video corpo

Zyla 5.5 HF
8Pages

{{requestButtons}}

Catalog excerpts

Zyla 5.5 HF - 1

Fibre-optic sCMOS Ultrafast and high resolution Indirect Detection Key Specifications • 100 fps & New 40 fps USB 3.0 • 5.5 MP high resolution sCMOS • High throughput fibre-optic coupling • Down to 0.9 e- read noise • New >30 lp/mm resolution with YAG:Ce or LuAG:Ce scintillators P X-Ray Tomography P Neutron Tomography P X-Ray Plasma Diagnostics P Transmission Electron Microscopy (TEM) P X-Ray Imaging P X-Ray Diff

Open the catalog to page 1
Zyla 5.5 HF - 2

Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Introducing Zyla-HFZyla Fibre Optic sCMOS- X-Ray Imaging at 100 fps Andor’s Zyla-HF outstanding design delivers the highest transmission and spatial resolution performance associated with state-of-the-art single fibre optic plate bonding, while also taking advantage of the very fast frame rate, ultra-low noise performance and exceptional field of view of the Zyla-HF. Its compact format, multiple mounting points and modular input configuration for scintillators or Beryllium filter...

Open the catalog to page 2
Zyla 5.5 HF - 3

Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company sCMOS technology: high speed AND low noise AND large field of view 14 mm Scientific CMOS overcomes the limitation of traditional slow-scan CCDs or interline technologies by offering simultaneously a large 16.6 x 14 mm (5.5 Megapixel) field of view with high resolution 6.5 pm pixel,100 frames per second and ultralow 0.9 e- read noise. Left: Zyla 5.5-HF offers a wide field of view Array Size Zyla 5.5: 10-tap (USB 3.0) Rolling Shutter Global Shutter -Above: Zyla 5.5-HF delivers exceptionally...

Open the catalog to page 3
Zyla 5.5 HF - 4

Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Technical SpecificationsSensor Specifications2 Sensor type Advanced Performance Specifications2 Sensor Operating Temperature Frame Rate Table - 12-Bit (16-Bit)'7 Fibre Optic Plate9 EMA Design For more information please refer to page 3.

Open the catalog to page 4
Zyla 5.5 HF - 5

Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Sensor Quantum Efficiency Curve M Image of a wasp acquired with and a 20 pm thick YAG:Ce scintillator fibre-optic coupled to a Zyla HF (10 s exposure) X-ray source Cu target, 40 keV, 2 W Image courtesy of Crytur YAG:Ce 20 pm thick on 3 mm FOP SCT-YAGCE -25-020-00 LuAG:Ce 20 pm thick on 3 mm FOP SCT-LUAGCE -25-020-00 Best suited for broad 2-100 keV range Best suited for 10-100 keV range YAG:Ce 70 pm thick on 3 mm FOP SCT-YAGCE -25-070-00 LuAG:Ce 70 pm thick on 3 mm FOP SCT-LUAGCE -25-070-00...

Open the catalog to page 5
Zyla 5.5 HF - 6

Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Creating The Optimum Product for You ZYLA-5.5 iXi-FO example shown Select the camera type and connection Camera Type Step 2. Select the required accessories Description For further information on PC workstations for Zyla, please refer to the technical note 3C Specifications for sCMOS Step 3. Select the required software The Zyla-HF also requires at least one of the following software options: Solis for Imaging A 32-bit and fully 64-bit enabled application for Windows (7, 8, 8.1 and 10)...

Open the catalog to page 6
Zyla 5.5 HF - 7

Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Product drawings Dimensions in mm [inches] Third-angle projection Notes • Protective cap MEC-08309 not shown • Optional Scintillator/Be Filter Holder is attached by M4 x 16 caphead screws (4 off). Connecting to the Zyla Camera Control Connector type: 3 meter Camera Link 10-tap connectors or USB 3.0. (Longer lengths available as accessories). TTL / Logic Connector type: 15 way D Type with TTL I/Os for External Trigger, Frame Readout and Fire Pulse Best Practice Guidelines P Camera is...

Open the catalog to page 7
Zyla 5.5 HF - 8

Ultrafast and high resolution Indirect Detection Fibre-optic sCMOS ANDOR an Oxford Instruments company Order Today www.andor.com/contact Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our regional sales offices, please see: Our regional headquarters are: Europe Belfast, Northern Ireland Phone +44(28)9023 7126 Fax +44 (28) 9031 0792 Items shipped with your camera: For Camera Link 10-Tap Models:1...

Open the catalog to page 8

All Andor Technology PLC  catalogs and technical brochures

  1. Zyla sCMOS

    78 Pages

  2. iXon Ultra

    121 Pages

  3. Andor_Newton

    44 Pages

  4. Kymera_328i

    63 Pages

  5. Solis 64

    6 Pages

  6. ikon xl 231

    8 Pages

  7. zyla 5.5 scmos

    12 Pages

  8. ixon ultra 888

    12 Pages

  9. ikon xl 230

    8 Pages

  10. iKon-L HF

    7 Pages

  11. iKon-XL 230

    8 Pages

  12. iKon-XL 231

    8 Pages

  13. Spectroscopy

    25 Pages

  14. Clara CCD

    2 Pages

  15. iXon EMCCD

    13 Pages