

Catalog excerpts

NEWSFLASH NEW: TRACOE comfort plus With the new product group TRACOE comfort plus product innovation and scientific findings merged into a new perfect long-term tracheostomy tube The patients benefit from the comfortable fit of the TRACOE comfort plus tracheostomy tube, while the optimised air stream through the upper airway supports a good phonation. Like the entire TRACOE comfort line, the comfort plus is hand-made out of thermo-sensible, DEHP-free PVC material. The TRACOE comfort plus is available in three different configurations in the sizes 07, 08, 09, 10 and 11. The tube sets ensure a high quality, continuous wearing experience of up to six month. Double fenestrated inner cannula with 22 mm adapter, e.g. for our membrane speaking valve REF 650-S Double fenestrated inner cannulas with integrated flap speaking valve Closed inner cannula with 15 mm connector, e.g. for an HME / artificial nose REF 640-CT Double fenestrated inner cannula with 22 mm adapter, e.g. for an HME / artificial nose REF 640-S REF 164 Double fenestrated inner cannulas with integrated flap speaking valve Closed inner cannula with 15 mm connector, e.g. for an HME / artificial nose REF 642
Open the catalog to page 1
NEWSFLASH Opitmised length of tube • The Body-Mass-Index (BMI) increases dramatically worldwide g The tubing of the TRACOE comfort plus is extended • The position of the multiple fenestration holes: further distal on the outer bend of the cannula g Better position in the tracheal lumen Double Fenestration • Two additional phonation holes at the inner bend g Improved expiratory air stream through the natural airway Optimized 100° bending angle • Good positioning of the tube in the tracheostoma Speaking valve Type B with closure-safety • The flap valve is protected from accidental deformation...
Open the catalog to page 2
NEWSFLASH Dimensions of the TRACOE comfort plus line in sizes 07 to 11 TRACOE comfort, standard TRACOE comfort plus TRACOE comfort, extra-long Bending angle approx. 90° OD-OC bc: ID-IC: OD-OC bf: Length OB: Bending angle approx. 90° Bending angle approx. 100° Outside diameter at bottom of outer cannula Inside diameter at bottom of inner cannula Outside diameter of outer cannula behind the flange Length along outer bend (greatest length) * Among other input data from the study „An investigation into the length of standard tracheostomy tubes in critical care patients* of A. Mallick et al....
Open the catalog to page 3All ATOS Medical catalogs and technical brochures
-
470-P
4 Pages
-
REF 721
1 Pages
-
REF 720
1 Pages
-
tracoe-catalogue-2014
94 Pages
-
Newsflash - switch
2 Pages