O ERGONOMICS • three completely independent treatment channels • operation mode: program / manual • preset treatment program and sequence base • statistics - the number of performed treatments • encyclopedia with treatment methodology description • treatment programs chosen by name or medical field • concise list of favorite programs • buzzer volume setting • possibility of edition the names of user-defined programs and sequences • self-test - systematic control of the unit • 7" color touchscreen • real time clock • battery ELECTROTHERAPY • operation in CC (stabilized output current) and CV (stabilized output voltage) modes • electrodes test • generation of unidirectional (unipolar) currents in interrupted mode • complete galvanic isolation between channels in each mode CURRENTS - interferential (dynamic, isoplanar, one-channel (AMF)) - TENS (symmetric, asymmetric, alternating, burst) - TENS to spastic paralysis therapy - Kotz' / Russian stimulation - tonolysis - diadynamic (MF, DF, CP, CP-ISO, LP) - pulse - rectangular, triangular - Trabert pulse, Leduc' pulse - unipolar sine surge - galvanic - microcurrents ASTAR • physio
Open the catalog to page 1ELECTRODIAGNOSTICS • electrodiagnostics with graphic presentation of I/t curve • automatic calculation of rheobase, chronaxie as well as accommodation coefficient ULTRASOUND THERAPY • • • • • • • • operation frequency 1 MHz/3,5 MHz effective radiation area 1 cm2 and 4 cm2 continuous emission – thermal effect pulse emission – micro massage effect ultrasound heads provided with the contact control connected to treatment timer precise control over the ultrasound wave emission during performed treatment head sensitivity calibration automatic control of emitted power LASER THERAPY • • • • •...
Open the catalog to page 2TECHNICAL SPECIFICATION • • • • • • • • • • • • controller – max constant current in patient’s circuit (CC mode) – galvanic 40 mA – diadynamic, pulse 60 mA – interferential, Kotz, unipolar sine surge 100 mA – TENS 140 mA – tonololysis 100 mA – microcurrents 1000 µA max voltage in patient’s circuit (CV mode) 140 V max ultrasound wave intensity in continuous / pulse mode 2 / 3 W/cm2 pulse frequency 16 Hz, 48 Hz, 100 Hz duty factor for pulse mode 5 – 75 %, step 5 % laser device class 3B max. magnetic field induction ...
Open the catalog to page 3• magnetic field applicator - CPE type with covers • magnet • patient's stop switch • PRO bag for the unit and accessories • Versa trolley ASTAR • physiotechnology
Open the catalog to page 4All ASTAR catalogs and technical brochures
-
ASTAR CATALOGUE 2024
72 Pages
-
Radiofrequency unit TECARIS
2 Pages
-
PhysioGo.Lite LASER
3 Pages
-
PhysioMG EN
2 Pages
-
Versa, Versa X
2 Pages
-
Impactis M+
2 Pages
-
POLARIS HP_EN
2 Pages
-
Distribution flyer
2 Pages
-
Versa XUVC EN
2 Pages
-
PhysioGo Lite SONO EN
2 Pages
-
PhysioGo Lite ELECTRO EN
2 Pages
-
STAR products catalogue 2022
68 Pages
-
Lumina with table stand
2 Pages
-
Sonaris S - ultrasound unit
2 Pages
-
Sonaris M - ultrasound unit
2 Pages
-
PhysioGo 300A - combo
3 Pages
-
Etius - electrotherapy unit
2 Pages
-
Avaco - vacuum therapy unit
2 Pages
-
Etius U - combo
4 Pages
-
PhysioGo 701I - product card
4 Pages
-
PhysioGo 701C - product card
3 Pages
-
PhysioGo 601C - product card
2 Pages
-
PhysioGo 500 - product card
3 Pages
-
PhysioGo 300 - product card
3 Pages
-
PhysioGo 200 - product card
2 Pages
-
PhysioGo 100 - product card
2 Pages
-
PhysioGo
2 Pages
-
Polaris HP M
5 Pages
-
Polaris HP S
5 Pages
Archived catalogs
-
ASTAR products catalogue 2021
60 Pages
-
Products Catalogue 2020/2021
33 Pages