pages
-
AV-CMxx
2 Pages
-
AV-9060
2 Pages
-
AV-9080
2 Pages
-
AV-9050
2 Pages
-
AV-9000H
4 Pages
-
AV-9000C
4 Pages
-
AV-9000B and D
4 Pages
-
Mobile Handheld Spirometer
1 Pages
-
AV-9120
3 Pages
-
AV-9600
2 Pages
-
AV-9300
2 Pages
-
DIABETES CARE
5 Pages
-
Pocket Fetal Doppler
1 Pages
-
AV 9060
2 Pages