E-Catalog
25Pages

{{requestButtons}}

Catalog excerpts

E-Catalog - 1

EVERYTHING ABOUT ORTHOPEDICS

Open the catalog to page 1
E-Catalog - 2

> RODU CTOS DE ALTA CALIDAD Quality has always been c entral to what we do. Since our founding, our top priority has been to offer consumers all around the world products that meet the very highest quality and performance standards. To achieve this, it takes three crucial things: • Complying with ISO and CE procedures, rules and regulations • A culture shared by all employees at every level • A manufacturing and packaging process that targets excellence. La calidad siempre ha sido central en lo que hac -emos. Desde nuestra fundacion, nuestra principal prioridad ha sido ofrecer a los...

Open the catalog to page 2
E-Catalog - 3

SHOULDER ARTHROSCOPY SOLUTIONS

Open the catalog to page 3
E-Catalog - 4

ordering information 16165015 artofix ti suture anchorwith needle6.5mm 16165016 artofix suture anchorwithout needle 6.5mm 16150015 artofix ti suture anchorwith needle 5.0mm 16150016 artofix ti suture anchorwithout needle 5.0mm 16135015 artofix ti suture anchorwith needle 3.5mm 16135016 artofix ti suture anchorwithout needle 3.5mm 16120016 artofix ti suture anchorwith needle2.0mm ARTOFIX TITANIUM SUTURE ANCHORS Titanium ARTOFIX suture anchors (available in 2.0mm,3.5 mm, 5.0 mm, and 6.5 mm diameters) feature a small minor diameter and a cancellous screw thread design. The anchor's very sharp...

Open the catalog to page 4
E-Catalog - 5

ordering information: PEEK SUTUREANCHORS ARTOFIX PEEK Suture Anchors provide surgeons with pullout strength, high-strength Fiber Suture, and multiple hole preparation options for any bone quality. Transitional thread design enables secure fixation with distal “cutting” and proximal “locking” threads, which means easy insertion and strongerpullout strength even in poorquality bone.Loaded with fiber sutures inside the body ofthe anchor means stronger knots .General hole preparation instrument offers solutions suitable for all qualities of bone.With a modulus similarto cortical bone,...

Open the catalog to page 5
E-Catalog - 6

ARTOFIX PEEK KNOTLESS ANCHORS Designed forarthroscopic instability orrotator cuff repair, the knotless suture anchor uniquely allows surgeons to adjust tension on the tissue intraoperatively, ensuring precise tissue reduction and fixation. Knotless anchors are available in 2.9 mm, 3.5 mm, 4.5mm and 5.5 mm sizes. The 2.9 mm and 3.5 mm Knotless anchors are optimized forlabral repair. Use the 4.5 mm and 5.5 mm Knotless anchorforrotatorcuffrepairusing the SutureBridge technique and the 3.5 mm Knotless anchor during rotatorcuff or instability procedures. The anchor bodies - available in...

Open the catalog to page 6
E-Catalog - 7

The braid structure developed for the purposes of the orthopedic surgery increases the performance and transportation characteristics of the suture. Thus, a flexible and easy-to- use orthopedic surgical suture that provides higher tensile strength than Polyester and polyblend sutures has been obtained. Fiber suture provides resistance to tighter knot and knot tear during bonding. The low knot profile of the seam allows precise knot placement and a smooth bond.The Ultrafire® suture is made from incredibly strong and durable ultra- high molecular weight polyethylene (UHMWPE) material. La...

Open the catalog to page 7
E-Catalog - 8

Most commonly utilized for soft tissue to ERQH Ć[DWLRQ LQ WKH VKRXOGHU 6HXWLOL]DFRQPD\RUIUHFXHQFLDSDUDODĆMDFLµQ de tejido blando a hueso en el hombro. Designed with a custom braid polyester sleeve and double loaded with #2 UHMPWE - ULTRAFIRE FIBER suture 'LVH³DGRFRQXQDPDQJDWUHQ]DGDGHSROL«VWHU personalizada y doblemente cargada con sutura # 2 UHMWPE - ULTRAFIRE FIBER &RORU FRGLQJ E\ GLDPHWHU ćRZ FRQWURO with sealings and transparent canulla for monitoring of the instrumentation. ORDERING INFORMATION ORDERING INFORMATION REF CODE: 9901002 SOFT ANCHOR 1.MM REF CODE: 9901004 SOFT ANCHOR 1.8MM...

Open the catalog to page 8
E-Catalog - 9

Fully threaded knotless SwiveLock anchors are designed for use with SutureTape, FiberSutures, Fiber Tapes, and soft-tissue grafts in repairand reconstruction techniques. Tension is visualized, adjusted, and locked into position with the SwiveLock anchorbody. Available in PEEK material, SwiveLock anchors are cannulated and vented to minimize material. 2.9mm SwiveLock anchoris available for instability repair and provides very high pullout and insertion strength while saving time. Los anclajes SwiveLock sin nudos completamente roscados estan disehados para usarse con SutureTape, Fiber...

Open the catalog to page 9
E-Catalog - 10

DOUBLE BUTTON SYSTEM FOR MINIMALLY INVASIVE AC JOINTREPAIR Artofix double button system introduces a novel technique forthe reconstruction ofcomplete acromioclavicularjoint separation by using an buttons with CL that has been modified foruse in the shoulder. The device is placed through holes in the coracoid and clavicle reproducing the course ofthe conoid portion ofthe coracoclavicularligament. The buttons with CL material has been shown to have both strength and stiffness in excess ofthe native anatomy, ensuring a stable reduction. The procedure is simple, has low morbidity, and can be...

Open the catalog to page 10
E-Catalog - 11

SUTURE LASSO The SutureLasso includes the 45 degree left - right curved, and the 30 degree up curved -straight and all are single use instruments packaged sterile. Each type has various curved tip configurations forarthroscopic Bankart, SLAP & rotator cuffrepairs. The SutureLasso has a2.3 mm outer diametertip and comes preloaded with nitinol braided wire loop ofsuture used to shuttle suture through soft tissue, these instruments can also be loaded with a monofilament suture forshuttling or with #2 Fiberto pass a stitch when using the knotless or SwiveLock anchors eliminating the shuttle...

Open the catalog to page 11
E-Catalog - 13

KNEE ARTHROSCOPY FOOT

Open the catalog to page 13
E-Catalog - 14

Orthosyn Double Button designed for Syndesmosis. It’s an important innovation that provides great convenience for surgery in sydesmosis operations which have a very important place in orthopedic surgical indications DQG WKDW VDWLVĆHVD GHVLUHG Ć[DWLRQDW WKH maximum level. Double button generally used in acramioclavicular ligament ruptures. Additionally, it’s used for syndemosis according to surgical indications in important joints such as ankle, knee and wrist. Double Button is a precontoured, titanium buttons that allows the use of multiple Fiber Sutures for V\QGHVPRWLF reduction, providing...

Open the catalog to page 14