Fibre-optic sCMOS Ultrafast and high resolution Indirect Detection Key Specifications • 100 fps & New 40 fps USB 3.0 • 5.5 MP high resolution sCMOS • High throughput fibre-optic coupling • Down to 0.9 e- read noise • New >30 lp/mm resolution with YAG:Ce or LuAG:Ce scintillators P X-Ray Tomography P Neutron Tomography P X-Ray Plasma Diagnostics P Transmission Electron Microscopy (TEM) P X-Ray Imaging P X-Ray Diff
Open the catalog to page 1Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Introducing Zyla-HFZyla Fibre Optic sCMOS- X-Ray Imaging at 100 fps Andor’s Zyla-HF outstanding design delivers the highest transmission and spatial resolution performance associated with state-of-the-art single fibre optic plate bonding, while also taking advantage of the very fast frame rate, ultra-low noise performance and exceptional field of view of the Zyla-HF. Its compact format, multiple mounting points and modular input configuration for scintillators or Beryllium filter...
Open the catalog to page 2Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company sCMOS technology: high speed AND low noise AND large field of view 14 mm Scientific CMOS overcomes the limitation of traditional slow-scan CCDs or interline technologies by offering simultaneously a large 16.6 x 14 mm (5.5 Megapixel) field of view with high resolution 6.5 pm pixel,100 frames per second and ultralow 0.9 e- read noise. Left: Zyla 5.5-HF offers a wide field of view Array Size Zyla 5.5: 10-tap (USB 3.0) Rolling Shutter Global Shutter -Above: Zyla 5.5-HF delivers exceptionally...
Open the catalog to page 3Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Technical SpecificationsSensor Specifications2 Sensor type Advanced Performance Specifications2 Sensor Operating Temperature Frame Rate Table - 12-Bit (16-Bit)'7 Fibre Optic Plate9 EMA Design For more information please refer to page 3.
Open the catalog to page 4Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Sensor Quantum Efficiency Curve M Image of a wasp acquired with and a 20 pm thick YAG:Ce scintillator fibre-optic coupled to a Zyla HF (10 s exposure) X-ray source Cu target, 40 keV, 2 W Image courtesy of Crytur YAG:Ce 20 pm thick on 3 mm FOP SCT-YAGCE -25-020-00 LuAG:Ce 20 pm thick on 3 mm FOP SCT-LUAGCE -25-020-00 Best suited for broad 2-100 keV range Best suited for 10-100 keV range YAG:Ce 70 pm thick on 3 mm FOP SCT-YAGCE -25-070-00 LuAG:Ce 70 pm thick on 3 mm FOP SCT-LUAGCE -25-070-00...
Open the catalog to page 5Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Creating The Optimum Product for You ZYLA-5.5 iXi-FO example shown Select the camera type and connection Camera Type Step 2. Select the required accessories Description For further information on PC workstations for Zyla, please refer to the technical note 3C Specifications for sCMOS Step 3. Select the required software The Zyla-HF also requires at least one of the following software options: Solis for Imaging A 32-bit and fully 64-bit enabled application for Windows (7, 8, 8.1 and 10)...
Open the catalog to page 6Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Product drawings Dimensions in mm [inches] Third-angle projection Notes • Protective cap MEC-08309 not shown • Optional Scintillator/Be Filter Holder is attached by M4 x 16 caphead screws (4 off). Connecting to the Zyla Camera Control Connector type: 3 meter Camera Link 10-tap connectors or USB 3.0. (Longer lengths available as accessories). TTL / Logic Connector type: 15 way D Type with TTL I/Os for External Trigger, Frame Readout and Fire Pulse Best Practice Guidelines P Camera is...
Open the catalog to page 7Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Order Today www.andor.com/contact Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our regional sales offices, please see: Our regional headquarters are: Europe Belfast, Northern Ireland Phone +44(28)9023 7126 Fax +44 (28) 9031 0792 Items shipped with your camera: For Camera Link 10-Tap Models:1...
Open the catalog to page 8All Andor Technology PLC catalogs and technical brochures
-
Zyla sCMOS
78 Pages
-
iXon Ultra
121 Pages
-
Andor_Newton
44 Pages
-
Kymera_328i
63 Pages
-
Solis 64
6 Pages
-
ikon xl 231
8 Pages
-
zyla 5.5 scmos
12 Pages
-
ixon ultra 888
12 Pages
-
ikon xl 230
8 Pages
-
2020 Neo 5.5 sCMOS
6 Pages
-
Multi-Wavelength Imaging
11 Pages
-
2017 iXon EMCCD
13 Pages
-
iKon-L HF
7 Pages
-
Shamrock 500 Spectrograph
13 Pages
-
Shamrock 750 Spectrograph
14 Pages
-
iXon Ultra 888 EMCCD
2 Pages
-
iXon Ultra 897 EMCCD
2 Pages
-
iKon-M CCD for Photovoltaics
6 Pages
-
Neo 5.5 sCMOS
6 Pages
-
Microspectroscopy Gatefold
8 Pages
-
Kymera 193 Spectrograph
14 Pages
-
iKon-XL 230
8 Pages
-
iKon-XL 231
8 Pages
-
Imaris Gatefold
8 Pages
-
Andor iXon Life EMCCD
9 Pages
-
Spectroscopy
25 Pages
-
High Energy Detection
28 Pages
-
Clara CCD
2 Pages
-
Spectroscopy Solutions
23 Pages
-
Neo and Zyla sCMOS Cameras
17 Pages
-
iXon EMCCD
13 Pages