SYNCHRO

SYNCHRO

SYNCHRO

Product catalog summary
Introduction
The SYNCHRO TLIF Cage is a mini-invasive implant designed for lumbar interbody fusion, developed by ARCA-MEDICA in collaboration with Dr. David Fischer-Lokou. It aims to provide optimized spinal stabilization for complex spinal pathologies.

Product Overview
The SYNCHRO cage is designed for ease of insertion and optimal filling of the disc space, utilizing a joint mechanism that allows the implant to slide into the ideal position. This patented solution enhances the stability and satisfaction of patients undergoing spinal stabilization.

Indications
The SYNCHRO cage is indicated for use in cases of degenerative lumbar disc disease, degenerative instabilities, spinal stenosis, spondylolisthesis, retrolisthesis, and recurrent disc herniation.

Mechanism
The implant consists of anterior and posterior elements linked by a joint, allowing for optimized insertion. The anterior element is inserted through the foramina, with the posterior element aiding in orientation. The angle between the elements can vary from 45 to 90 degrees.

Benefits
  • Intra-operative opening and ideal disc space filling
  • Stable fusion and reliable anterior inter-vertebral space contact
  • Secures lordosis stability and opens the opposite site


Surgical Procedure
  • Radiological Orientation: Skin incision is made 1 cm laterally from the line linking the external cortical of the pedicles.
  • Pedicle Access: Ideal entry points are located at the angle between the articular facet and the processus transversus.
  • Pedicle Screws Insertion: Screws are inserted convergently, with intra-operative views guiding the process.
  • Control of Pedicle Screws Positioning: C-arm checks ensure correct procedure level and screw positioning.
  • Preparation of Disc Space: Disc space is opened and curetted, with retractors protecting the dura and nerve roots.
  • Positioning of SYNCHRO Cage: Trials are inserted until correct distraction with lordosis is achieved, and the cage is positioned to cover the anterior disc space.


Implants and Instruments
Available in PEEK and Titanium, with part numbers ranging from AMT-100-07-S to AMT-200-13-S. Complete instrumentation is available under part number AMT-500-K01.

Contact Information
ARCA-MEDICA GmbH, Rathausplatz 6, D-79395 Neuenburg, Tel.: +49 (0) 7631/748610, Email: [email protected], Web: www.arca-medica.com
See more

Catalog excerpts

SYNCHRO-1

SYNCHRO: TLIF CAGE FOR LUMBAR INTERBODY FUSION ARCA-MEDiCA Medical Implants

 Open the catalog to page 1
SYNCHRO-2

SYNCHRO: TLIF CAGE FOR LUMBAR INTERBODY FUSION SYNCHRO – product and history Dr. med. Benoît Laurent Manager ARCA-MEDICA The complex spinal pathology requires different treatment strategies, which are all patient oriented. It is ARCA-MEDICA’s goal to provide physicians and their patients with the adequate corresponding implants for the various indications and for their related specific surgical techniques. After our implant for dynamic lumbar stabilization (Le U), we are now happy to present our mini-invasive TLIF cage SYNCHRO for instrumented stabilization. To develop this cage, we worked closely...

 Open the catalog to page 2
SYNCHRO-3

SYNCHRO Indications for SYNCHRO SYNCHRO is a new type of cage for lumbar fusion with a TLIF access. In case of: ■ degenerative lumbar disc disease ■ degenerative instabilities and spinal stenosis ■ spondilolisthesis, retrolisthesis ■ disc herniation with recidive What does SYNCHRO allow? SYNCHRO ■ opens intra-operatively ■ fills ideally the disc space ■ secures a stable fusion ■ allows a reliable contact in the anterior area of the inter-vertebral space ■ secures the lordosis stability ■ opens the opposite site The implant is made of an anterior and a posterior element. Both of them are linked...

 Open the catalog to page 3
SYNCHRO-4

1. Radiological orientation 2. Pedicle access 3. Pedicle screws 4. Control of the pedicleinsertion screws positioning 1.1. On the AP radiological view, the skin incision is going 1 cm laterally from the line which links the external cortical of the pedicles. 1.2. Attention on the sagittal orientation. The points of entry of the pedicle screws are defined at the junction of the lines covering sagittally the pedicles (blue) with the convergent marker lines of the pedicles (green). 2.1. In a lateral view and 2.2. In an axial view, the ideal points of entry are located in the angle between...

 Open the catalog to page 4
SYNCHRO-5

5. Preparation of the disc 6. Positioning of the SYNCHRO cage space 5.1. and 5.2. The disc space is opened and completely curetted onto the opposite side in a way to prepare the intersomatic space. All cartilages are removed. Do not damage the integrity of the vertebral body cortical. 5.3. Retractors can be inserted medially and cranially in a way to protect the dura and the nerve roots. 6.1. and 6.2. Trials are inserted into the disc space until radiological control shows a correct distraction with lordosis. To ease the optimal positioning of the trial, when anterior part is introduced into the...

 Open the catalog to page 5
SYNCHRO-6

AP radiological image 2 levels SYNCHRO TLIF Lateral view

 Open the catalog to page 6
SYNCHRO-7

Implants Peek SYNCHRO Part number AMT-100-07-S AMT-100-08-S AMT-100-09-S AMT-100-10-S AMT-100-11-S AMT-100-12-S AMT-100-13-S AMT-200-07-S AMT-200-08-S AMT-200-09-S AMT-200-10-S AMT-200-11-S AMT-200-12-S AMT-200-13-S Visit our website Hereby you can place an order and find further informations on our products. Complete instrumentation Part number AMT-500-K01

 Open the catalog to page 7
SYNCHRO-8

ARCAMEDiCA Medical Implants Made by: ARCA-MEDICA GmbH Rathausplatz 6 D-79395 Neuenburg Tel.: +49 (0) 7631/748610 Fax: +49 (0) 7631/748611 Mail: '[email protected] Web: www.arca-med'ca.com

 Open the catalog to page 8

All ARCA-MEDICA catalogs and technical brochures

  1. SANSSOUCI

    4  Pages

  2. ARCA BONE

    4  Pages

  3. Le U

    8  Pages

  4. CERAF

    4  Pages

  5. SOURIRE PLUS

    4  Pages

  6. SOURIRE

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.