1. Catalogs
  2. aXcent medical
  3. Patient Monitoring Solutions
video corpo

Patient Monitoring Solutions
1 /24Pages

Patient Monitoring Solutions

Patient Monitoring Solutions
1 /24Pages

Catalog excerpts

Patient Monitoring Solutions-1

Patient Monitoring Solutions

 Open the catalog to page 1
Patient Monitoring Solutions-2

Features • 8" color TFT LCD Screen (touch screen optional) • Portable, lightweight and sturdy design • Flexible parameters configuration for different clinical environments • Rechargeable Li-ion Battery (optional up to 12 hours uninterruptable work) • Big font and font color display setting • Spot-check and continuous monitoring mode • Selectable for Adult, Pediatric and Neonatal patients • Wired/Wireless CMS, support HL7 protocol to HIS • Barcode scanner support • Thermal recorder support • Graphical & tabular trend review • 48 hours holographic wave review for each patient

 Open the catalog to page 2
Patient Monitoring Solutions-3

For Out-Patient Department, Spot-check, Transport, Ward and other Basic Monitoring. Configuration Optional Technical Specifications 8" color TFT LCD Screen, resolution: 800 x 600 Wave sweep speed: 6.25 mm/s, 12.5 mm/s, Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR >100dB Notch: 50/60 Hz notch filter can be set to on or off Differential input impedance >5 MQ Electrode polarization voltage range: ±400 mV Baseline recovery time <3 s after defibrillation (in monitor and surgery mode) Calibration signal: 1 mV (peak - peak), accuracy...

 Open the catalog to page 3
Patient Monitoring Solutions-4

PAVO Vital Sign Monitor Technical Specifications NIBP Measurement method: Automatic oscillometric method Operating mode: Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40 s Measurement type: Systolic, Diastolic, Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-270 Pediatric 40-230 Neonatal 40-135 Range of Diastolic pressure: Adult 10-210 Pediatric 10-150 Neonatal 10-100 Range of Mean pressure: Adult 20-230 Pediatric 20-165 Neonatal 20-110 Measurement accuracy Maximum average error: ±5 mmHg Maximum standard deviation: 8 mmHg Resolution:...

 Open the catalog to page 4
Patient Monitoring Solutions-5

Infrared Ear Thermometer (optional) Displayed range: 34~42.2 °C (93.2~108 F°) Operation ambient temperature range: 10~40 °C (50~104 °F) Accuracy for displayed temperature range: Phasein IRMA™ Sidestream CO2 (optional) Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50 ml/min (+/-10/min) Accuracy: ± (0.2% +2% of the reading) Measurement Range: 0 -15% Rise time: 200 ms, typical at 50 ml/min flow rate Total response time: within 3 seconds (with 2m Momoline sampling line) AWRR Range: 0-150 bpm AWRR Accuracy: ±1 breath Phasein IRMA™ Mainstream CO2 (optional) Measurement Range: 0-15%...

 Open the catalog to page 5
Patient Monitoring Solutions-7

CETUS X12 Patient Monitor • 10 waveform display, up to 12-lead ECG analysis • Useful calculation (Hemodynamic, Drug Dose, Oxygenation, Ventilation) • Pacemaker detection • OxyCRGs screen • Wired/Wireless CMS, support HL7 protocol to HIS • SpO2 pulse-tone modulation (Pitch Tone) • MEWS (Modified Early Warning Score) • Graphical & tabular trend review (120 hours) • Rechargeable Lithium-Ion Battery (2600 mAh)

 Open the catalog to page 7
Patient Monitoring Solutions-8

12.1”color TFT LCD screen, wide and flat screen design,ecnomic and reliable Configuration: ECG+SpO2+NIBP+2TEMP+PR+RESP, Li-ion battery Optional: Touch-Screen, 12-lead ECG, Masimo SpO2, 2/4/6 IBP, C.O., EtCO2, Multi-Gas, BIS, NMT, VGA, Thermal Recorder, Wired/Wireless CMS Technical Specifications Display 12.1” TFT (touch screen optional) Resolution: 800 x 600 Number of traces: 10 waveforms ECG Lead type: 3-lead, 5-lead, 12-lead ECG waveform: 2 channels, 7 channels, 12 channels Display sensitivity: 2.5 mm/mV (×0.25), 5 mm/mV (×0.5), 10 mm/mV (×1.0), 20 mm/mV (×2.0) Wave sweep speed: 6.25 mm/s,...

 Open the catalog to page 8
Patient Monitoring Solutions-9

CETUS x12 Patient Monitor Technical Specifications NIBP Measurement method: Automatic oscillometric method Operating mode: Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40 s Measurement type: Systolic, Diastolic, Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-270 Pediatric 40-200 Neonatal 40-135 Range of Diastolic pressure: Adult 10-210 Pediatric 10-150 Neonatal 10-95 Range of Mean pressure: Adult 20-230 Pediatric 20-165 Neonatal 20-105 Measurement accuracy Maximum average error: ±5 mmHg Maximum standard deviation: 8 mmHg...

 Open the catalog to page 9
Patient Monitoring Solutions-11

CETUS x15 Critical Care Patient MonitorFeatures • 15.6" High resolution TFT LCD Touch screen • 10 waveform display, up to 12-lead ECG analysis • Useful calculation (Hemodynamic, Drug Dose, Oxygenation, Ventilation) • Pacemaker detection • Aspect BISx module, NMT module optional • Wired/Wireless CMS, support HL7 protocol to HIS • SpO2 pulse-tone modulation (Pitch Tone) • VGA support external display • Graphical & tabular trend review (120 hours) • 48 hours full disclosure wave review for each patient

 Open the catalog to page 11
Patient Monitoring Solutions-12

CETUS x15 Critical Care Patient Monitor Multiple parameter options satisfy the need for ICU, CCU, NICU. Configuration: ECG, SpO2, NIBP, TEMP, Resp, PR; Li-ion battery Optional: Touch-Screen, 12-lead ECG, Masimo SpO2, 2/4/6 IBP, C.O., EtCO2, Multi-Gas, BIS, NMT, VGA, Thermal Recorder, Wired/Wireless CMS Masimo SET® SpO2 Provides anti-motion and anti-low perfusion SpO2 measurement. Bispectrial Index™ by Aspect Monitor the level of consciousness of the patient under general anesthesia or sedation. provides BIS, SQI, EMG, SR, SEF, TP, PC value and EEG wave. Masimo Phasein IRMATM/ISA Sidestream/Mainstream...

 Open the catalog to page 12
Patient Monitoring Solutions-13

Technical Specifications Notch: 50/60 Hz notch filter can be set to on or off Differential input impedance >5MΩ Electrode polarization voltage range: ±400mV Baseline recovery time <3s after defibrillation (in monitor and surgery mode) Calibration signal: 1 mV (peak - peak), accuracy ±3% RESP Measurement method: Thoracic electrical bioimpedance Rate: 0 – 150 bpm Measuring lead: Lead I, II Wave gain: ×0.25, ×0.5, ×1, ×2 Respiratory impedance range: 0.5-5 Ω Baseline impedance: 500-4000 Ω Gain: 10 grades Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s TEMP Accuracy: ±0.1 or ±0.2 °F (without probe) Measurement...

 Open the catalog to page 13

All AXcent medical catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.