Overview: The VICTUS® Femtosecond Laser Platform by Bausch & Lomb is a versatile laser system designed for ophthalmic procedures such as LASIK and cataract surgeries. It features live-action optical coherence tomography (OCT) for enhanced visualization and precision.
Indications for Use: The platform is indicated for creating corneal flaps in LASIK surgery, performing anterior capsulotomy during cataract surgery, making corneal incisions, and laser-assisted lens fragmentation for nuclear cataracts. It is not suitable for posterior subcapsular (PSC) and cortical cataracts.
Contraindications: The system should not be used in patients with corneal diseases affecting laser transmission, pregnant or nursing individuals, those with existing corneal implants, or those who have had previous corneal surgery. Other contraindications include glaucoma, retinal disorders, and certain systemic conditions like diabetes and severe wound healing disorders.
Technical Specifications: The laser is a diode-pumped solid-state laser with a wavelength of 1040 ± 25nm and pulse frequencies of 80 or 160 kHz. It operates with a power supply of 230 VAC and has a heat load of 3000 watts. The system includes a main laser unit, patient bed, and a sterile patient interface kit. It is classified as a Class 3B laser under IEC 60825-1:2007 standards.
Advanced Features: The platform includes intelligent pressure sensors and a curved patient interface to enhance patient comfort and procedure accuracy. The advanced docking system minimizes eye tilt and distortion, ensuring precise alignment and reducing the risk of complications.
Installation Requirements: The laser room must meet specific dimensions and structural requirements, including corridor widths and floor load capacities, to accommodate the system safely. Environmental requirements include controlled temperature and humidity levels, and the room must be free of dust and chemical fumes.
Service and Support: Bausch & Lomb provides comprehensive support, including installation, training, and ongoing assistance, to ensure seamless integration into clinical practice. The platform is supported by a global service organization and offers 24/7 access to educational resources.
See more

Catalog excerpts

VICTUS® Femtosecond Laser Platform-1

VICTUS® Femtosecond Laser Platform

 Open the catalog to page 1
VICTUS® Femtosecond Laser Platform-2

FEMTOSECOND TECHNOLOGY THAT EMPOWERS VICTUS® is the industry-leading femtosecond laser that provides exceptional performance across cataract and corneal applications on a single platform. VICTUS takes versatility to an entirely new level, enabling you to perform capsulotomies, fragmentation, arcuate incisions, corneal incisions, and even LASIK flaps. In all of its features and capabilities, VICTUS is engineered to meet the standards of the clinician who truly embraces innovation. The VICTUS Platform is indicated for use in the creation of a corneal flap in patients undergoing LASIK surgery or other...

 Open the catalog to page 2
VICTUS® Femtosecond Laser Platform-3

UNPARALLELED VISUALIZATION An extension of your own skilled hands, VICTUS® begins every procedure with accuracy and control. Advanced docking technology is designed to reduce the possibility of eye tilt and distortion, allowing for better centration, more precise cutting and fragmentation, greater stability, and reduced vacuum requirements—while minimizing the possibility of posterior corneal folds or ripples. Visibility of the surgical field is optimized by live-action optical coherence tomography (OCT) to keep the surgeon in command, from planning throughout treatment. Time after time. As a...

 Open the catalog to page 3
VICTUS® Femtosecond Laser Platform-4

UNCOMPROMISING PERFORMANCE Ophthalmic surgery, by its nature, requires the utmost precision. That precision came only with painstaking effort. Until now. Exclusive VICTUS® live-action OCT, along with an easy-to-use graphic interface, provide advanced visual guidance at all times. These systems, together with the VICTUS Intelligent Pressure Sensors, enable the surgeon to control procedure-optimized downward pressure, with customized settings for corneal and cataract applications. But the key to the unmatched capabilities of VICTUS is the laser itself. The VICTUS laser’s fast pulse rates and small...

 Open the catalog to page 4
VICTUS® Femtosecond Laser Platform-5

INCOMPARABLE VERSATILITY Your practice has seen many changes through the , years, but nothing quite like this. With VICTUS® your capabilities aren’t merely extended—they’re multiplied. The two-piece, curved interface and Intelligent Pressure Sensors are fundamental to the versatility of VICTUS. Together, these components enable Dual-Modality Performance, which is the unique ability of VICTUS to dock with full contact for corneal applications, or to utilize a liquid layer for cataract applications. In addition, the surgeon is able to shift modalities during a procedure, seamlessly adapting to...

 Open the catalog to page 5
VICTUS® Femtosecond Laser Platform-6

TECHNICAL SPECIFICATIONS ADVANCED DOCKING SYSTEM SYSTEM APPLICATIONS INDUSTRY-LEADING SERVICE AND SUPPORT Capsulotomy Diode-pumped solid state laser Precise alignment designed to maintain the natural Phacofragmentation (DPSSL) LIVE-ACTION OCT Cataract Procedures Corneal incisions shape of the eye Wavelength 1040 ± 25nm Arcuate incisions All-inclusive practice or 160 kHz depending resources Clinical application support 80 The VICTUS® Femtosecond Laser Platform features Corneal Procedures LASIK flap Pulse Frequency on procedure Customized laser integration and ongoing support Complete, on-site training...

 Open the catalog to page 6
VICTUS® Femtosecond Laser Platform-7

VICTUS Technical Specifications ® VICTUS System Dimensions Installation Requirements All corridors and doorways leading to the laser room must be wider than 33 inches (no doorstops less than 79 inches behind doors) Corridors narrower than 47.5 inches must have no 90° corners If a ramp is necessary to overcome stairs, an angle of 20° should not be exceeded The floor leading to and in the room must support 1654 lb for the laser and 552 lb for the bed, plus the weight of personnel and patient (eg, 662 lb) The room must not have been painted within 3 weeks prior to installation If an elevator must...

 Open the catalog to page 7
VICTUS® Femtosecond Laser Platform-9

ADVANCED DOCKING SYSTEM Precise alignment designed to maintain the natural shape of the eye The VICTUS® Femtosecond Laser Platform features advanced docking technology that minimizes the possibility of eye tilt or distortion. The VICTUS docking system provides: Flexible 2-piece Curved Patient Interface offers: Separate suction clip designed to fit all eye topographies without distorting the cornea Precise initiation of suction, designed to minimize the possibility of suction loss Easy pupil alignment and tilt adjustment Docking monitored by the Intelligent Pressure Sensors Two-piece design and...

 Open the catalog to page 9
VICTUS® Femtosecond Laser Platform-10

VICTUS Advanced Docking System ® Optimized by Intelligent Pressure Sensors and the unique, two-piece Curved Patient Interface Dual-Modality Performance VICTUS provides the unique ability to dock two ways. For cataract applications, VICTUS offers non-contact docking with a thin liquid layer separating the cornea from the Curved Patient Interface. For corneal applications, VICTUS docks with full contact to optimize stability and precision. Dual-Modality Performance enables the surgeon to change modalities during a procedure, selecting “wet to dry, on the fly” as needed. Intelligent Pressure Sensors...

 Open the catalog to page 10
VICTUS® Femtosecond Laser Platform-11

NDUSTRY-LEADING SERVICE AND SUPPORT All-inclusive practice resources ► Customized laser integration and ongoing support provided by dedicated specialists ► Assistance through all phases of the implementation process, from evaluation to installation, training, communication, and ongoing support ► 24/7 access to the online PANORAMA® Program containing a broad spectrum of patient and staff educational tools Clinical application support ► Complete, on-site training for the surgeon ► Staff training and support programs to ensure seamless adaptation to your practice Femtosecond Laser Platforr

 Open the catalog to page 11
VICTUS® Femtosecond Laser Platform-12

VICTUS : Support that sets the standard ® Bausch + Lomb brings you VICTUS—the industry-leading femtosecond laser for cataract and corneal procedures on a single platform. Comprehensive technical support Hotline support Troubleshooting lobal service organization of highly trained, G certified application specialists and technical service engineers Installation and orientation Site inspection, evaluation, and release by specialized field engineers Transportation to the clinic/laser room, plus evaluation and support System installation, operational tests, quality Assurance of rapid response, personal...

 Open the catalog to page 12

All Bausch + Lomb catalogs and technical brochures

  1. VICTUS

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.