T 180/3 320

T 180/3 320

T 180/3 320

Product catalog summary
Specifications:
The document provides detailed specifications for three types of lifters: T 180/2, T 180/3 580, and T 180/3 320. Each lifter operates at a voltage of 24 V/DC with a maximum power input of 144 W and a power consumption of 6 A. The lifters have a protection rate of up to IP54 and an isolation class of III. The environment temperature range for operation is between +10°C and +40°C.
Performance Parameters:
The maximum push force for the T 180/2 is 1000 N, while for the T 180/3 models, it is 800 N. The pull force is 600 N for T 180/2 and 400 N for the T 180/3 models. The maximum static and dynamic lengthwise and lateral loads are 200 Nm and 100 Nm, respectively, for all models. The speed without load is 25 mm/s.
Design and Construction:
The T 180/2 is a 2-stage lifter, while the T 180/3 models are 3-stage. The standard retracted lengths are 640 mm for T 180/2, 580 mm for T 180/3 580, and 320 mm for T 180/3 320. The stroke lengths are 500 mm, 700 mm, and 370 mm, respectively. Fixing points for both inner and outer profiles are 4 x M6 screws.
Additional Features:
All models include integrated end switches and have a stroke tolerance of +/- 2 mm. The pulse travel length varies slightly between models. The lifters are equipped with a Molex Mini Fit Jr. plug type and have a cable length of 1200 mm. The cycle duty is 1/9 (10%).
Graphical Data:
The document includes graphs illustrating the relationship between current (I) and force (F), as well as speed (V) and force (F), providing insights into the performance characteristics under different loads.
See more

Catalog excerpts

T 180/3 320-1

Lifter type Article number Max. lengthwise load statical Max. lateral load statical Max. lateral load dynamical Speed (without load) Max. stroke (custom made)** Retracted length (Standard) Stroke (Standard) Length/Stroke calculation Lifter version Fixing points inner profile *** Fixing points outer profile*** Environment temperature Protection rate* Pulse travel length (2-Hall) Isolation class Stroke tolerance (+/- 2mm) and operating speed depending on load and voltage *Depends on installation position **Other retracted length/stroke/pull application on demand *** Screws self cutting/forming according to DIN 7500, thread depth min. L= 2,5 x D Controllers and add-on components see accessoires

 Open the catalog to page 1

All Baumeister & Schack catalogs and technical brochures

  1. LIFTERS T 175

    2  Pages

  2. LIFTERS T 180

    2  Pages

  3. TYP 120 S

    2  Pages

  4. TYP 200 S

    2  Pages

  5. TYP 200 KS

    2  Pages

  6. TYP 110 D

    2  Pages

  7. TYP 100

    2  Pages

  8. TYP Koax E

    2  Pages

  9. TYP 110 E

    2  Pages

  10. VISOLIFT

    2  Pages

  11. TR 126/3

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.