Catalog excerpts
High power and biostimulation laser therapy Polaris HP M Single-module laser therapy unit intended for carrying out treatment procedures with the use of high power and biostimulation laser radiation. The effectiveness of treatment procedures with the use of Polaris HP unit is based on the application of a high-power source of a single wavelength which results in deep penetration into tissue and local thermal effect, which are not observed in the case of low-level laser therapy. Built-in laser source may operate in either continuous or pulse mode with maximum power equal to 8 W. Pulse mode is used to reduce the thermal effect. At the time of exceeding the average power of 4 W, the unit displays an additional warning to prevent excessive overheating. In order to enable efficient and precise deep intratissue laser therapy, a special DILA adapter has been developed (Deep Intratissue Laser Adapter) It is specifically designed optical system allowing for laser beam formation in such a way to compensate the power loss in the surface tissues. The application of adapter reduces the thermal effect in the skin and subcutaneous tissue. Another advantage is more precise location of the treatment site. DILT method and DILA adapter are unique solutions of ASTAR company and they are covered by registered trademark property protection. The controller has the possibility of operation in manual mode, where it is possible to set up power, frequency and duty factor. Modern design of the HP probe provides easy replacement of adapters. Depending on the treatment procedure there is a possibility to apply DILA adapter or two types of application adapters which give 1 cm2 or 5 cm2 treatment radiated area. The unit is compatible with all types of low level laser applicators manufactured by ASTAR company. It is possible to connect point probes, scanning and cluster laser applicators. By this option, the unit may be used for performing biostimulation laser therapy treatment procedures. Starting laser therapy procedures, we may take advantage of the encyclopedia, ie. built-in list of preset programs with an extensive description of the treatment methodology. Therapist may also create own programs as well as treatment sequences and save them in the unit’s internal memory.
Open the catalog to page 1High power and biostimulation laser therapy Polaris HP M SPECIFICATION LASER THERAPY • built-in high power laser source – 808 nm/8 W • three application adapters: 1 cm2, 5 cm2, DILA • cooperation with: scanning applicators, cluster laser applicator and point probes • power adjustment • radiation modes: continuous, pulse and super pulse • duty cycle or pulse time setting • automatic treatment time calculation on the basis of treatment area • dedicated modes for operation with optical fiber applicators SCANNING APPLICATOR (optional) • emitter power measured on output • two available version...
Open the catalog to page 2High power and biostimulation laser therapy Polaros HP M MANUAL MODE complete control over parameters for advanced users TREATMENT PROGRAMS • simplification of the unit operation • treatment programs chosen by name • 51 programs for high power laser therapy treatment • 57 programs for point probes • 26 programs for scanning applicator • 54 programs for cluster laser applicator • 250 user-defined programs • 8 programs with Nogier frequency • 30 programs with Voll frequency • favorite program list for each applicator • illustrated therapeutic encyclopedia TREATMENT SEQUENCES • simplification...
Open the catalog to page 3Polaris HP M Technical specification ERGONOMICS • large, 7” inch color touch screen • therapeutic encyclopedia with treatment description • operation mode: program/manual • power stabilization and adjustment • treatment automatic repetition • counter of laser applicator operation • statistics of performed treatments • automatic laser power measurement test • list of favorite programs • buzzer volume setting • emergency laser stop key • easy replacement of adapters • pilot beam indicating application area • edition of user-defined programs • self test – systematic control of the unit...
Open the catalog to page 4Polaris HP M Technical specification OPTIONAL ACCESSORIES • Deep Intratissue Laser Adapter • point probe – R 660 nm/40 mW with holder • point probe – R 660 nm/80 mW with holder • point probe – IR 808 nm/200 mW with holder • point probe – IR 808 nm/400 mW with holder • scanning applicator – R+IR 50 mW + 400 mW with a stand • scanning applicator – R+IR 100 mW + 450 mW with a stand • cluster laser applicator CL 1800 5R x 40 mW + 4IR x 400 mW with holder • optical fiber applicator, straight, Ø 6 mm • optical fiber applicator, straight, Ø 8 mm • optical fiber applicator, angled 45°, Ø 6 mm •...
Open the catalog to page 5All ASTAR catalogs and technical brochures
-
ASTAR CATALOGUE 2024
72 Pages
-
Radiofrequency unit TECARIS
2 Pages
-
PhysioGo.Lite LASER
3 Pages
-
PhysioMG EN
2 Pages
-
Versa, Versa X
2 Pages
-
Impactis M+
2 Pages
-
POLARIS HP_EN
2 Pages
-
Distribution flyer
2 Pages
-
Versa XUVC EN
2 Pages
-
PhysioGo Lite SONO EN
2 Pages
-
PhysioGo Lite ELECTRO EN
2 Pages
-
STAR products catalogue 2022
68 Pages
-
Lumina with table stand
2 Pages
-
Sonaris S - ultrasound unit
2 Pages
-
Sonaris M - ultrasound unit
2 Pages
-
PhysioGo 300A - combo
3 Pages
-
Etius - electrotherapy unit
2 Pages
-
Avaco - vacuum therapy unit
2 Pages
-
Etius U - combo
4 Pages
-
PhysioGo 701I - product card
4 Pages
-
PhysioGo 701C - product card
3 Pages
-
PhysioGo 601C - product card
2 Pages
-
PhysioGo 500 - product card
3 Pages
-
PhysioGo 300 - product card
3 Pages
-
PhysioGo 200 - product card
2 Pages
-
PhysioGo 100 - product card
2 Pages
-
PhysioGo
2 Pages
-
Polaris HP S
5 Pages
Archived catalogs
-
ASTAR products catalogue 2021
60 Pages
-
Products Catalogue 2020/2021
33 Pages