OSMO STATION OM-6060
4Pages

{{requestButtons}}

Catalog excerpts

OSMO STATION OM-6060 - 1

Automatic Osmometer OSMO STATION™ Added user-friendliness with established reliability and functionality. Statisfies every need from

Open the catalog to page 1
OSMO STATION OM-6060 - 2

Automatic Osmometer OSMO STATION™ A popular automatic osmometer that satisfies all your clinical - Cooling base Concept diagram Temperature of sample during measurement Ultra cooling measurement method ARKRAY'S unique Ultra Cooling method enables noise-free and accurate measurement. < Freezing point depression principle > 1. Sample drawn into measurement cell. 2. Cooling temperature detection block keeps sample in a liquid state even if temperature falls to freezing point (Ultra Cooling state). 3. Cooling USC block to below freezing point allows sample to freeze into ice crystals. 4....

Open the catalog to page 2
OSMO STATION OM-6060 - 3

Free calibration Two-way calibration possible. Use purified water (OmOsm) and 2 reference solutions (300 mOsm / lOOOmOsm) (for when the osmotic pressure of the sample cannot be Analytical curve graph using 3 point calibration method Within-run reproducibility Use two kinds of solution (LOW/HIGH) with a known osmotic pressure. (Calibration method for when the osmotic pressure of the sample is roughly known.) The smaller the concentration region between "LOW" and "HIGH", the more accurate the data solution solution Analytical curve graph with 2 point calibration method Between-run...

Open the catalog to page 3
OSMO STATION OM-6060 - 4

This equipment is EMC specification JIS 0806-1:2001 compliant. 5S?1'. We cannot guarantee margin of error for measurement with samples other than serum, plasma We adopted the Freezing point depression method as the measurement principle. For this reason, we use sodium chloride solution as a reference solution for calibration. Please note that it is possible that some discrepancies in measurement value could arise when using samples that differ from sodium chloride solution in properties such as viscosity. 38$ 2 '• Please contact us in regard to changes in measurement range. 55;3-Urine spitz...

Open the catalog to page 4