GlidePath
8Pages

{{requestButtons}}

Catalog excerpts

GlidePath - 1

Exceptional Performance and Ease of Placement Long-Term Dialysis Catheter has joined BD

Open the catalog to page 1
GlidePath - 2

SIMULATED FLOW PERFORMANCE Lower PressuresLower is Better GlidePath® catheters demonstrated on average 15% higher flow rates in forward and reverse flow compared to Palindrome™ Precision catheters1 GlidePath® catheters demonstrated on average 16% lower pressures in the arterial lumen compared to Palindrome™ Precision catheters1 Blood Simulant1At Max Arterial Pressure (-250 mmHg)11 600 ro 400 200 Catheter Precision Catheter Catheter Precision Catheter Forward Reverse to 3 O Catheter Precision Catheter Catheter Precision Catheter 23 cm catheters111 .2 'Z a> < 300 (ml/min) Flow 11 400 (ml/min)...

Open the catalog to page 2
GlidePath - 3

Computational Fluid Dynamic Model Flow Performance And Lumen Design Lumen Design is the Difference Lumen Designed to Minimize Deflection Under Pressure to Improve Flow Performance -13 % Pinched Lumen Corners May Impact Flow Performance Computational Model of Arterial and Venous flow streams at 300ml/min -Forward Flow 11 Excellent Recirculation Rates 1% or Less on Average in Both Forward and Reverse1 Improved Inner Lumen Design Represents catheter lumen wall and septum deflection when flowing at 400ml/min and at max. allowable arterial pressure (when -250mm Hg is reached per KDOQI Standard)....

Open the catalog to page 3
GlidePath - 4

FLOW-PRESSURE PERFORMANCE Flow-Pressure Under Partial Occlusion Lower Pressure is Better GLIDEPATH® catheters demonstrated on average 16% lower arterial pressures compared to Palindrome™ Precision catheters‡ Average Pressure (mmHg) Blood Simulant* Average Pressure (mmHg) G P Palindrome Catheter Precision Catheter Palindrome™ G P Catheter Precision Catheter 300 (ml/min) Flow‡‡ Forward 23 cm catheters‡‡‡ 300 (ml/min) Flow‡‡ Reverse Arterial Side of the Catheter Tip Forced Against the Tube Wall During Flow Bench data on file. May not necessarily correlate to clinical performance. Groups found...

Open the catalog to page 4
GlidePath - 5

GlidePath Long-Term Dialysis Catheter One Pre-Loaded Stylet to Simplify Over-the-Wire Placement* Smooth Tapered Tip and Tapered Cufffor Easy Insertion AirGuard® Valved Introducer Reduces Risk of Air Embolism Integrated Valve AirGuard® Valved Introducer Fixed Suture Wings Provide Stability Tapered Cuff Thermosensitive Polyurethane Shaft SureCuff® Tissue In-Growth Cuff Catheter Size Introducer Size GlidePath® Catheter Palindrome™ Precision Catheter ‘Straight codes only Tip Designed to Resist Positional Occlusion Symmetric Tip Design

Open the catalog to page 5
GlidePath - 6

SURFACE ROUGHNESS Front Openings1 Surface is Better SEM Images**** Palindrome™ Precision Average 0.962(gm) Side Holes1 Smoother Surface is Better GlidePath® Median 0.506(gm) Representative Images * Optical Profilometry tested using Zygo Optical System on the edges of the distal tip features, N=20 per group, GlidePath® and Palindrome™ Precision. * 1 Groups found to be statistically different using an unstacked ANOVAwith p-value less than 0.05 at 95% confidence (0.000 for all comparative groups). Calculation of at least 2X smoother based upon the ratios of mean surface roughness values. * 11...

Open the catalog to page 6
GlidePath - 7

Kink Diameter* Smaller Kink Diameter is Better The GlidePath® catheter shaft demonstrated on average up to 7% smaller kink diameter values when compared to the Palindrome™ Precision catheters** Kink Diameter= Furthest Distance Achieved Before Kink Occurs Kink Diameter * Tested using catheter shafts from 23cmtiptocuff straight catheters (GlidePath n=20, Palindrome Precision n=20) * * Groups found to be statistically different using an Unstacked ANOVAwith p-value less than 0.05 at 95% confidence (0.000 for all comparative groups). Calculation based upon the ratios of average kink diameter...

Open the catalog to page 7
GlidePath - 8

Ordering Information GlidePath® Catheters - Straight GlidePath® Catheters - Alphacurve® Catheter Tip to Cuff Tip to Hub Standard Kit Length Length Product Codes GlidePath® Catheters - Straight 14.5 Fr Catheter 15 Fr AirGuard® Valved Introducer with Peel-Away Sheath/ Dilator 10 - 12 Fr Dualator® Dilator Insertion Stylet Tunneler 2 End Caps ID Card IFU Introducer with Peel-Away Sheath/ j • 18 Gauge Introducer Needle i • 2 Adhesive Dressings • ID Card • IFU GlidePath® Catheters - Alphacurve® Catheter Standard Kit Contents The Alphacurve® Catheter Standard Kit comes with the same contents as...

Open the catalog to page 8

All Bard Medical catalogs and technical brochures

  1. CTO-Family

    10 Pages

  2. MRI Safety

    2 Pages

  3. HemoStarXK

    2 Pages

  4. POWERFLOW®

    8 Pages

  5. BARDEX I.C.

    2 Pages

  6. SURESTEP

    4 Pages

  7. AGENTO

    4 Pages

  8. ISOSLEEVE

    4 Pages

  9. READYLINK

    6 Pages

  10. SOURCELINK

    6 Pages

  11. SourceCap

    4 Pages

  12. ALYTE

    4 Pages

  13. ARCTICGEL

    2 Pages

  14. IAP Brochure

    4 Pages

  15. INLAY OPTIMA

    4 Pages

  16. INLAY

    4 Pages

  17. EXPAND212

    4 Pages

  18. U-NITE

    2 Pages

  19. Filiforms

    4 Pages

  20. UROFORCE

    4 Pages

  21. X-FORCE

    8 Pages

  22. ENDOBEAM

    4 Pages