General Specifications The NuLook FlexWall System is manufactured by Amico Corporation. The following is a general specification, and components listed may not be present or required in final product. The NuLook FlexWall System is listed by Underwriters Laboratories Inc. (UL) in Canada and the United States of America. Amico Corporation manufactures all products in accordance with the CSA Z7396.1 standard, National Fire Protection Association (NFPA), NFPA-99c (current edition), National Electric Code (NEC), and the Canadian Electrical Code (CEC). The NuLook FlexWall is Made Up of Several Integral Components: • Vertical sections where the services are located. These components have optional vertical and/or horizontal rails systems and reveals as well as 3D wrap finished front panels attached. These sections are installed on the finished wall. • Center section with removable 3D wrap panels for bed area. This component is located between the vertical sections. This section is installed on the finished wall and has optional horizontal/vertical aluminum reveals or rails. It can accommodate bed bumpers and decorative resin panels with built-in LED lights. Please refer to approved submittal drawings for project specific details. • The Engine has integrated electrical raceways and conduit, providing single point connection for all electrical power type (critical, normal and low voltage/ communication). • The Engine also has all medical gas piping which is hardpiped and brazed to a single point of connection. Job specific shop drawings shall be produced for each project. These shop drawings will clearly indicate the area of medical gas termination and electrical connection points inside the panel wall system. Built drawings will be produced and e-mailed at the time of shipment. • The frame and panels are mounted on top of the drywall and contain hoses and flex conduit which connect to the Engine with our NuLook Adapter. Amico Corporation will manufacture equipment as per signed approval drawings and verification documents which are provided in the job specific submittal pack
Open the catalog to page 1
Materials and Construction Integrated Accessory Rails (Optional) Numbers of integrated rails (horizontal and vertical) are to match final shop drawings. Accessory rails are clear etched anodized aluminum. Low Voltage Data Provisions Low voltage devices (excluding nurse call system devices) shall be connected to existing low voltage sources via flexible conduits. Nurse call patient station device shall be furnished, installed and wired by low voltage contractor. Electrical Receptacles This shall be Hospital Grade 15 or 20 amp, 120 or 277 volt, UL listed and marked hospital grade. Amico...
Open the catalog to page 2All Amico catalogs and technical brochures
-
NuLook Manifold
2 Pages
-
NuLook Casework
2 Pages
-
Recessed Console
2 Pages
-
Patient Room Furniture
12 Pages
-
Air and Vacuum Systems
20 Pages
-
Suction & Oxygen Therapy
16 Pages
-
nulook_casework
20 Pages
-
Architectural brochure
24 Pages
-
Accessories
20 Pages
-
Rigid (Stationary) LITE
2 Pages
-
Surface Mount Console Unit
2 Pages
-
Majestic Series
3 Pages
-
arch brochure
28 Pages
-
Suction and Oxygen Therapy
16 Pages
-
Clinical Solutions 2015
20 Pages
-
Titan Series Stretcher
5 Pages
-
Patient Room Furniture brochure
16 Pages
-
MedSurg Series Beds brochure
5 Pages
-
Regal Series
3 Pages
-
Reflection Series
2 Pages
-
Freedom Series
2 Pages
-
Architectural Headwalls
28 Pages
-
Medical Gas Pipeline
16 Pages
-
Clinical Solutions
20 Pages
-
Casegoods
16 Pages
-
Laboratory Products
20 Pages
-
Teaching and Training Solutions
20 Pages