Combi-flex®
12Pages

{{requestButtons}}

Catalog excerpts

Combi-flex® - 1

Universal Breathing Systems For Anaesthesia and Intensive Care ntroducing Armst anaesthesia and intensive care anaesthesia induction po/t-operotive bogging intensive care ventilation

Open the catalog to page 1
Combi-flex® - 2

Universal Breathing Systems po/l-opercilire baaain

Open the catalog to page 2
Combi-flex® - 3

Introducing the first multi-functional breathing circuit system, based on the original Universal F concept. Armstrong Medical now offers a selection of design configurations to cover all elements of respiratory support from anaesthesia preoxygenation through to intensive care ventilation, using a single system design. This brochure presents a range of standard configurations which can be further modified to suit individual customer requirements. with the world's first truly Universal Breathing System Expiratory limb, 26mm0. Warm and moist alveolar gases p insulation of the inspiratory limb....

Open the catalog to page 3
Combi-flex® - 4

Uses & Benefits Clinical Uses Depending on user requirements, the system can be configured for the following applications: Anaesthesia preoxygenation *• Anaesthesia induction using standard or vital capacity breath Anaesthesia maintenance using high- or low-fiow technique Post-operative recovery using standard therapy or Mapleson bagging technique Transportation to intensive care unit or high dependency unit Intensive care ventilation Clinical Benefits □ Single system for multi-procedure applications Eliminates the need for individual circuit types to cover all More efficient tidal volume...

Open the catalog to page 4
Combi-flex® - 5

Combi-rieK Complete Therapy System 4 This system is single patient use and intended to remain with the patient from the anaesthesia preoxygenation phase through to the end of intensive care ventilation'. The system comes preassembled for preoxygenation and can be easily configured for anaesthesia induction, maintenance, recovery, transportation and intensive care ventilation. Refer to inside back cover for Configuration Guidelines. Ultimately, refer to product Directions for Use for configuration of individual specifications. — Combi-Flex Limb — Expiratory Limb Water Trap Limb with b/v...

Open the catalog to page 5
Combi-flex® - 6

Design Options with elbows and gas sampling lines Basic Combi-fleK System Combi-fleH System for Paediatrics 1 ULTRACIear head strap 2 ULTRACIear face mask 3 Double swivel elbow

Open the catalog to page 6
Combi-flex® - 7

Combi-rieH System with Face Mask Combi-rieH System with Filter/HME

Open the catalog to page 7
Combi-flex® - 8

Combi-rioH Accessories Preoxygenation Adapter The preoxygenation/transportation adapter (22mmM) is used to connect the inspiratory port (22mmF) on the Combi-Flex Universal Breathing System to a standard oxygen flow meter to facilitate oxygenating the patient prior to, or in conjunction with, anaesthesia induction or for transportation. A bacterial viral breathing filter (see code 7010 on page 7) can be push-fitted between the adapter and the inspiratory port to facilitate limited reuse of the preoxygenation/transportation adapter (note that the filter should be replaced between uses of the...

Open the catalog to page 8
Combi-flex® - 9

Breathing Filters Mini Filter Mini Filter/HME Mini Filter with elbow Ported with elbow with elbow Ported with elbow with elbow Ported with elbow Ported with elbow Water Trap Limb Water trap limb The water trap limb is used for collection of water condensate, common during low flow anaesthesia and intensive care ventilation using passive or active humidification. The 22mmM on the water trap is push-fitted to the expiratory limb of the Combi-Flex Universal Breathing System with the tubing limb (22mmF) push-fitted to the expiratory port on the ventilator/anaesthesia absorber unit. The water...

Open the catalog to page 9
Combi-flex® - 10

Combi-ricK Accessories Bagging Limb with ULTRA APL Valve Mapleson bagging limb The bagging limb consists of the ULTRA APL valve, scavenging adapter and 2.0L Neoprene breathing bag. The limb is connected via the valve manifold (22mmM(15mmF)) to the expiratory limb (22mmF) of the Combi-Flex Universal Breathing System. Use of the limb facilitates pulmonary hyperinflation as part of preoxygenation, anaesthesia induction, post- operative oxygenation and transportation. A bacterial viral breathing filter (see codes 7010 and 7050 on page 7) can be push-fitted between the valve manifold and...

Open the catalog to page 10
Combi-flex® - 11

CeabiTICK Complete Therapy System 1. Preoxygenation/Transportation (requires preoxygenation/transportation adapter and anaesthetic face mask) If not already connected, push the 22mmM on the preoxygenation/transportation adapter into the 22mmF inspiratory port of the Combi-Flex; connect the other end to an oxygen flow meter (or common gas outlet on the anaesthetic machine); set the flow meter to 15L/min; prime the system with oxygen and secure mask to patient's face. Continue oxygenation as required. 2. Inhalational Anaesthesia Induction 2.1 Standard induction (may require anaesthetic face...

Open the catalog to page 11
Combi-flex® - 12

All Armstrong Medical products are manufactured to quality systems under BS EN ISO9000, IS013485, Armstrong Medical manufacture a complete range of respiratory products for anaesthesia and critical care applications. For supply of these products, or any product within the Armstrong Medical range, please contact your local Armstrong Medical Limited Wattstown Business Park Newbridge Road Northern Ireland

Open the catalog to page 12