NCB e3 Brochure - 115V
1 / 8Pages

Catalog excerpts

NCB e3 Brochure - 115V - 1

Standards Laboratories Listed

Open the catalog to page 1
NCB e3 Brochure - 115V - 2

NCB™ e3 - Class II Type B1 Biological Safety Cabinets Developed to exceed the National Cancer Institute's Expectations… and Yours. The NCB™ e3 Class II Type B1 biological safety cabinet exceeds the requirements of the National Cancer Institute (NCI) specification for a General Purpose Clean Air Biological Safety Cabinet. The cabinet includes unique Baker design features that have been proven to enhance containment while inhibiting cross contamination and exposure to chemicals, vapors and gases. • All exhaust air is removed directly from the work area and pulled through a dedicated exhaust...

Open the catalog to page 2
NCB e3 Brochure - 115V - 3

Baker Builds it Better Craftsmanship Ensures Quality Baker cabinets represent many years of experience in fabrication and craftsmanship. Our design improves comfort, simplifies cleaning, and maintains proper containment. • Work surface and walls are one-piece, corrosion-resistant stainless steel with smooth radius corners for easy cleaning. A white powder finish protects the cold-rolled steel cabinet exterior. • The entire cabinet is airtight. Each component is welded, gasketed, or assembled with hermetically sealed joints. At the factory prior to shipping, each cabinet is bubble-tested...

Open the catalog to page 3
NCB e3 Brochure - 115V - 4

Superior Protection and Maximum Efficiency StediFLOW™ VFD Motor Controller Automatically Achieves Optimum Performance Baker’s StediFLOW™ VFD motor controller uses less energy, reduces heat output, and operates more quietly. VFD is state-of-the-art technology in HVAC systems for performance and energy savings. • Maintains precise airflow - automatically compensates for normal power line variations, air disruptions, and filter loading. • Provides constant air volume - reduces risk of performance degradation, which can compromise personnel and product protection. • xtends filter life -...

Open the catalog to page 4
NCB e3 Brochure - 115V - 5

Comfortable and Easy to Use The NCB™ e3, like all Baker cabinets, includes design features to improve safety, productivity, user-comfort, and performance throughout a range of tasks performed on a daily basis. Our cabinets are designed with the user in mind so that routine tasks can be done comfortably, efficiently, and with less fatigue. Highly Productive Work Environment Design considerations such as wide radius corners, aerodynamically shaped surfaces, and glare-reducing satin finish interiors combine to improve comfort, simplify cleaning, and maintain proper containment. • arge...

Open the catalog to page 5
NCB e3 Brochure - 115V - 6

Technical Specifications MODEL NUMBER Usable Workspace (w x d) Exterior Dimensions (w x d x h [min to max]) Cabinet Weight Shipping Weight Working Access Opening Height (8” standard) Operating Amperage Power Consumption Heat Generation Electrical Service Requirement Noise, exhaust & cabinet, NSF International EXHAUST AND STATIC PRESSURE REQUIREMENTS Working Access Opening Height Exhaust Flow Rate (Total CFM) Exhaust Static Pressure Adjusted Value (Per NSF 49) 8" Exhaust Duct Diameter 10” Exhaust Duct Diameter 12” Exhaust Duct Diameter Options and Accessories Most options, accessories, and...

Open the catalog to page 6
NCB e3 Brochure - 115V - 7

Purchase Specifications Technical Specifications NCB™ e3 Class II Type B1 Biological Safety Cabinet, Vertical Flow, 115 V, 60 Hz Model PERFORMANCE 1. Manufacturer shall provide a certified copy of the personnel, product, and crosscontamination (biological) tests, equivalent to or more demanding than as specified in NSF International Standard 49, performed on the unit selected from the corresponding statistical sample. Tests may be witnessed by a representative of the purchaser. The unit shall have standard HEPA filters for a protection effectiveness of 99.99% on 0.3 micron size particles by...

Open the catalog to page 7
NCB e3 Brochure - 115V - 8

Caution Class II, Type B1 cabinets may be used for work with volatile chemicals and radionuclides required as adjuncts to microbiological studies. Theses cabinets may also be used for work treated with volatile chemicals and radionuclides required as an adjunct to microbiological studies if work is done in the direct exhausted portion of the cabinet, or if the chemicals or radionuclides will not interfere with the work when recirculated in the downflow air (as stated in National Sanitation Foundation International Standard #49). Note: The adequacy of this containment cabinet for the user’s...

Open the catalog to page 8