QA3 Emergency Trolley - 9 Pages

Add to MyMedicalExpo favorites
QA3 Emergency Trolley

Catalog excerpts

Emergency Trolley Radiotranslucent platform with exceptional X-ray access and low height capability

 Open the catalog to page 1

QA3 EMERGENCY TROLLEY SYSTEM: Four new models to choose from Powered $ Emergency Trolley Powered $ Emergency Trolley Specially designed for Emergency Departments with radiotranslucent platform, offering exceptional X-ray access as well as a medirail and K8 pressure care mattress. Description    Code with Radiolucent Platform Featuring inbuilt motorised drive - operated by innovative touch-sensitive pushing handles: controlled, effortless travel up to gradients of 10° Description    Code QA3 DRIVE Emergency Trolley    21122 with Radiolucent Platform Electrically powered positioning raises or...

 Open the catalog to page 2

STANDARD FEATURES Pushing handles Specially designed QA3 Emergency Trolley features a radiotranslucent platform, exceptional X-ray access and low height capability. Comes complete with a medirail and the K8 pressure care mattress. four ergonomically positioned pushing handles for supreme manoeuvrability With maximum patient comfort built in, the trolley is supremely manoeuvrable, compact, light weight and robust. All Emergency trolleys are fitted with two fixed transfusion poles and a medirail. unique design, precision controlled, easy lift system for enhanced user and patient comfort...

 Open the catalog to page 3

Inbuilt motorised drive offers effortless movement combined with ultimate control. Because people and therefore patients are getting larger, it's crucial that we take moving and handling issues into account, giving practitioners a trolley on which patients can be moved and positioned as easily as possible. The introduction of our new touch-activated, motorised DRIVE feature offers a major enhancement in a trolley that already has ease of use, practicality and patient comfort built in. The trolley can also be used in traditional fifth wheel steer mode. QA3IIIIIDRIVEEmergency Trolley QA3...

 Open the catalog to page 4

Another option developed to help minimise risks for practitioners dealing with increasing patient weights is powered positioning. With these models, either the whole trolley platform or the backrest can now be raised or lowered electronically from the panel at the foot end. There's also a special CPR feature: return the trolley swiftly to a horizontal, optimal height position for CPR treatment, at the touch of a button. Platform height - electrically powered raise and lower mechanism Offers smooth movement to position the trolley at any point in its height range - 535mm to 835mm (excluding...

 Open the catalog to page 5

QA3    QA3IIIIDRIVE Emergency Trolley    Emergency Trolley QA3 Powered $ Emergency Trolley QA3 IIIIDRIVE Powered $ Emergency Trolley QA3 '< 800for Bariatric Patients Increased platform/mattress - width: 800mm Again recognising the trend for increasing patient weights and sizes, we offer special Bariatric versions of the QA3. The extra wide (800mm) platform significantly increases the surface area for added safety and comfort for Bariatric patients. Increased surface area Pressure care mattress As with all of our trolleys, the QA3 < 800 > is fitted with the K8 pressure care mattress. At its...

 Open the catalog to page 6

Normal Mattress K8 Pressure Care Mattresses Pressure care and infection control are top priorities in a trolley mattress – and Anetic Aid’s independently tested K8 pressure care mattress addresses both of these vital factors. At its core is high density foam, uniquely specified by Anetic Aid. This means that the mattress can be thinner, while still offering the same, if not better, pressure distribution than a thicker, less sophisticated foam. This is particularly important with tables and trolleys, as it means the overall height can be kept as low as possible for easy access by frail or...

 Open the catalog to page 7

QA3    QA3IIIIDRIVE Emergency Trolley    Emergency Trolley QA3 Powered $ Emergency Trolley QA3 IIIIDRIVE Powered $ Emergency Trolley LIFETIME WARRANTY Subject to annual servicing QA3 Trolley System: we offer the unique and popular ‘Lifetime Warranty Scheme’ Take out a service package for regular maintenance costs, fixed for 10 years, including a 10 YEAR WARRANTY Covers engineer's time and most parts - also ask about our maintenance programmes Value for money: minimum downtime, maximum peace of mind

 Open the catalog to page 8

Emergency Trolley Specifications Standard features X-ray translucent platform – full length radiotranslucent platform, suitable for digital or traditional plates Overall width: 835mm (side rails up) 735mm (side rails down) Hydraulic lift mechanism – exceptional low height capability Height range excluding mattress: 535mm to 835mm Latest castor technology – low rolling resistance for high manoeuvrability Pushing handles – ergonomically positioned Maximum patient weight: 320kg (Please refer to user manual) Cylinder trough – side loading Please refer to ‘Instructions for Use’ for full product...

 Open the catalog to page 9