Group: Ambulances Manufacturer

Catalog excerpts

PRODUCT MANUAL USER PROJECT NAME: FIELD HOSPITAL
Open the catalog to page 1
Manual User SYSTEM PREFACE In times of crisis, be it natural disasters, pandemics, or conflicts, the need for rapid and effective medical response is paramount. Traditional healthcare infrastructures often face overwhelming challenges during such events, struggling to accommodate the surge in patient numbers and provide adequate care. In response to these challenges, the concept of field hospitals has emerged as a crucial component of emergency medical preparedness and response. Field hospitals are temporary medical facilities established to provide emergency healthcare services in areas...
Open the catalog to page 2
Manual User GENERAL INFORMATION OF THE SYSTEM 1. Electrical System: The electrical system of the field hospital comprises wiring, fuses, outlets, switches, and circuit breakers to facilitate the operation of medical equipment, lighting, cooling systems. It includes distribution panels to manage power distribution within the facility and ensure balanced loads. Emergency backup power sources, such as batteries, are integrated into the electrical system to provide uninterrupted power supply during outages or when off-grid. 2. Energy Sources: Generators: Field hospitals are equipped with a...
Open the catalog to page 3
Manual User STEPS FOR SYSTEM FUNCTIONS 1. FIRST STEPS ELECTRICAL SYSTEM ACTIVATION: Start the generator and plug the cable connected to the generator to the field hospital container’s external plug. The energy coming from the generator can be used at the same time and be stored by the batteries too. External Plug If the sun is sunny then, you can just turn on the solar panel switch(Red colour) located on the electrical board and let all the electrical system using fully the energy coming from the sun, the energy coming from the sun will be stored by the 4*200A batteries and can be used...
Open the catalog to page 4
Manual User The solar panels are to be cleaned every one week to make sure there’s no dust on the panels so that the solar panel produce efficiently the energy without any problem. The panels are assembled on the frame structure flexible for installation and maintenance. It can rotate 180 degre for maintenance purposes. Fuse located under the inverter is to be turn on before using the electrical system and is to be turn off when electrical system is not to be used in other to save the energy. Once turning on the fuse please wait for 30 second for launching the system. 4*200A Batteries These...
Open the catalog to page 5
Manual User Engine Switch Starts and stops the engine. For electrical starter, hold it at START position. Mechanism of Rope Operation To start the engine, by clearing its gap, slowly turn the starter holder until it stucks and then pull it quickly. IMPORTANT Do not allow the starter to hit the engine while returning. To protect the starter from harm, return it slowly to it’s initial position. The fuel valve is located between the fuel tank and carburetor. When the valve lever is at ON position, the fuel can flow from the fuel tank to the carburetor. Be sure to return the lever to OFF...
Open the catalog to page 6
Manual User An earth rod (or electrode) is a typically a conductive rod of steel or copper driven into the ground and connected to an EV chargepoint. This connection helps to protect the user from potentially lethal electrocution should the electricity distribution system supplying the property develop a fault. How to use it: Simply place the pointed end of the ground rod into the hole you dug. Then, stand over the rod and use a hammer or mallet to gradually drive the rod vertically into the ground. Indoor Unit Air Conditioning Outdoor Unit Air Conditioning
Open the catalog to page 7
Manual User SOCKETS AND LIGHT SWITCHES These sockets shown below here are in the patient compartment, it’s used for charging medical devices or any chargeable device and light switches are used to turn on and of the lights. Light’s Switch located from the entrance is used to turn on the inner light and the outdoor’s light.
Open the catalog to page 8
Manual User 2- SECOND STEPS WATER SYSTEM: Make sure to fill the clean water tank first, and check from the tank’s tube if the water is fully filled or not. After making sure that the tank is filled and the elcetrical syste is activated then plug the Hydrofort pump’s plug to the socket beside it, the hydrofort will start working and pressurised the water from the tank then we can start using the sink located in the patient compartment. Hydrofort Pump: this hydrofort pump is employed to pressurize and distribute water from the storage tank to various points of use within the facility. It...
Open the catalog to page 9
Manual User Water Sink The water that comes out from the tap originates from the main water supply that runs through pipes in the tank. The water that comes out from the tap visibly flows into the sink and goes down the drain which leads to the sink trap and goes to the waste water tank. Door’s step, it can be locked or dissambled during transportation from one place to another
Open the catalog to page 10All AmbulanceMed catalogs and technical brochures
-
Toyota Hiace Ambulance Catalog
63 Pages
-
20FT W TOYOTA HINO 300
9 Pages
-
Land Cruiser Ambulance Catalog
124 Pages
-
FORD TRANSIT BLOOD TEST UNIT
53 Pages
-
Field Hospital
32 Pages
-
Ambulancemed Brochure
8 Pages
-
GMC AMBULANCE Presentation
8 Pages
-
Isuzu Fire Truck
6 Pages
-
Iveco Fire Truck
9 Pages
-
Mercedes Fire Truck
6 Pages
Archived catalogs
-
PLATFORM TRUCK
18 Pages
-
B7 ARMOR LAND CRUISER 78
6 Pages
-
B6 ARMOR LAND CRUISER 78
6 Pages
-
RESCUE Life
14 Pages