Product Overview
The ITRIXII is a Rapamycin Eluting Coronary Stent Implantation System developed by The Stent Company International. It features a stainless steel, bioactive carbonized stent platform with a semi-compliant rapid exchange catheter. The system is designed for use with a 0.014” guidewire and a 5 F guiding catheter.
Technical Specifications
The stent system offers a range of diameters from 2.00 mm to 4.00 mm, with nominal pressures of 9 bar and rated burst pressures of 18 bar for smaller diameters and 16 bar for the largest. The stent-strut thickness varies slightly between small (110 microns) and large (115 microns) sizes, with a carbon ion implantation depth of 50 nm.
Order Information
The system is available in various stent and balloon lengths, accommodating different vessel sizes and clinical needs.
Benefits and Outcomes
The ITRIXII system boasts a 0.0% thrombosis rate over a 24-month period, with clinical data supporting its efficacy. The biodegradable polymer coating degrades within six weeks in vivo, releasing Rapamycin at a controlled rate to prevent thrombotic and re-stenotic events.
Coating and Technology
The biodegradable polymer consists of Poly-lactic-co-glycolic acid (PLGA), which degrades into carbon dioxide and water. The Rapasorb™ technology ensures simultaneous polymer degradation and drug release, tailored to immune responses post-implantation. Inert Carbon Technology involves high-speed bombardment of carbon ions onto the stent surface, enhancing its properties.
Compliance Table
The compliance table provides detailed information on balloon diameters at various pressures, ensuring precise deployment and performance of the stent system.
See more

Catalog excerpts

ITRIXII-1

INTERVENTIONAL CARDIOLOGY II Rapamycin Eluting Coronary Stent Implantation System with Fast Absorbable Bio-Polymer TECHNICAL SPECIFICATIONS » International The Stent Company ITRIX11 Rapamycin Eluting Coronary Stent Implantation System with Fast Absorbable Bio-Polymer ORDER INFORMATION Stent Length (mm) IjlBalloon Length (mm) amg » International The Stent Company amg International GmbH BoschstraBe 16 D-21423 Winsen Germany Status June 2017 PS ITX_05 Made in Germany

 Open the catalog to page 1
ITRIXII-2

Rapamycin Eluting Coronary Stent Implantation System Release Kinetics of Rapamycin Eluting Coronary Stent Implantation System (Long term release per square mm stent surface) with Fast Absorbable Bio-Polymer The ITRIXII Rapamycin Eluting Coronary Stent Implantation System is the first carbonized stent (Inert Carbon Technology) with a completely biodegradable polymer coating which contains Rapamycin (Rapasorb™) as a highly effective drug for preventing thrombotic and re-stenotic events. ITRIXII Subject: Drug concentration BENEFITS No stent thrombosis during the entire 2-year follow-up period (clinical...

 Open the catalog to page 2

All Amg International catalogs and technical brochures

  1. ARTHOSPico

    3  Pages

  2. ISTAR

    2  Pages

  3. FACILE

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.