1. Catalogs
  2. Angell Technology
  3. WR-3D Brochure 2023v08.03

WR-3D Brochure 2023v08.03

WR-3D Brochure 2023v08.03

WR-3D Brochure 2023v08.03

Product catalog summary
Introduction
The WR-3D Weight-Bearing Radiographic 3D System by Shenzhen Angell Technology Co., Ltd. offers advanced imaging capabilities that differ significantly from traditional CT and MRI, which are limited to supine positions. This system provides unique clinical value by capturing 3D imaging in weight-bearing positions, crucial for diagnosing and planning treatments for spine, pelvis, and lower extremity conditions.

Specifications
The WR-3D system supports whole-body part scans, including cervical spine, lumbar spine, ankle, knee joint, hip joint, and airway. It features low-dose weight-bearing 3D imaging, offering a more accurate reflection of joint states under weight-bearing conditions. The system boasts the industry's largest field of view (FOV) at 350mm and can complete single-part scanning and reconstruction within 3 minutes, the fastest in the industry.

Imaging and Reconstruction
Utilizing cone beam CT technology, the WR-3D system performs real 3D scanning and reconstruction. It supports 2D+3D one-stop examinations and maintains existing DR equipment workflows. The system can reconstruct tomographic images and supports MIP, MPR, and VR volume rendering applications.

Automatic Recognition and Measurement
The system includes automatic image processing technology for identifying and segmenting the entire spine, measuring key parameters such as 3D Cobb angle, vertebra rotation angles, and scoliosis assessments. It aids orthopedic surgeons in pre-diagnosis, pre-operative planning, and post-operative evaluations.

Clinical Applications
Angell Technology has launched the world's first weight-bearing full spine volume scanning imaging and foot measurement system based on WR-3D technology. This system is valuable for spinal orthopedic surgery planning and review.

Advanced Features
Future features include assessments for Total Hip Arthroplasty (THA) and Total Knee Arthroplasty (TKA), and automatic measurements for the whole lower limb, knee joint, foot, and ankle in weight-bearing positions. The system supports 3D volume scanning reconstruction of the whole lower extremity and diagnoses for conditions like atlantoaxial subspondylolisthesis and lumbar spondylolisthesis.

Automatic Measurement System
The system supports automatic measurement of 3D Cobb angles, vertebral body rotation angles, and pelvis-related parameters in weight-bearing positions. It can generate spine 3D printing templates and supports one-click measurement and report generation.
See more

Catalog excerpts

WR-3D Brochure 2023v08.03-1

Room
408,
Building
A,
Huahan
Innovation
Park, Langshan
Road,
Nanshan
District, Shenzhen
518055,
China Tel꞉
(+86)
755-86966744 Fax꞉
(+86)
755-26859389 Web꞉
www.szangel

 Open the catalog to page 1
WR-3D Brochure 2023v08.03-2

have
confirmed
that
the
3D
imaging
information
in
the
weight‑bearing
position
is
significantly
different
 from
that
in
the
supine
position,
and
the
3D
imaging
information
in
the
weight‑bearing
position
more
 truly
reflects
the
biomechanical
imaging
characteristics
of
the
human
spine,
bones
and
joints.
It
has
 unique
clinical
value
in
the
diagnosis,
operation
plan
planning
and
postoperative
follow‑up
examination
 of
diseases
related
to
spine,
pelvis
and
lower
extremities. Beyond
2D꞉ 2D+3D
one-stop
examinations WR‑3D
 supports
 2D+3D
 one‑stop
 examinations
 and
 realizes
 3D
 scanning
 and
 reconstruction
...

 Open the catalog to page 2
WR-3D Brochure 2023v08.03-3

World's
first Weight‑bearing
full
spine
volume
scanning
imaging and
measurement
system measurement
 system
 based
 on
 WR‑3D
 technology.
 It
 has
 important
 clinical
 value
 for
 the
 planning
 and
 In
the
weight‑bearing
position 3D scanning and reconstruction of the whole spine, lower limbs, and whole body unique
 method
 of
 3D
 image
 diagnosis.
 MPR
 reconstruction
 observation,
 diagnosis
 and
 through
 coronal
 plane,
 sagittal
 The
 imaging
 principle
 of
 the
 product
 is
 based
 on
 the
 WR‑3D
 cone‑ which
 truly
 realizes
 the
 3D
 scanning
 and
 reconstruction
 of
 the
 The
maximum
intensity
projection
can
clearly
reflect
the
...

 Open the catalog to page 3
WR-3D Brochure 2023v08.03-4

WR-3D
 Automatic
measurement parameters,
 and
 sagittal
 plane
 imbalance
 parameters
 at
 the
 weight-bearing
 position.
 The
 parameters
 are
 automatically
 measured,
 and
 the
 spine
 3D
 printing
 template
 can
 also
 be
 generated.
 The
 measuring
 system
 can
support
one‑click
measurement,
output
measurement
reports,
and
generated
model
can
be
printed. Cobb
angle Cobb
angle꞉
convex
left꞉
45.5° Start
cone꞉
T5 End
cone꞉
T10 Top
cone꞉
T7 Top
cone
rotation꞉
right
rotation
16.4° Top
cone
rotation꞉
right
rotation
35.4mm Angle
type꞉
coronal
projection
angle body
rotation
angle
in
weight‑bearing
position...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.