oxitamp-fibrillare-1

OXITAMP KNITTED® OXITAMP FIBRILLAR® OXITAMP FIBRILLAIR® OXITAMP FIBRILAR® OXITAMP FIBRILLAR THIN® OXITAMP FIBRILLAIR THIN® OXITAMP FIBRILAR THIN® OXITAMP FIBRILLAR 1 LAYER® OXITAMP FIBRILLAIR 1 LAYER® OXITAMP FIBRILAR 1 LAYER® OXITAMP POWDER® OXITAMP POUDRE® OXITAMP POLVO® ABSORBABLE HEMOSTATS HÉMOSTATIQUE RÉSORBABLE HEMOSTÁTICO ABSORBIBLE CE 0373

 Open the catalog to page 1
oxitamp-fibrillare-2

Absorbable hemostat of oxidized regenerated cellulose with Ph acid _ _ Indications: Main characteristics of Oxitamp®: • Rapid hemostatic effect (2-4 minutes) Oxitamp® is used adjunctively in surgical procedures to assist in the control • Completely absorbable of capillary, venous, and small artery haemorrhages when ligation or other • No harmful tissue reaction or reaction of hypersensitivity conventional methods of control are impracticable or ineffective. • Maximum resistance and manageability • Bactericidal effect • Absorption times (5-8 days) Hémostatique résorbable en cellulose oxydée régénérée...

 Open the catalog to page 2
oxitamp-fibrillare-3

OXITAMP KNITTED® Absorbable hemostat of oxidized regenerated cellulose with Ph acid The “Knitted” version is three times more thick and is characterized by a unique manifacturing process that offer maximum resistance to tearing. The product can be cut easily and applied according to the various surgical requirements. _ _ Main characteristics of Oxitamp Knitted®: Indications: • Rapid hemostatic effect (2-4 minutes) Oxitamp Knitted® can be used to control major bleeding such as paren• Completely absorbable chymatous organs. • No harmful tissue reaction or reaction of hypersensitivity • Easy to...

 Open the catalog to page 3
oxitamp-fibrillare-4

OXITAMP FIBRILLAR® | OXITAMP FIBRILLAIR® | OXITAMP FIBRILAR® Absorbable hemostat of oxidized regenerated cellulose with Ph acid _ Main characteristics of Oxitamp Fibrillar®: • Rapid hemostatic effect (2-4 minutes ) • Made in fibrillar form • Completely absorbable • No harmful tissue reaction or reaction of hypersensitivity • Maximum resistance and manageability • Average absorption time 5-8 days • Bactericidal effect Hémostatique résorbable en cellulose oxydée régénérée au PH acide _ Caractéristiques principales d’Oxitamp Fibrillair®: • 7 couches • Effet hémostatique rapide (2-4 minutes) • Réalisé...

 Open the catalog to page 4
oxitamp-fibrillare-5

OXITAMP POWDER® | OXITAMP POUDRE® | OXITAMP POLVO® Absorbable hemostat of oxidized regenerated cellulose with neutral Ph, in powder shape, sterile, ready to use. _ _ Main characteristics of Oxitamp Powder®: Indications: Oxitamp Powder® doesn’t need to be assembled, must be used dry and • Rapid hemostatic effect (2-4 minutes) directly sprayed where necessary the haemostasis. His exclusive • Bactericidal effect sterilized dispenser allows an easier and faster application even in • Completely absorbable through hydrolysis (4-6 days) also in difficult surgical procedures when the area is hard to...

 Open the catalog to page 5
oxitamp-fibrillare-6

OXITAMP GEL® Absorbable hemostat of oxidized regenerated cellulose with neutral Ph, in gel, ready to use. _ _ Indications: Main characteristics of Oxitamp Gel®: • Rapid hemostatic effect (2-4minutes) Oxitamp Gel® can be used in different gynaecological and cholecyst. • Bactericidal effect Indicated for open and laparoscopic surgery. • Completely absorbable through hydrolysis (4-6 days) also in blood absence • Due to its neutral pH, does not inactivate thrombin • No harmful tissue reaction or reaction of hypersensitivity Hémostatique résorbable en cellulose oxydée régénérée au PH neutre, sous...

 Open the catalog to page 6
oxitamp-fibrillare-7

Tidespon® is an absorbable hemostat sponge, sterile, for local use, _ made from 100% porcine gelatine. Eponge de gélatine hémostatique résorbable, stérile, pour usage local, constituée à 100 % d’origine porcine. _ bleeding. when implanted into tissue, Tidespon® is absorbed within 3-5 weeks. Tidespon® does not provoke any harmful tissue reaction or any reaction of hypersensitivity. The advantage of Tidespon® is the ability to use it simultaneously with antibiotics, chemotherapeutic medications implanté dans le tissu, Tidespon® est résorbé en 3-5 semaines. Tidespon® ne provoque aucune réaction...

 Open the catalog to page 7
oxitamp-fibrillare-8

ITALIA Headquarter Zona Industriale 67062 Magliano dei Marsi (AQ), Italy Tel.+39 0863 517956/515000 Fax +39 0863 570084/515209 Legal Office Via G. Gregoraci, n.12 00173 Roma Tel. +39 06 72677348 Fax +39 06 72675380 FRANCE 86-114 Avenue Louis Roche Batiment D Hall-3 92230 Gennevilliers Tel. +33 147985294 Fax +33 147985892 ESPAÑA Poligono Landaben Calle C, nave 1y2 - 31012 Pamplona (Navarra) Tel. +34 948122274 Fax. +34 948120842 GERMANY Prager Strasse 34 04317 Leipzig UK Unit 12a Barncliffe Mills Shelley HD8 8LU Huddersfield Tel. +44 1484602222 USA 55 NE 5th Avenue, Suite 501 33432 - 4093 Boca Raton...

 Open the catalog to page 8