video corpo

Penetrometer
12Pages

{{requestButtons}}

Catalog excerpts

Penetrometer - 1

flregfapp,. OperaEs: •y'sHsf Swr-ipe-1 yyft* j LJAl VfiiiMi pLjj.

Open the catalog to page 1
Penetrometer - 2

Founded in 1922, Anton Paar today employs over 2000 people in 20 countries who manage a global business and provide the whole value chain, starting from product ideas, research and development, production, sales and application support to aftersales services. The acquisition of Petrotest by Anton Paar resulted in a unique concentration of talents and know-how. The product portfolio now covers a wide range of laboratory instruments, process technologies and automation systems, ranging from standardized QC to complex R&D solutions for the petrochemical, food, cosmetics and pharmaceutical...

Open the catalog to page 2
Penetrometer - 3

All penetration methods - All standards - One product: PNR 12 Anton Paar has the most suitable test kits for each type of measuring task. These include tests according to many standardized methods and cover a wide range of applications for the petrochemical field, chemical, pharmaceutical, cosmetics and food industries. What is consistency? With Anton Paar's penetration devices, you obtain data about the quality of pasty or creamy products, their processing characteristics or their plasticity. You can also easily gain information about the solidification and the setting of your product...

Open the catalog to page 3
Penetrometer - 4

PNR 12 meets a wide range of international standards and fulfills the repeatability and reproducibility requirements of, for example, ASTM, ISO, EN and DIN. PNR 12 has a broad application range. From high-viscosity liquids (honey) to solids (bitumen), you can determine the consistency of a wide range of materials with just one instrument. No zero-position adjustment of the system No releasing of the test body No needle tip adjustment on the sample surface (if you use a sensor plunger) No stop-watch monitoring and inaccurate manual stopping at the end of the short penetration period (only 5...

Open the catalog to page 4
Penetrometer - 5

The patented force sensor plunger (optional) will detect the surface of samples even underneath a layer of water. You no longer run the risk of errors coming from observing the reflection of the needle tip in the water bath. The automatic surface detection allows precise adjustment even by inexperienced personnel. The standardized test sequence starts automatically. Suitable samples are comparably hard materials. The jog wheel program navigation (push and turn) has a scroll function: just turn and push the wheel. With this convenient program operation you can enter test parameters, sample...

Open the catalog to page 5
Penetrometer - 6

PNR 12's versatility comes from the many different test kits which can be used with the instrument. The harder (more solid) the material is, the smaller the cone angle should be. Therefore, a needle is used for bitumen and a perforated disk penetrator is used for liquid-like samples. Oil - Gel - Ointment - Grease - Bitumen / Wax Plungers (clamping rods) Plungers serve as clamping and guide shanks for various test bodies. Unless specifically listed conditions impose restrictions, it is always possible to combine any test body with any plunger. Additional weights can be placed on the plunger...

Open the catalog to page 6
Penetrometer - 7

One Device for Every Application Petroleum industry Bitumen <200 PU Bitumen <350 PU Bitumen >350 PU Grease Petrolatum, vaseline Paraffins, waxes Food industry Agar Bread Butter, margarine, edible fats Candy, confectionery Cheese Chocolate Corned beef Cream, whipped cream Curds Dough Fruit Fruit pulp Gelatine, jelly Honey Ice cream Jam, marmelade Ketchup Marzipan, marshmellows Mayonaise Meat products, sausage Mustard Pastry Potato mash Pudding Roe (fish) Yeast Yogurt

Open the catalog to page 7
Penetrometer - 9

Note: ► All elements of these test body combinations are also available individually. ► Frequently applications may require a test body and a plunger from the above test kits only. ► For special needs there are further test kits and parts available on request. ► Examples of possible applications are listed on the previous page.

Open the catalog to page 9
Penetrometer - 10

Useful Accessories Grease sample preparation The GWM 5 automatic grease working machine simplifies the exhausting grease working procedure necessary for preparing greases and other semi-solid materials for shear stability tests. The comparison between penetration and other rheological test values for fresh, unworked and worked samples indicates the shear stability of the material. The GWM 5 grease working machine is suitable for either single or double worker operation. Exact tempering – exact results The ambient condition that influences the consistency most is the temperature. With some...

Open the catalog to page 10
Penetrometer - 11

Standard methods - Depending on the accessories Needle and Ram Penetration: ASTM D5, ASTM D1321, ISO 6873, EN 1426, EN 13179-2, DIN 51579, IP 376-A, IP 376-B, JIS K 2207, JIS K 2235 and more Cone and Disk Penetration: ASTM D217, ASTM D937, ASTM D1403, ASTM D7342, ISO 2137, IP 50, IP 179, IP 310, European Pharmacopoeia 2.9.9. and more

Open the catalog to page 11
Penetrometer - 12

© 2018 Anton Paar GmbH | All rights reserved. Specifications subject to change without notice. H61IP002EN-B