IMPRESSION COMPONENTS PULL-OFf TRANSFER Each pack contains 3 pcs INN-00306 Pull-off impression transfer (closed tray technique) Place the plastic transfer by pressure-fitted into the implant hexagon and make some little lateral movements to check the correct position of the transfer (Fig. 1). Prepare a standard impression tray and inject elastomeric implant transfer and into the impression tray (Fig. 2). Once the material is solid, remove the impression and pressure-fitted the analog into the impression model (Fig. 3). NOTE: It is important to use a tear resistant material. PLASTIC CaP Each pack contains 2 pcs INN-00507 FACILITY transfer (closed tray technique) COMPLETE SET - plastic cup - screw - metal transfer short INN-00506 long INN-00506L Place the transfer impression inside the implant and make sure that the internal hex is correctly engaged screwdriver using light finger force. After that place correctly the plastic cap on the transfer (Fig. 1). Prepare a standard impression tray and inject elastomeric implant transfer and into the impression tray (Fig. 2). Once the material is solid, remove the impression and take out the impression copings to attach the Analog INN-00585 analog and correctly reposition into the impression model (Fig. 3). PICK-UP TRANSFER (OPEN TRAY TECHNIQUE) Place the impression transfer inside the implant and make sure that the internal hex is correctly engaged before tightening the screw using light Fig. 1 finger force (Fig. 1). Prepare a customized impression tray and inject elastomeric COMPLETE SET - post screw - metal trasfer INN-00600 implant transfer and into the impression tray. So take the impression (Fig. 2). Once the material is solid, loosen the guide screw and remove the tray. Then reposition and fix the analog in the impression using the screw. Long pick-up screw INN-00608L Analog INN-00585
Open the catalog to page 1PICK-UP TRANSFER (OPEN TRAY TECHNIQUE) Place the impression transfer inside the implant and make sure that the internal hex is correctly engaged before tightening the screw using light finger force (Fig. 1). Prepare a customized impression tray and inject elastomeric impression material around the implant transfer and into the impression tray. So take the impression (Fig. 2). Once the material is solid, loosen the guide screw and remove the tray. Then reposition and fix the analog in the impression using the screw. FACILITY TRANSFER 0 3 (CLOSE Tray TEcHNIQUE) Place the transfer impression...
Open the catalog to page 2All B&B DENTAL catalogs and technical brochures
-
T-BARRIER
4 Pages
-
OralSed
2 Pages
-
A SMILE FOR EVERYONE
9 Pages
-
Implatn bdbdental
2 Pages
-
PTERYGOID IMPLANTS
4 Pages
-
MILLING CENTER
20 Pages
-
GUIDED SURGERY TECHNIQUE
36 Pages
-
Novocor Plus
6 Pages
-
DURAVIT WIDE
3 Pages
-
Duravit 3p
5 Pages
-
Prosthetic Procedures
40 Pages
-
Surgical Procedures
36 Pages
-
Products Catalog
88 Pages