Catalog excerpts
PERFORMANCE, SIMPLICITY, FLEXIBILITY PROSTHETIC RANGE CATALOG AXIOM® FED PRIME MOVER IN IMPLANTOLOGY #
Open the catalog to page 1a PROSTHETIC COMPONENTS PACKAGING ANTHOGYR SERENITY® WARRANTY PROSTHETIC COMPONENTS Axiom® REG/PX prosthetic range Axiom® 2.8 prosthetic range CAD-CAM PROSTHETIC COMPONENTS PROSTHETIC INSTRUMENTS RECOMMENDED TIGHTENING TORQUES LIST OF MATERIALS Contents: Axiom® FED prosthetic solutions SINGLE-UNIT RESTORATION CEMENT-RETAINED PROSTHESIS SCREW-RETAINED PROSTHESIS Esthetic TITANIUM abutments CEMENT-RETAINED PROSTHESIS Temporary PEEK abutments TITANIUM abutments CERECBASE® Esthetic ZIRCONIA abutments Gold cast-on abutment Standard TITANIUM abutments Temporary TITANIUM abutments Gold cast-on...
Open the catalog to page 2STANDARD PROSTHETIC COMPONENTS SCREW-RETAINED PROSTHESIS Ø 4.0 mm Narrow Multi-Unit abutments Secondary parts P. 17 Gold cast-on abutment Ø 4.8 mm Multi-Unit abutments Standard TITANIUM abutments REMOVABLE FULL-ARCH RESTORATION Esthetic TITANIUM abutments MULTIPLE-UNIT RESTORATION CAD-CAM PROSTHETIC COMPONENTS CEMENT-RETAINED PROSTHESIS Pacific Reworkable abutment
Open the catalog to page 3W Products supplied ISTCRILEI: - Fewer intra-oral handlings. - Intra-operative time saving. W Rapid identification of each prosthetic component1. W 4 traceability labels1: - Better data transmission between practitioners involved in the patient prosthetic rehabilitation. - Optimized treatment and patient record. Examples: standard titanium abutments, healing screws, Multi-Unit abutments I COLORLESS BLISTER (NON-STERILE) Examples: esthetic titanium abutments, titanium temporary copings. w OTHER COLORLESS BLISTER (NON-STERILE) Examples: transfers, analogs, wrenches, drills. "Other colorless...
Open the catalog to page 4Meaning of the symbols on blisters with traceability: SEALING LID Red: sterile Name and address of manufacturer See instructions for use Do not re-use (disposable device) Do not use if packaging damaged EXAMPLE OF REPOSITIONABLE TRACEABILITY LABELS w Easy, intuitive reading of the product references. w Optimized component storage. 4 detachable labels Article number Batch number Product range Catalogue reference Recommended tightening torque Batch number Date of manufacture Non sterile product Compliant with EEC Directive 93/42 Manufacturer Component type (designation) Catalogue reference...
Open the catalog to page 5Recommended emergence diameter for Axiom® REG/PX/2.8 *Source: Lavergne, Bulletins et Memoires de la Societe d'Anthropologie de Paris, vol 1, serie XIII, 1974, 351-355. 0 if mesio-distal space limited 0 in first intention other possibility Meaning of the symbols used in this document: Ch: coronal height H: reference height on label Gh: gingival height from implant neck 0: diameter Ht: height of platform
Open the catalog to page 6Axiom® FE prosthetic components Ø HEALING SCREWS w Supplied Q for single-use. w Low coronal height (1 mm) available for placement under removable prosthesis. Product reference LASER MARKING ON SCREW HEAD Gh (mm) Product reference diameter gingival height Ø 3.4 Recommended suture level Coronal height 1 mm or 2 mm Gingival height 0.75 / 1.5 / 2.5 / 3.5 and 4.5 mm. Ø 5.0 Ø 6.0 A marking "F" is added for screws of Ch = 1 mm This figure shows a healing screw with 2.5 GH and a 2
Open the catalog to page 7a IMPLANT-LEVEL IMPRESSION TAKING Components Product reference Pick-up transfer - short Short and long pick-up screws included Transfer pick-up - long PICK-UP TECHNIQUE Long and extra-long pick-up screws included Body lenght 14 mm Manual Short Pick-up screw Long Pick-up screw Extra-long Pick-up screw Impression rings for Pick-up Pop-in transfer - short Pop-in screw included Body lenght 10 mm POP-IN TECHNIQUE Pop-in transfer - long Pop-in screw included Body lenght 14 mm IMPLANT ANALOG Implant analog STANDARD TITANIUM ABUTMENT-LEVEL IMPRESSION TAKING w Impression taking technique reducing...
Open the catalog to page 8TRY-IN ABUTMENTS w Medical titanium. w Tri-lobed indexation. Product reference
Open the catalog to page 9a TITANIUM TEMPORARY ABUTMENTS Temporary single-unit restoration w Retention grooves. w With tri-lobed indexation. w Supplied Q. w Reworkable. Laboratory screw Product reference
Open the catalog to page 10ESTHETIC TITANIUM ABUTMENTS Product reference SUPPLIED WITH M1.6 Black Tite® permanent screw w 6 components available. 5 w sthetic abutment shoulder. E w ulip-shaped gingival profile for abutments with T gingival height from 0.75 to 3.5 mm. w pecific gingival profile for abutments with gingival S height 4.5 mm (cf. "Particular case" hereafter). w ri-lobed indexation. T w butment disconnector/gripper, ref. INEXPL and A INEXPS, usable with product references having "Removable" mention on label. Single-Unit or multiple-unit ble emova restoration on Axiom® REG/PX implants R
Open the catalog to page 11Product reference PARTICULAR CASE: Gingival height 4.5 mm esthetic TITANIUM abutments have a specific gingival profile to be used in the following situations: w Gingival height of 4.5 mm and coronal height of 7 mm. w Gingival height of 2.5 mm and coronal height of 9 mm. w In order to obtain this abutment with a coronal height of 9 mm, w the laboratory should rework the 2 mm cylindrical par
Open the catalog to page 12PROSTHETIC SOLUTIONS AXIOM ESTHETIC ZIRCONIA ABUTMENTS* Single-unit cement-retained restoration on Axiom® REG/PX implants in anterior or posterior region W Theses abutments consist of following two pieces bonded together: titanium base and coronal part made of Sina Z® zirconia. Esthetic abutment shoulder. Tri-lobed indexation. The rework needed is minimal (for more information: see Axiom® REG/PX surgical guide). SUPPLIED WITH Product reference Not available in all countries. Please contact your Anthogyr local representative.
Open the catalog to page 13a STANDARD TITANIUM ABUTMENTS able Remov w Supplied Q for an immediate placement: - reduce intra-oral handlings. - preserve soft tissues. w Dedicated secondary components: - Specific transfers and analogs (Cf. page 8). - astable copings for single-unit or multiple-unit C restoration, no rework necessary. - Protective caps. w butment disconnector/gripper, ref. INEXPL and A INEXPS, usable with product references having «Removable» mention on label. STRAIGHT STANDARD TITANIUM ABUTMENTS: w With tri-lobed indexation. w Available in 2 coronal heights: 4 and 6 mm w Single-unit or multiple-unit...
Open the catalog to page 14All ANTHOGYR catalogs and technical brochures
-
Anthogyr CAD-CAM solutions
2 Pages
-
General practice equipment
32 Pages
-
MULTI-UNIT GE Abutments
8 Pages
-
anthofit
2 Pages
-
Brochure Axiom® Multi Level®
12 Pages
-
AxIN® overview