Group: Oxford Instruments
Catalog excerpts
an Oxford Instruments company P THE detector for single molecule detection P NEW SRRF-Stream - Real time super-resolution from a camera P Lowest phototoxicity of living cells - longer observation time Lowest fluorophore concentrations - accurate physiology P Stunning price/performance Exclusively for Fluorescence Microscopy
Open the catalog to page 1an Oxford Instruments company Introducing iXon Life EMCCD ultrasensitivity...breakthrough price! Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity with absolutely unparalleled price/performance. Available in 1024 x 1024 and 512 x 512 sensor formats, each back-illuminated, to deliver the highest and broadest QE of any microscopy camera, and deep cooled down to -80oC for minimal darkcurrent, iXon Life represents a way to access, quite simply, the ultimate...
Open the catalog to page 2an Oxford Instruments company What difference can the iXon Life EMCCD make? The new iXon Life delivers on the key attributes of ultra-sensitivity that thousands of Andor iXon EMCCD customers have been benefiting from for many years: p Single Molecule Detection - Single molecule experiments present us with the considerable challenge of harnessing the limited photon budget from dynamic, individual fluorescent molecules, while also avoiding photobleaching. Andor iXon EMCCDs have continued to radically out-perform sCMOS detectors in this most demanding of light starved application...
Open the catalog to page 3Application Focus Single Molecule Detection For many years, Andor’s iXon EMCCDs have been the gold standard detectors of the biophysics laboratory. To this day they remain the dominant detector type, operating in a low light regime that is less suited to even back-illuminated sCMOS cameras, especially under the critically demanding conditions of minimized fluorophore photobleaching. The accelerated readout rates of the iXon Life, especially combined with ‘Optically Centred Crop Mode’, means that dynamic single molecule processes can be better characterised. The 13 μm pixel of the 888 model...
Open the catalog to page 4an Oxford Instruments company Technical SpecificationsSystem Specifications * iXon Life 888 Sensor Active pixels Pixel size Image area Pixel Readout Rate Minimum temperature, air cooled, ambient 20°C Chiller liquid cooling, coolant @ 10°C, >0.75l/min Thermostatic Precision Triggering System window type Blemish specification Digitization PC Interface Lens Mount
Open the catalog to page 5an Oxford Instruments company iXon Life 888 - Frame RatesStandard Mode Array size Crop Mode - (Optically Centred frame rates in brackets) Array size Quantum Efficiency (QE) Curve •”QE vs. Fluorophore Emissions 100 90 80 70 g 60 s o 1 50 I 40 30 20 10
Open the catalog to page 6Step 3. Select the required software Software The iXon Life series requires one of the following software options: Solis Imaging A 32-bit and fully 64-bit enabled application for Windows (7, 8, 8.1 and 10) offering rich functionality for data acquisition and processing. AndorBasic provides macro language control of data acquisition, processing, display and export. Andor SDK A software development kit that allows you to control the Andor range of cameras from your own application. Available as 32 and 64-bit libraries for Windows (7, 8, 8.1 and 10), compatible with C/C++, C#, Delphi, VB.NET,...
Open the catalog to page 7an Oxford Instruments company Product Drawings Dimensions in mm [inches] iXon Life 897 PIXEL 1:1 THREADED BUSH FOR C-MOUNT ' MOUNTING POINTS 1/4 - 20 UNC X 12.7 [0.500] DEEP 8 PLCS ■MOUNTING POINTS M5 X 5.0 [0.370] DEEP 4 PLCS iXon Life 888 Power RequirementsiXon Life 897 Power Requirements • Power Input: +12 VDC ± 5% @ 8 A • Power Consumption: 96 W max • Ripple and noise: 120 mV max (peak-peak 0 - 20 MHz) • External Power Supply: 100 - 240 VAC 50/60 Hz • Power Input: +12 VDC ± 5% @ 6 A • Power Consumption: 72 W max • Ripple and noise: 120 mV max (peak-peak 0 - 20 MHz) • External Power...
Open the catalog to page 8ORDER TODAY Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our local sales offices, please see: andor.com/contact Our regional headquarters are: Europe Belfast, Northern Ireland Phone +44 (28) 9023 7126 Fax +44 (28) 9031 0792 North America China Concord, MA, USA Beijing Phone +1 (860) 290 9211 Phone +86 (10) 8271 9066 Fax +1 (860) 290 9566 Fax +86 (10) 8271 9055 Items shipped with your iXon...
Open the catalog to page 9All Andor Technology PLC catalogs and technical brochures
-
Zyla sCMOS
78 Pages
-
iXon Ultra
121 Pages
-
Andor_Newton
44 Pages
-
Kymera_328i
63 Pages
-
Solis 64
6 Pages
-
ikon xl 231
8 Pages
-
zyla 5.5 scmos
12 Pages
-
ixon ultra 888
12 Pages
-
ikon xl 230
8 Pages
-
2020 Neo 5.5 sCMOS
6 Pages
-
Multi-Wavelength Imaging
11 Pages
-
2017 iXon EMCCD
13 Pages
-
iKon-L HF
7 Pages
-
Shamrock 500 Spectrograph
13 Pages
-
Shamrock 750 Spectrograph
14 Pages
-
iXon Ultra 888 EMCCD
2 Pages
-
iXon Ultra 897 EMCCD
2 Pages
-
iKon-M CCD for Photovoltaics
6 Pages
-
Zyla 5.5 HF
8 Pages
-
Neo 5.5 sCMOS
6 Pages
-
Microspectroscopy Gatefold
8 Pages
-
Kymera 193 Spectrograph
14 Pages
-
iKon-XL 230
8 Pages
-
iKon-XL 231
8 Pages
-
Imaris Gatefold
8 Pages
-
Spectroscopy
25 Pages
-
High Energy Detection
28 Pages
-
Clara CCD
2 Pages
-
Spectroscopy Solutions
23 Pages
-
Neo and Zyla sCMOS Cameras
17 Pages
-
iXon EMCCD
13 Pages