1. Catalogs
  2. AMEDTEC Medizintechnik
  3. CARDIOPART 12 USB / USB-P

CARDIOPART 12 USB / USB-P

CARDIOPART 12 USB / USB-P

CARDIOPART 12 USB / USB-P

Product catalog summary
Overview
The document provides technical specifications and features of the CardioPart 12 USB/USB-P, a 12-lead PC ECG device designed for healthcare professionals. It emphasizes flexibility, ease of handling, and integration into paperless workflows.

Key Features
  • Highly flexible and easy to handle.
  • Reliable pacemaker detection.
  • Seamless integration into paperless workflows.

Technical Specifications
  • Patient Safety: Requires a patient cable with a protective resistor of 10 kOhm for defibrillator discharge protection.
  • Dynamic Range: +/- 316 mV DC.
  • Sample Rate: 8000 Hz for each of the 10 electrode channels.
  • Resolution: 1 μV/LSB.
  • Frequency Range: 0 - 150 Hz.
  • Input Impedance: > 50 MOhm.
  • Input Protection: Against defibrillator shock and HF from surgery devices.
  • PC Interface: USB 2.0 with a 5-meter cable.
  • Power Supply: Via USB port of the PC.
  • Size and Weight: 95 mm x 64 mm x 28 mm, 90 g.
  • Standards: Complies with DIN EN 60601-1, DIN EN 60601-1-2, DIN EN 60601-2-25, ANSI/AAMI EC 11.

Functionality
  • Supports resting ECG, stress test ECG, and spirometry.
  • Compatible with hospital information systems and practice computer systems.
  • Offers automatic measurement, interpretation, and rhythm ECG options.
  • Includes online arrhythmia detection and control of ergometers and blood pressure meters.

Communication and Compatibility
  • Supports KIS, PACS, and BDT/GDT communication.
  • Optional HL7/DICOM support.

Certification
  • Certified under DIN EN ISO 134850494.

Contact Information
AMEDTEC Medizintechnik Aue GmbH, Schneeberger Straße 5, 08280 Aue, Germany. Phone: +49 (0)3771 59 82 70, Email: [email protected], Website: www.amedtec.de
See more

Catalog excerpts

CARDIOPART 12 USB / USB-P-1

HEALTH IS THE HEART OF OUR BUSINESS. Highly flexible Easy handling Excellent, proven technology Reliable pacemaker detection Fits perfectly into a paperless workflow MANAGE COMPLEX DATA EASILY

 Open the catalog to page 1
CARDIOPART 12 USB / USB-P-2

TECHNICAL DATA Dynamic range Sample rate 8000 Hz [125 μs] for each of the 10 electrode channels Frequency range Pacemaker detection digital monitoring of all electrodes Input impedance Electrodes check frequency analysis and impedance measurement Input protection against defibrillator shock1) and HF from surgery devices Patient cable connection 15-Pin D-Sub for 10-lead patient cable Applied part Power supply R wave trigger output 1) Patient cable or suction electrode system must feature a protective resistor of 10 kOhm in each of the cables. The use of such patient cable provides for protection...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.