video corpo

iDus Spectroscopy CCD 416 Series
6Pages

{{requestButtons}}

Catalog excerpts

iDus Spectroscopy CCD 416 Series - 1

30 x 3.8 mm / 2000 x 256 pixel NIR Spectroscopy CCD ANDOR an Oxford Instruments company Features and Benefits • Low dark current 10x better than Back-Illuminated Deep-Depletion NIMO sensors, best SNR in the NIR • Peak QE up to 95% Best detection capability in the NIR • 15 pm pixels Ideal for high resolution spectroscopy • 30 mm wide sensor Superior simultaneous band-pass capture • Fringe suppression technology as standard Optical etalonning virtually eliminated • TE cooling down to -95oC Critical for elimination of dark current detection limit - no inconvenience associated with LN2 • UltravacTMM Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance year after year • USB 2.0 connection Ideal for laptop operation Seamless operation alongside USB-based Shamrock spectrograph family • Compact and rugged platform Ideal for OEM integration & laboratory setups • Solis software for Spectroscopy Comprehensive, user-friendly interface for simultaneous detector & spectrograph control • Software Development Kit (SDK) Ease of control integration into complex setups: Matlab, Labview, Visual Basic or C/C++ The most sensitive NIR CCD platform on the market Andor’s new iDus 416 platform boasts a unique combination of very low dark noise and very high QE, offering unrivalled sensitivity in the near-infrared. This makes it the ideal detector for NIR Raman and Photoluminescence, reducing greatly acquisition times and removing the need for inconvenient LN2 cooling. The unique 2000 x 256, 15 pm pixel array allows extended, broadband and high resolution spectral acquisition, while the fringe suppression technology virtually eliminates the optical etalonning at the higher wavelengths. With its compact form factor and USB 2.0 connectivity, the iDus 416 can be seamlessly integrated to Shamrock USB 2.0 spectrographs and controlled from a laptop. Andor’s UltraVac™ technology carries a unique track record when it comes to performance and reliability, maintaining superb performance year after year for both Research users and industrial integrators.

Open the catalog to page 1
iDus Spectroscopy CCD 416 Series - 2

ANDOR an Oxford Instruments company Key Specifications -2 Model number Have you found what you are looking for? Need a larger sensor for multi-track spectroscopy? The iDus 420 series is available with 26.6 x 6.6 mm format and 1024 x 255 pixels. Need to work further into the NIR? The iDus InGaAs series, with up to 1024 pixel linear array with transmission to 2.2 pm. Need a faster or more sensitive CCD? The Newton series offers over 1,600 spectra per second and EM technology. Need more UV sensitivity? The iDus 420 offers a range of UV optimized sensors. Need a customized version? Please...

Open the catalog to page 2
iDus Spectroscopy CCD 416 Series - 3

iDus 416 Series Dark Current Quantum Efficiency Curves Standard 15 µm pixel, BackIlluminated, Deep-Depletion ('NIMO') iDus 416 Low Dark Current DeepDepletion Dark current (e-/pixel/s) Standard 15 µm pixel, BackIlluminated, Back-Thinned ('AIMO') Typical Setup Quantum Efficiency Curves Alternative Detector Power Supply Quantum efficiency (%) Customizable & Flexible For industrial applications, the iDus 416 offers various levels of customization based around the following: • Lockable USB • Alternative water connections (90 degrees) • Chassis mounting options Please contact us to discuss your...

Open the catalog to page 3
iDus Spectroscopy CCD 416 Series - 4

ANDOR an Oxford Instruments company Creating the Optimum Product for youStep 1. Cooling Step 2. Camera Window Choose the cooling option Description Select an alternative camera window (optional) The standard window has been selected to satisfy most applications. However, other options are available. The alternative camera window code must be specified at time of ordering. To view and select other window options please refer to the ‘Camera Windows Supplementary Specification Sheet’ which gives the transmission characteristics, product codes and procedure for entering the order. Further...

Open the catalog to page 4
iDus Spectroscopy CCD 416 Series - 5

ANDOR an Oxford Instruments company Product Drawings Dimensions in mm [inches] Third-angle projection ■ = position of pixel 1,1 Weight: 2 kg [4 lb 8 oz] NOTE: There are 2x holes: 1x on top and 1x on the bottom of the camera head Imperial: 1 /4-20 UNC screw max depth 1 Minch Mounting hole locations Connecting to the iDus Camera Control Connector type: USB 2.0 TTL / Logic Connector type: SMB, provided with SMB - BNC cable Fire (Output), External Trigger (Input), Shutter (Output) I2C connector Compatible with Fischer SC102A054-130 1 = Shutter (TTL), 2 = I2C Clock, 3 = I2C Data, 4 = +5 Vdc, 5 =...

Open the catalog to page 5
iDus Spectroscopy CCD 416 Series - 6

Order Today Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our andor.com/contact local sales offices, please see: Our regional headquarters are: Europe Japan Belfast, Northern Ireland Tokyo Phone +44 (28) 9023 7126 Phone +81 (3) 6732 8968 Fax +44 (28) 9031 0792 Fax +81 (3) 6732 8939 North America China Concord, MA, USA Beijing Phone +1 (860) 290 9211 Phone +86 (10) 8271 9066 Fax +1 (860) 290...

Open the catalog to page 6

All Andor Technology PLC  catalogs and technical brochures

  1. Zyla sCMOS

    78 Pages

  2. iXon Ultra

    121 Pages

  3. Andor_Newton

    44 Pages

  4. Kymera_328i

    63 Pages

  5. Solis 64

    6 Pages

  6. ikon xl 231

    8 Pages

  7. zyla 5.5 scmos

    12 Pages

  8. ixon ultra 888

    12 Pages

  9. ikon xl 230

    8 Pages

  10. iKon-L HF

    7 Pages

  11. Zyla 5.5 HF

    8 Pages

  12. iKon-XL 230

    8 Pages

  13. iKon-XL 231

    8 Pages

  14. Spectroscopy

    25 Pages

  15. Clara CCD

    2 Pages

  16. iXon EMCCD

    13 Pages