Capillary closure occurs at 32 mmHg. Anything above 32 mmHg appears as RED. Look how the red disappears as better surfaces are applied to this subject. AFT is the ONLY surface keeping the subject well below capillary closure throughout the entire body. The colors tell the story! Look what happens... ...when a 190 lb. subject lies down on different surfaces! Want to give your patients comfortable support without a lot of pressure? Pressure mapping technology accurately demonstrates interface pressure levels of patients’ body forces exerted against different surfaces from... 190 lb subject on carpet oor | Highest pressure 100 mmHg 190 lb. subject on hospital mattress | Highest pressure 75 mmHg Manufacturing, LLC HydroAire - “Lightening the Pressure” Aurora MFG can provide the best relief mattresses for patients at risk for or who have pressure ulcers. Group 1 Gel Overlay 190 lb subject on Group 1 gel overlay | Highest pressure 52 mmHg AFT helps patients best The Air-Fluidized Therapy (AFT) bed is the Gold Standard in providing the best surface for patients with Stage 3 or 4 ulcers! Provide your facilities with the best therapy available... Air Fluidized Therapy with the HydroAire AFT Bed.. Group 2 Low Air Loss Mattress Group 3 HydroAire AFT 190 lb. subject on Group 2 low air loss mattress Highest pressure 47 mmHg 190 lb subject on Group 3 HydroAire AFT | Highest pressure 26 mmHg