ARTISCAN Radiotherapy
12Pages

{{requestButtons}}

Catalog excerpts

ARTISCAN Radiotherapy - 1

dosimetry epid & CBCT mlc isocenters scheduler & flexi qa

Open the catalog to page 1
ARTISCAN Radiotherapy - 2

EPID & CBCT Equipment & Phantoms

Open the catalog to page 2
ARTISCAN Radiotherapy - 4

ARTISCAN 
 EPID & CBCT QA CQ MACHINE EPID QA PACK Main parameters Pixel size, Positionin Scalin Noise, Homogeneity, Uniformit Spatial linearit Signal linearit Spatial resolutio Contrast resolution Main parameters Pixel size, Scalin Slice Thickness Noise, Homogeneity, Uniformity Geometric distortion Signal linearity Spatial resolution Contrast resolutio CT number, HU constancy EPID: RT Calibration & L/R Phantom AQUILAB ; MV-QA Sun Nuclear WIP Las Vegas All manufacturers ; EPID QC PTW ; QC-3 Standard Imaging ; CBCT: CATPHAN® 500, 503, 504, 600 Phantom Laboratory ; TOR 18FG Leeds Tests Objects...

Open the catalog to page 4
ARTISCAN Radiotherapy - 5

Static Fields Main parameters Field Siz Light/Radiation Field coincidenc MLC/Isocenter coincidenc Jaws & Leafs Orthogonality, Symmetry and Sa Accuracy of Leafs Positio Transmission, Penumbra and Leakag Leaf Bank Alignment IMRT/VMAT Fields Main parameters dMLC Dosimetry IMRT Picket Fence VMAT Picket Fenc VMAT Picket Fence with errors Dose Rate Vs Gantry Speed MLC Leafs Speed 80 leafs MLCi & MLCi2, MLCi2, Agilty™, Beam Modulator® Elekta 58, 82 leafs, 160 MLC™ Siemens Healthcare Millennium™ 80 MLC, 120 MLC, HD120® MLC Varian Medical Systems ; Standards & recommendations French 2023 ANSM...

Open the catalog to page 5
ARTISCAN Radiotherapy - 6

ARTISCAN 
 ISOCENTERS QA CQ MACHINE isocenter QA pack Collimator, Gantry and Couch isocenters Winston Lutz analysis compatible with multiple phantoms to measure Position: kV-CBCT imaging isocenter Main parameters kV-CBCT Isocenter/Reference distanc kV-CBCT Isocenter siz kV-CBCT/MV Isocenters coincidence Field Center/Reference distance for each image Collimator, Gantry and Couch rotation axis/Referenc Collimator, Gantry and Couch Rotatio Angle indicators verification Mechanical isocenter Main parameters Mechanical Isocenter/Reference distanc Mechanical Isocenter siz Mechanical/MV Isocenters...

Open the catalog to page 6
ARTISCAN Radiotherapy - 7

Centralization within a single solutio Supported beam explorer Water tank 2D Matri Using ASCII files Compatible with filtered (FF), unfiltered (FFF) electron beams Homogeneous and standarpack dized imagerie analyses rt kv Dosimetry QA module stores and analyzes data to quickly determine the parameters Flatness, Symmetry, Penumbra and Field Si Non-Homogeneity, Symmetry, Penumbra, Field Si Peak Position (FFF Beams Transmission through beam modifie Monitor Units Repeatability & Output Consistency in static and dynamic condition Beam quality index stabilit Dose profile stabilit Absolute Dose...

Open the catalog to page 7
ARTISCAN Radiotherapy - 8

Main parameters Main parameters Based on EPID images analysis Field Siz Orthogonality, Symmetr Accuracy of Leafs Positio dMLC Dosimetr Picket Fence RapidAr Dose Rate Vs Gantry Speed MLC Leafs Speed Main parameters Pixel siz Noise, Homogeneity, Uniformit Spatial linearit Signal linearit Spatial resolutio Contrast resolution kV-CBCT Imaging Noise, Homogeneity, Uniformity Slice thickness Geometric distortion Signal linearity Spatial resolution Contrast resolutio CT number, HU constancy Image courtesy of Varian Medical Systems, Inc. All rights reserved Main parameters Collimator & Gantry...

Open the catalog to page 8
ARTISCAN Radiotherapy - 9

ARTISCAN 
 TOMO QA CQ MACHINE tomo qa pack Automatic Image Quality Control MVCT images for Tomo, Tomo HD®, and Radixact™ Main measured parameters Signal to Noise Rati Uniformit Geometric distortio Contras Densit Spatial resolutio Positioning accuracy Complete and consistent backup Efficient centralization of quality control data into a single solution Ability to delegate the execution of quality controls to other staff members Recording of results and reports (including screenshots of calculated parameters and evidence of tests performed) Tomotherapy® & Radixact® Accuray 
 Cheese Phantom...

Open the catalog to page 9
ARTISCAN Radiotherapy - 10

ARTISCAN 
 options Flexi qa Option Custom Test Creation of custom tests (checkboxes, dropdown lists, value entry, calculation formulas) Integrate all Machine QA in a single solution. Custom Module Selection of tests to be performed from the entire set of Packs Create your own Daily, Monthly or Annual controls. scheduler option Your quality controls at a glanc Schedule your QC tasks by user, equipment or periodicit Define your tasks and those of your collaborator Consult the schedule by device or use Set up email notification Quickly approve your reports online

Open the catalog to page 10
ARTISCAN Radiotherapy - 11

RT Calibration & L/R Phantom AQUILAB Las Vegas All manufacturer EPID QC PTW QC-3 Standard Imaging MV-QA Sun Nuclear WIP 80 leafs MLCi & MLCi2, Agilty™, Beam Modulator® Elekta 58, 82 leafs, 160 MLC™ Siemens Healthcare Millennium™ 80 MLC, 120 MLC, HD120® MLC Varian Medical Systems m3® High-Resolution MLC Brainlab Supported Files Accuray (.csv), IBA Dosimetry (.asc, .opg),
 Sun Nuclear (.prs, .snctxt), PTW (.mcc),
 Lynx (.txt) Supported Beam Explorers Water tank, 2D matrix Ball Bearing Phantoms RT Isocenter Phantom AQUILAB Ball Bearing Phantom Elekta WL Pointer Brainlab Cube Phantoms QUASAR™...

Open the catalog to page 11
ARTISCAN Radiotherapy - 12

Your contacts Julia REDOUTEY Teriiroa LIANT 250 rue Salvador Allende - 59120 Loos, France David GIBON