ETA_SERIES
68Pages

{{requestButtons}}

Catalog excerpts

ETA_SERIES - 3

SERIES ASEM® also offers an interesting spectrum of colours in order to personalise the furniture such as EN 16121 SEVERA certified units and cabinets so that you can find your way around the laboratory more easily, draw attention to the company colours or simply appeal to your customer's tastes. Our aim is to design a more innovative, safer work environment that guarantees a high level of performance during day-to-day work. THE IMPORTANCE OF DETAIL The use of high quality materials is the basis of the philosophy behind the design of our furniture: it is designed to be strong, functional...

Open the catalog to page 3
ETA_SERIES - 5

How to design your laboratory 6 ETA_P wall bench 10 ETA_C central bench 11 Infill panels and fittings 22 Power supply and discharge fittings 23 Wash unit base 38 Wash unit accessories 39 Accessories (service outlet panel) 40 Reinforced bench tables 54 Anti-vibration bench tables 55 Technical chairs and stools 65

Open the catalog to page 5
ETA_SERIES - 6

6 HOW TO DESIGN YOUR LABORATORY To furnish your laboratory all you have to do is: 1 Take measurements of the room; 2 Indicate the position of the windows, doors and power sockets and discharges on the layout; 3 Indicate if there are any skirting boards, columns and coving present and their dimensions; 4 Select the worktop and type of base according to your needs; 5 Indicate the underbench units you require; 6 Personalise with accessories: taps, power sockets, panels. THE MODULAR CONCEPT OF OUR FURNITURE MAKES IT EASY TO ADAPT TO THE NEEDS OF ANY SPACE

Open the catalog to page 6
ETA_SERIES - 8

MAIN COMPONENTS • METAL FRAME WITH 60x30 mm C-FRAME STEEL TUBE LEGS • ERVICE COVER PANELS S • WORKTOP • R EAGENT SHELVING WITH THE ETA VERSION SERVICES ARE EITHER LOCATED ON A PREDRILLED BAR AT WORKTOP LEVEL OR ON A VERTICAL

Open the catalog to page 8
ETA_SERIES - 9

Our benches come in single side-by-side 600, 900, 1200, 1500 and 1800 mm base modules or in configurations with a single central leg which makes alignment easier. The bases are coated with epoxy acid-resistant resin in RAL 9010 Pure White. The wall benches have standard depths of 660 or 810 mm and the central benches depths of 1260 and 1560 mm.

Open the catalog to page 9
ETA_SERIES - 10

1 Glass fronted storage unit 2 Reagent shelving 3 EE turret 4 Water tap 5 Tap for gas - nitrogen - vacuum, etc. 6 Worktop 7 Side infill panels 8 Service cover panel 9 ETA base 10 Underbench unit 11 Colu mn s WALL BENCH

Open the catalog to page 10
ETA_SERIES - 11

7 Side infill panels 8 Service cover panel 9 ETA base 10 Underbench unit 11 Acrylic glass protective panels 12 Columns CENTRAL BENCH

Open the catalog to page 11
ETA_SERIES - 13

USER FRIENDLY The ASEM® service outlet panel (available as an option) is ideal for water, electrical and technical gas distribution. Ease of use and accessibility is the basis of achieving results by optimising space and time. MODULARITY AND SAFETY. THE VERTICAL PANEL FOR WALL-MOUNTED SERVICES. NOT ONLY PRACTICAL BUT ALSO SAFE.

Open the catalog to page 13
ETA_SERIES - 14

METAL MODULARITY C-frame leg support structure in pickled steel tube sprayed with epoxy resin powder in RAL 9010 Pure White (other colours available on request) and then placed in a heat tunnel at 180 °C. Height-adjustable steel feet coated in acid-resistant plastic. Worktop can be personalised to suit your requirements. The water and electrical services can be installed directly on the worktop on request. Available in widths of 60, 90, 120, 150, 180 and with a standard depth of 750 or reduced depth of 600, it also comes in heights of 770 or 900.

Open the catalog to page 14
ETA_SERIES - 15

IDEAL FOR LABORATORY AND OFFICE TABLES OR DESKS, ITS WIDE RANGE OF DIMENSIONS MAKE IT PERFECT FOR ANY ROOM.

Open the catalog to page 15
ETA_SERIES - 16

C FRAME CONFIGURATION OF BASE LEGS This gives the operator maximum freedom of movement since the frame legs are not at the front. The base of the frames with standard depth is set back to allow it to be placed against the wall if there is a skirting board and put into place after fitting power sockets and discharges on the wall. The side infill panel can be easily removed and can be shaped on request.

Open the catalog to page 16
ETA_SERIES - 17

It is made with 2 mm thick steel tubes with 60x30 and 60x60 sections. The protective coating on the metal structures involves pickling and hot phosphating and the application of electrostatically applied epoxy resin powder based paint (100±10 micron thick) in RAL 9010 Pure White (other colours available on request) and then dried in a heat tunnel at 180 °C. Height-adjustable steel feet coated in acid-resistant plastic. The bases of the elements with standard 60, 90, 120, 150 and 180 cm modularity have 2 legs with a 60x30 mm section. The wall benches with a single standard modular base can...

Open the catalog to page 17
ETA_SERIES - 18

SINGLE BASE The metal bases are made of 60x30 and 30x30 mm section steel tubes and are constructed as independent units which are modular and can be mechanically connected; the tight machining tolerances guarantee that the individual elements can be interchanged or replaced. EXCEPTIONAL STURDINESS WHICH CAN GUARANTEE A UNIFORMLY DISTRIBUTED LOAD OF OVER 200 KG/MZ SERVICES AT WORKTOP LEVEL Service outlet panel with 28 mm diameter holes and removable plastic caps. The protective coating on the metal structures involves pickling and hot phosphating and the application of electrostatically...

Open the catalog to page 18
ETA_SERIES - 19

SINGLE BASE AND MODULAR COMPOUND BASE IN YOUR LABORATORY

Open the catalog to page 19
ETA_SERIES - 20

COMPOUND BASE Bases consisting of frames with standard dimensions but with a single intermediate leg with a 60x60 mm section.

Open the catalog to page 20
ETA_SERIES - 21

PERFECT ALIGNMENT OF STRUCTURE, WORKTOPS AND REAGENT SHELVING. COMPOUND BASE As for all the central benches, shipping can only be done with the elements dismantled.

Open the catalog to page 21
ETA_SERIES - 22

INFILL PANELS AND FITTINGSSIDE INFILL PANELSPlastic laminate or metal panel placed on ends of bench. WSL9000 panel ETA_P white SIDE 810 x 900 mm (D x H) WSL9005M metal panel ETA_P white SIDE WSL9001M metal panel ETA_P white SIDE

Open the catalog to page 22
ETA_SERIES - 23

23 SUPPLY AND DISCHARGE FITTINGS PIPE FITTINGS This page contains recommendations on how to fit the connections in your laboratory. The supply pipes can be made of “Mannesmann” galvanised drawn steel and/or stainless steel depending on the liquid. The discharge pipes can be in Geberit or Nirlene polyethylene. IP 55-rated waterproof electrical box with G3 cables with 2.5 mm2 cross section for power sockets and single-phase control board. Our technicians are qualified to carry out the system, electrical, hydraulic, discharge and suction connections and issue system compliance certification in...

Open the catalog to page 23

All ASEM SRL catalogs and technical brochures

Archived catalogs

  1. RIC_SERIES

    50 Pages

  2. ETA_SERIES

    68 Pages

  3. Chemical hoods

    116 Pages