LabPad INR

LabPad INR

LabPad INR

Product catalog summary
Overview: The document describes a handheld device designed for blood analysis using Tsmart® technology. It outlines the device's features, testing procedures, and quality control measures.
Device Specifications:
  • Simple operation in three steps: insert Tsmart®, drop blood, discard Tsmart®.
  • Ergonomic design with a silicone band for comfortable handling.
  • Touchless release to prevent contamination.
  • Unique 3D-shaped microcuvette requiring only a 3µL blood sample.
  • DataMatrix for built-in quality control (QC) and no need for a code chip.
  • Single-packed consumables for reagent stability and room temperature storage.
Testing Procedures:
  • Conducted at Grenoble University Hospital with 200 subjects using capillary blood and two Tsmart® INR lots.
  • Comparison of INR results with the ISO 17593:2007 standard using the STA-R Evolution® analyzer.
  • Real-life testing in French biology lab Oriade-Noviale with 84 subjects on VKA drugs using five LabPad® INR devices.
Quality Control:
  • Three built-in QC measures: reading DataMatrix, checking Tsmart® micro channel filling, and an embedded algorithm for coagulation dynamics.
  • External QC with two INR levels for liquid control.
Device Features:
  • 3D-shaped microcuvette for easy handling.
  • Sample size: 3µL of capillary whole blood.
  • Measuring time: less than 1 minute.
  • Test shelf-life: 18 months.
  • Connectivity: Bluetooth Low Energy and USB B port.
  • Built-in battery and memory for 1,000 results.
  • Automatic ejection of consumables.
Manufacturer: AVALUN SAS, Grenoble, France ©2019
See more

Catalog excerpts

LabPad INR-1

Handheld device Unique microcuvette 3µL small blood sample insert Tsmart® drop blood discard Tsmart® No need for code chip Comfortable handling, silicone band and shape to fit human hands Touchless release preventing from contamination Single packed to ensure reagent stability Room temperature storage

 Open the catalog to page 1
LabPad INR-2

The study was performed in Grenoble University Hospital using capillary blood from 200 subjects on two Tsmart® INR lots and two LabPad® analysers. Laboratory testing was performed using corresponding venous blood with the core-lab STA-R Evolution® analyzer using CI Plus reagent from Diagnostica Stago. INR results were compared according to the ISO 17593:2007 standard. The study was conducted in real-life laboratory routine conditions in the French biology lab Oriade-Noviale. A total of 84 subjects receiving VKA drugs were enrolled. Five different LabPad® INR devices and two different lots of...

 Open the catalog to page 2

All Avalun catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.