Group: Oxford Instruments
Catalog excerpts
Modular Solutions for Microspectroscopy Adding analytical dimension to microscopy images Including the new Kymera platform
Open the catalog to page 1Key Applications Micro-Raman (stimulated, SERS, TERS) Micro-Photoluminescence / Fluorescence Dark-field scattering spectroscopy Single Molecule spectroscopy Spectrally-resolved microfluidics Semiconductors / Graphene / carbon nanotubes study Bio-sample screening - e.g. cancer tissues Features and Benefits High sensitivity detectors Ultra-sensitive CCD, ICCD, EMCCD and sCMOS cameras for maximum photon detection and speed. Ideal for fast and photon starved chemical mapping or microfluidics setups. Highly configurable spectrograph platforms Extensive range of multi-input and output, motorized...
Open the catalog to page 2Fiber-optic coupling Direct C-mount Enclosed optical relay Detector CCD, EMCCD, ICCD, InGaAs Microscope Inverted side port or upright port Open cage system Software Solis, SDK, ^Manager Direct coupling Male C-mount Lowest Side, upright* Cage system** Male C-mount or free space Cage adapter User User configuration- configuration- Side, upright* dependant dependant (*) Custom positioning setup required, e.g. elevated support structure. (**) Fixed configuration enclosed optical relay are also available on request.
Open the catalog to page 3Research-grade spectrographs Highly modular motorized platforms with dual output ports, dual/triple/quadruple grating turrets and a wide range of motorized and field-upgradable accessories. Shamrock 500i High resolution modular spectrograph Shamrock 750 Highest resolution modular spectrograph Kymera 328i NEW Intelligent and multimodal ‘workhorse’ spectroscopy platform Shamrock 163 Compact manual benchtop spectrograph Kymera 193i NEW Intelligent, modular and compact imaging spectrograph Find out more at andor.com/spectrographs Kymera 328i - Intelligent and multi-modal spectroscopy platform...
Open the catalog to page 4Wide Aperture Slit - Combining sample imaging and spectral analysis through the same optical path. ‘Infinity-corrected’ microscope ports exhibit a quasi-collimated output beam with F/number typically greater than F/20. When this beam is relayed at the entrance slit of an ‘imaging-corrected’ spectrograph through direct coupling or low magnification optical arrangement, high fidelity images of the sample under the microscope objective can be acquired. Step 1: Sample image visualization • Spectrograph input slits are opened widely • Grating (or flat mirror) is positioned at the ‘zero’ order,...
Open the catalog to page 5Market-leading detectors Best matching requirements for sensitivity at wavelengths of interest, acquisition speed and time-resolution. 100 ‘Low-dark current deepdepletion’ (LDC-DD) CCD Broadband ‘Dual AR’ (BEX2-DD) and UV-VIS CCDs High sensitivity and high speed EMCCDs iDus InGaAs SWIR Spectroscopy with hassle-free TE-cooling Find out more at andor.com/cameras Zyla sCMOS Ultrafast acquisitions up to 27,000 sps, high sensitivity and high dynamic range iStar ICCD ns-gated ICCD detector for fast transient phen
Open the catalog to page 6A 64-bit enabled application for Windows (7, 8, 8.1 and 10) offering rich functionality for data acquisition and processing, as well as simultaneous control of Andor cameras, spectrographs and motorized accessories. A software development kit that allows control of Andor detection systems from your own application. Compatible as 32 and 64 bit libraries for Windows (7, 8, 8.1 and 10). Linux ^Manager Integrated microspectroscopy setup software control with seamless access to all market leading motorized microscope and accessories. Integrated sequence builder and macro interfaces for...
Open the catalog to page 7Customer Support Andor products are regularly used in critical applications and we can provide a variety of customer support services to maximize the return on your investment and ensure that your product continues to operate at its optimum performance. Andor has customer support teams located across North America, Asia and Europe, allowing us to provide local technical assistance and advice. Requests for support can be made at any time by contacting our technical support team at andor.com/support. Andor offers a variety of support under the following format: • On-site product specialists...
Open the catalog to page 8All Andor Technology PLC catalogs and technical brochures
-
Zyla sCMOS
78 Pages
-
iXon Ultra
121 Pages
-
Andor_Newton
44 Pages
-
Kymera_328i
63 Pages
-
Solis 64
6 Pages
-
ikon xl 231
8 Pages
-
zyla 5.5 scmos
12 Pages
-
ixon ultra 888
12 Pages
-
ikon xl 230
8 Pages
-
2020 Neo 5.5 sCMOS
6 Pages
-
Multi-Wavelength Imaging
11 Pages
-
2017 iXon EMCCD
13 Pages
-
iKon-L HF
7 Pages
-
Shamrock 500 Spectrograph
13 Pages
-
Shamrock 750 Spectrograph
14 Pages
-
iXon Ultra 888 EMCCD
2 Pages
-
iXon Ultra 897 EMCCD
2 Pages
-
iKon-M CCD for Photovoltaics
6 Pages
-
Zyla 5.5 HF
8 Pages
-
Neo 5.5 sCMOS
6 Pages
-
Kymera 193 Spectrograph
14 Pages
-
iKon-XL 230
8 Pages
-
iKon-XL 231
8 Pages
-
Imaris Gatefold
8 Pages
-
Andor iXon Life EMCCD
9 Pages
-
Spectroscopy
25 Pages
-
High Energy Detection
28 Pages
-
Clara CCD
2 Pages
-
Spectroscopy Solutions
23 Pages
-
Neo and Zyla sCMOS Cameras
17 Pages
-
iXon EMCCD
13 Pages