Catalog excerpts
Most effective sterilant Most efficient steriliserSeries 3: AN310 100% Ethylene Oxide Sterilisation Cabinet features: -16 - 24 hour sterilisation cycle. - 40°C to 55°C operation. - Delivers a validatable SAL of 10'6. - High capacity, multiple load machine. - Standard, Batch and Industrial modes. - Sterilise and aerate in same chamber. - 60-litre or 20-litre sterilisation bags. - Labels and cycle record printed. - Abator available. - All items CE marked. - No water or vacuum lines required Micro-Dose System: EtO is provided in glass ampoules, in plastic cartridges. When activated these release EtO directly to the heart of the load delivering a high level of sterility with a very small amount of gas. Series 3 refill kits: AN1006 kit contains 60-litre sterilisation bags, 10.5g gas cartridges, Humidichips and Dosimeters for 25 cycles. For small loads the AN1005 kit contains 20-litre sterilisation bags and 5.0g cartridges. ANDERSEN PRODUCTS the future of gas sterilisation The high throughput capacity of the Series 3 multi-load steriliser means it is used principally in hospitals and by medical device manufacturers. They find that the Series 3 reduces equipment turnaround time and saves cost compared to sending out to a contractor. Hospitals enjoy the multi-load flexibility, and they also extend the life of equipment that had previously been damaged by other sterilisation technologies. Medical device manufacturers make use of custom validation to run precisely the right conditions for their product. Typically they manufacture high value, low volume items such as sutures, intra-ocular lenses and brachytherapy strings. VJ
Open the catalog to page 1Vacuum sealer (AN-5027.11) The AN-5027.11 is a temperature controlled pneuma�c, impulse heat vacuum sealer with gas purge capability and digital vacuum level control. The sealer is controlled by a full digital high-speed PLC controller with a color enhanced LCD Touch screen HMI. The AN-5027.11 vacuum sealer has two retrac�ng nozzles and is standard with upper heat. Op�onal dual heat model has selectable Upper heat only or Upper and lower heat. There are five selectable sealing modes for opera�on. Se�able heat seal parameters are: sealing temperature, sealing �me (dwell), release temperature...
Open the catalog to page 2All Andersen Products catalogs and technical brochures
-
EOGas4
4 Pages
-
EOGas3 - AN333
2 Pages
-
Anprolene AN75
2 Pages
-
EOGas3 - Abator
2 Pages
-
EoGas 3 - Refill Kits
2 Pages
-
EOGas3 - Range
2 Pages
-
EOGas3 - Zero Emission
2 Pages
-
EOGas4 - Zero Emission
2 Pages
-
EOGas4
2 Pages
-
Abator Anprolene & EOGas 4
2 Pages