Patient Monitoring Solutions
Open the catalog to page 1For Out-Patient Department, Spot-check, Transport, Ward and other Basic Monitoring. Configuration Optional SpO2 + NIBP, Li-ion battery Features 8" color TFT LCD Screen (touch screen optional) Portable, lightweight and sturdy design Flexible parameters configuration for different clinical environments Rechargeable Li-ion Battery (up to 12 hours uninterruptable work) Big font and font color display setting Spot-check and continuous monitoring mode Selectable for Adult, Pediatric and Neonatal patients Wired/Wireless CMS, support HL7 protocol to HIS Barcode scanner support Thermal recorder support Graphical...
Open the catalog to page 2PAVO Vital Sign MonitorTechnical Specifications NIBP Measurement method: Automatic oscillometric method Operating mode: Manual, automatic, continuous Measurement unit: imimHg/kPa selectable Typical measurement time: 20~40 s Measurement type: Systolic, Diastolic, Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-270 Pediatric 40-230 Neonatal 40-135 Range of Diastolic pressure: Adult 10-210 Pediatric 10-150 Neonatal 10-100 Range of Mean pressure: Adult 20-230 Pediatric 20-165 Neonatal 20-110 Measurement accuracy Maximum average error: ±5 mmHg Maximum standard deviation: 8 mmHg Resolution:...
Open the catalog to page 3Features • 12.1" color TFT LCD screen • 8 waveform display, up to 12-lead ECG analysis • Powerful calculation (Hemodynamic, Drug Dose, Oxygenation, Ventilation) • Pacemaker detection • ST & arrhythmia analysis • OxyCRGs screen • Wired/Wireless CMS, support HL7 protocol to HIS • SpO2 pulse-tone modulation (Pitch Tone) • MEWS (Modified Early Warning Score) • Graphical & tabular trend review (120 hours) • Rechargeable Lithium-Ion Battery (2600 mAh) 12.1”color TFT LCD screen, wide and flat screen design,ecnomic and reliable Configuration: ECG+SpO2+NIBP+2TEMP+PR+RESP, Li-ion battery Optional: Touch-Screen,...
Open the catalog to page 4CETUS X12 Patient Monitor Technical Specifications NIBP Measurement method: Automatic oscillome-tric method Operating mode: Manual, automatic, continuous Measurement unit: imimHg/kPa selectable Typical measurement time: 20~40 s Measurement type: Systolic, Diastolic, Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-270 Pediatric 40-200 Neonatal 40-135 Range of Diastolic pressure: Adult 10-210 Pediatric 10-150 Neonatal 10-95 Range of Mean pressure: Adult 20-230 Overpressure protection: Software and hardware, double safety protection Cuff pressure range: 0-280 mmHg SpO2 Measurement...
Open the catalog to page 5CETUS x15 Critical Care Patient Monitor Multiple parameter options satisfy the need for ICU, CCU, NICU. Technical Specifications Configuration: 5-lead ECG, SpO2, NIBP, TEMP, Resp, PR; Li-ion battery Optional: Touch-Screen, 12-lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-Gas, BIS, NMT, VGA, Thermal Recorder, Wired/Wireless CMS Notch: 50/60 Hz notch filter can be set to on or off Differential input impedance >5MΩ Electrode polarization voltage range: ±400mV Baseline recovery time <3s after defibrillation (in monitor and surgery mode) Calibration signal: 1 mV (peak - peak), accuracy ±3%...
Open the catalog to page 6CETUS X15 Critical Care Patient Monitor Technical Specifications Range of Mean pressure: Adult 20-230 Pediatric 20-165 Neonatal 20-105 Measurement accuracy Maximum average error: ±5 mmHg Maximum standard deviation: 8 mmHg Resolution: 1 mmHg Interval: 1,2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minutes Overpressure protection: Software and hardware, double safety protection Cuff pressure range: 0-280 mmHg IBP (Optional) Channel: 2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP: -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution: 1mmHg Accuracy:...
Open the catalog to page 7Aspect BISx module (Optional) Parameter Measurement: BC: 0~30 (Only limited to the combined use of an external sensor with a BIS module) EMG: 30~55 dB (bar chart) with intensity between 30 dB and 80 dB (tendency chart) BIS: 0~100 SQI: 0%~100% SR: 0%~100% SEF: 0.5 Hz~30 Hz TP: 40~100 Db EEG Measurement: Input impedance >5 MQ Noise (RTI) <2 pV (0.25~50 Hz) Input signal range: ±1 Mv EEG bandwidth between: 0.25 Hz~110 Hz NMT Tof-Watch® SX (Optional) Microprocessor-controlled Stimulation Mode: TOF, TOFS, PTC, 1 Hz Twitch, 0.1 Hz Twitch, DBS DBS3.3 and 3.2 (Double Burst), Tetanic Stimulation (Burst), 5s...
Open the catalog to page 8CETUS xl Advanced Patient Monitor Multiple parameter options satisfy the needs of ICU, CCU, NICU Configuration: 5-lead ECG, SpO2, NIBP, Resp, PR; Li-ion battery Optional: 12-lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-gas, BIS, NMT; VGA, Thermal Recorder, Wired/Wireless CMS Masimo SET® SpO2 Provides anti-motion and anti-low perfusion SpO2 measurement. Masimo Phasein IRMA™/ISA Sidestream/Mainstream EtCO2 Allows selection of the modality best suited to the application, monitoring with infrared absorption technique. Features • 15.6”/17/19” switchable TFT LCD Touch Screen • Aluminium material...
Open the catalog to page 9Technical Specifications CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance >5 MQ Electrode polarization voltage range: ±400 mV Baseline recovery time <3s after defibrillation (in monitor and surgery mode) Calibration signal: 1 mV (peak - peak), accuracy ±3% RESP Measurement method: Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, x0.5, xl, x2 Respiratory impedance range: 0.5-5 Q Baseline impedance: 500-4000 Q Gain: 10 grades Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s TEMP Accuracy: ±0.1 °C or ±0.2 °F (without probe) Measurement...
Open the catalog to page 10CETUS xl Advanced Patient Monitor Technical Specifications Standard Mainstream CO2 (Optional) Measurement range: 0-19.7%, 150 mmHg, or 0-20kPa Resolution: 0.1 mmHg Measurement accuracy 0 - 40 mmHg: ± 2 mmHg 41 - 70 mmHg: ± 5% of reading 71 - 100 mmHg: ± 8% of reading 101 - 150 mmHg: ± 10% of reading Respiration rate: 3-150 bpm Respiration rate accuracy: 1% ±1 bpm Warm-up time: 97% within 8s, full accuracy within 20s Standard Sidestream CO2 (Optional) Measurement rage: 0-20% (0-150 mmHg) Accuracy: < 5.0% CO 2: ± 2 mmHg > 5.0% CO 2: < 6% of reading Respiration rate: 2~150 BPM Respiration rate...