1. Catalogs
  2. Arjo
  3. MAXI MOVE

MAXI MOVE

MAXI MOVE
1 / 44 PagesView full catalog

MAXI MOVE

Product catalog summary
Introduction
The document outlines the operating and care instructions for the Maxi Move, a mobile passive lift by ARJO, emphasizing the use of ARJO-designed parts for safety and performance.
Intended Use
The Maxi Move is designed for lifting and transferring patients who cannot support themselves, suitable for hospitals and nursing homes, and should be operated by trained caregivers using ARJO slings.
Safety Instructions
Key safety warnings include using ARJO slings, conducting clinical assessments before lifting, and not exceeding the lifting capacity. The equipment should not be used in humid or wet environments.
Product Description/Function
The Maxi Move includes adjustable chassis legs, a control handset, and a dual control panel, with safety features like an emergency stop button and a battery discharge indicator.
Using the Maxi Move
Instructions cover lifting patients from chairs, beds, and the floor using various spreader bars and slings.
Care and Maintenance
Regular maintenance and cleaning are essential, with a 10-year expected lifetime for the lifter. Guidelines for sling care are provided.
Technical Specifications
Detailed specifications and dimensions are included to ensure users understand the equipment's capabilities and limitations.
Conclusion
The document concludes with a reminder to familiarize oneself with the equipment and contact ARJO for queries.
Control Handset and Dual Control Panel
The control handset allows powered motion, with a dual control panel for parallel operation. It should not be submerged in water.
Emergency and Reset Buttons
An emergency stop button halts all movement, and a reset button resumes operations and addresses overload fuse issues.
System Failure and Wind Down Facility
A System Failure Lower Override switch and a wind down facility are available for control or power failures.
Automatic Cut Out and Stop Functions
The lifter prevents lifting beyond capacity and stops lowering onto obstructions.
Battery Indicators and Minute Meter
Battery indicators show when recharging is needed, and a minute meter aids servicing.
Chassis and Attachments
Chassis legs are adjustable, and the 'Lock and Load' system allows easy attachment changes.
Lifting Procedures
Procedures for lifting from chairs and beds are detailed, ensuring patient comfort and safety.
Warnings and Safety Precautions
Ensure sling attachment clips are secure, and the spreader bar is connected before lifting. Avoid operating the leg actuator with the patient over the legs.
Maintenance and Care
Regular checks and cleaning are advised, with specific instructions for the powered DPS spreader bar.
Additional Features
Includes a folding stretcher frame and soft stretcher for portability.
Specifications and Warnings
Ensure patient stability and secure connections before lifting. Avoid skin trapping with strap guides.
Patient Scale
Designed for supervised weighing, with specific verification and battery guidelines.
Battery Management and Charging
Includes warnings for low battery and guidelines for charging and battery care.
Cleaning and Maintenance
Regular cleaning and disinfection are essential, with specific products recommended.
Operational Testing
Periodic testing of functions and regular servicing by an ARJO engineer are recommended.
Labels and Specifications
Includes maximum lifting capacity, voltage, and compliance with standards.
Specifications
Details on battery capacity, protection classes, and environmental conditions are provided.
Duty Cycle
Specifications for mast lift and chassis actuators are included.
Environmental Conditions
Details on humidity, temperature ranges, and storage conditions are provided.
Scale Specifications
Includes power supply, battery life, and accuracy details.
Maximum Capacities of Maxi Move
Details on capacities for different slings and attachments are provided.
Contact Information
Contact details for ARJO and international offices are included.
See more

Catalog excerpts

MAXI MOVE-1

MAXI MOVE™ Operating and Product Care Instructions

 Open the catalog to page 1
MAXI MOVE-2

GETINGE GROUP is a leading global provider of equipment and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences, Equipment, services, and technologies are supplied under the brands ARJO for patient hygiene, patient handling and wound care, GETINGE for infection control and prevention within healthcare and life science and MAQUET for surgical workplaces, cardiopulmonary and critical care. ARJO strongly advise and warn that only ARJO designed parts, which are designed for the purpose, should be used on equipment and other appliances supplied by...

 Open the catalog to page 2
MAXI MOVE-4

Thank you for purchasing ARJO equipment Your Maxi Move is part of a series of quality products designed especially for hospitals, nursing homes and other health care uses. We are dedicated to serving your needs and providing the best products available along with training that will bring your staff maximum benefit from every ARJO product. Please contact us if you have any questions about the operation or maintenance of your ARJO equipment. All references to the patient in these instructions refer to the person being lifted, and references to the attendant refer to the person who operates the Maxi...

 Open the catalog to page 4
MAXI MOVE-5

Safety Instructions Before using your Maxi Move, familiarise yourself with the various parts and controls as illustrated in Fig. 1, and other illustrations, then please read this manual thoroughly in its entirety before using your Maxi Move. Information in the manual is crucial to the proper operation and maintenance of the equipment, and will help protect your product and ensure that the equipment performs to your satisfaction. Some of the information in this booklet is important for your safety and must be read and understood to help prevent possible injury. If there is anything in the manual...

 Open the catalog to page 5
MAXI MOVE-6

Product Description/Function

 Open the catalog to page 6
MAXI MOVE-7

Product Description/Function Mast Adjustable chassis legs Braked castors 13 Lifter manoeuvring handle Jib Mast top cover DPS spreader bar Loop flat/walking jacket spreader bar Patient positioning handle Lifter battery pack Battery release button Patient scale (if fitted) Control handset Dual control panel Emergency stop button Reset button System failure lower override --Battery discharge indicator Minute meter Folding stretcher frame (if supplied) Soft stretcher (if supplied) Strap stretcher (if supplied) Scoop stretcher (if supplied) Jib with powered patient positioning spreader bar (if supplied)...

 Open the catalog to page 7
MAXI MOVE-8

Product Description/Function Note: The standard range of Maxi Move slings will support 228kg (500lbs), the peadiatric range will support 125kg (275lbs). All slings are coded for size by having different coloured edge binding as follows: Peadiatric rated: Teal -Extra Extra Small - XXS Brown - Extra small - XS Red - Small - S Standard range: Yellow - Medium - M Green - Large - L Purple - Large Large - LL Blue - Extra Large - XL Terracotta - Extra Extra Large - XXL A label is fitted to the hanger frame for quick colour to size reference (see “Labels” section). A range of special purpose slings are...

 Open the catalog to page 8
MAXI MOVE-9

Product Description/Function ARJO standard sling profiles that can be used with the Maxi Move Soft stretcher Toilet sling with head support General purpose sling with head support Four point Padded sling Four point toiletting sling (With headrest) Four point amputee sling Four point unpadded sling Four point mesh sling Fig. 2

 Open the catalog to page 9
MAXI MOVE-10

“Raise” Button The Maxi Move is fitted with a power saving feature which places the machine in ‘Sleep Mode’ when not used for a short time, to re-activate the machine press the up or down button. • Note: There will be a 3 seconds delay before the machine restarts from ‘Sleep Mode’. Control Handset:- (see fig 3) Raising and lowering the jib and opening and closing the chassis legs, is achieved by pressing the appropriate button on the control handset. Note: icons with direction arrows are printed on each button for quick reference. “Lower” Button Chassis leg close Button Chassis leg open Button...

 Open the catalog to page 10
MAXI MOVE-11

System Failure Lower Override:- (See fig 5) This can be used in the event of main control failure. In the unlikely event that the control handset or dual switch panel fails to operate the lifter, with a patient still supported by the sling or stretcher, provision for lowering has been made, using the “System Failure Lower Override switch”, situated on the right hand side of the controls console, a green and white identification label is positioned near the switch, for quick and easy recognition. If pressure is released from the switch during use, lowering will stop. Shaft lockscrew Warning: The...

 Open the catalog to page 11
MAXI MOVE-12

Product Description/Function Automatic stop function:- (not an operator control but a function built into the lifter electronics).Great care should be taken not to lower the spreader bar, or stretcher onto the patient or any other obstruction, but if this should happen inadvertently the motor will stop and downward movement will be held by the obstruction. If this occurs release pressure from the ‘lower’ button immediately, operate the ‘raise’ button until clear, then remove the obstruction. Battery Indicators:There are two types of battery indicator; (See fig 5) A Single red lamp, which will...

 Open the catalog to page 12
MAXI MOVE-13

Using your Maxi Move Before approaching the patient Powered opening ‘V’ chassis Ensure the battery pack supplied is fully charged before use (for charging, see instructions in “Lifter Battery Charging” section). When the battery pack is fully charged remove it from the charger unit and insert it into the battery position of the Maxi Move situated at the rear of the mast (see Fig. 1) by firstly, locating the recess across the bottom of the battery with the protrusion at the bottom of the battery position, then pivot the battery into position until the retaining catch operates. Electrical connection...

 Open the catalog to page 13
MAXI MOVE-14

Using your Maxi Move Using Maxi Move ‘Lock and Load’ system Warning: Check to see that the yoke is locked in place by trying to lift the yoke without pushing in the retaining catch. (see figs. 10 & 11) If your Maxi Move has not been supplied with a ‘dedicated’ or permanently attached, spreader bar, then it will be supplied with the ‘Lock and Load’ System jib. You may need to fit or change the attachment, (i.e.: spreader bar or stretcher fame) proceed as follows:- Retaining catch Note: The yoke should always be rotated to the correct position (see Fig. 11A) before attempting to install an attachment....

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.