BD FACSLyricTM Flow Cytometry System
9Pages

{{requestButtons}}

Catalog excerpts

BD FACSLyricTM Flow Cytometry System - 1

BD FACSLyric Flow Cytometry System TM

Open the catalog to page 1
BD FACSLyricTM Flow Cytometry System - 2

The next generation of flow cytometry The BD FACSLyric flow cytometry solution combines simplicity, speed and automation to ease workflow and improve productivity. This next-generation flow cytometer enables standardization and collaboration through consistent results and unique assay portability capabilities. BD FACSLyric Discover the difference of the BD FACSLyricTM flow cytometry system. • Witness clinical performance results you have never seen before, through high sensitivity and improved resolution • Streamline your lab workflow through flexibility and automation, enabling efficiency...

Open the catalog to page 2
BD FACSLyricTM Flow Cytometry System - 3

Improvement in stain index of 8–190% across all parameters, ensures better separation and enables faster analysis and easier gating. (Figure 2) Figure 2. Improvement in stain index enhances peak resolution of the BD FACSLyric as compared to the BD FACSCanto™ II system One set of single-color stains of peripheral blood samples was acquired on a BD FACSCanto II and a BD FACSLyric cytometer. Stain index was calculated for all parameters on both instruments. The % increase in stain index (BD FACSLyric/BD FACSCanto II) is shown. Histograms from the BD FACSLyric and the BD FACSCanto II are also...

Open the catalog to page 3
BD FACSLyricTM Flow Cytometry System - 4

Improving efficiency and productivity through flexibility and automation Intelligent system design simplifies your laboratory workflow through built-in flexibility and automation thus enabling your technicians to be more productive. Spend zero minutes on startup and shutdown. • Pre-programmable startup means instruments are ready to run the minute users walk in • Automated shutdown and power off also contributes to maximizing instrument productivity Automation streamlines your daily workflow, improving efficiency and productivity. STARTUP Automated startup at scheduled days and times SETUP...

Open the catalog to page 4
BD FACSLyricTM Flow Cytometry System - 5

Elevating standardization and collaboration to a new level Universal Setup ensures reproducible and accurate results day to day with stable instrument performance of <0.4%. (Figure 4) The BD FACSLyric was designed with collaboration in mind. The unique assay portability feature enables the sharing and exchange of data, ideas and userdefined protocols within and between institutions. • User-defined assays are saved and electronically transferred • Assay portability simplifies and standardizes instrument via USB or email to another BD FACSLyric system setup within your lab and between labs,...

Open the catalog to page 5
BD FACSLyricTM Flow Cytometry System - 6

Highly reproducible results between instruments drive standardization. 15 BD FACSLyric Systems: Lyse/Wash settings and BD FC beads Blue laser Violet laser Figure 6. Corresponding overlays of 15 BD FACSLyric systems show between-instrument variability of less than 8% for the red and blue channels Table 1. Between-instrument reproducibility of target MFI values on the BD FACSLyric Lyse/wash assay settings were imported across 15 instruments to show effects of standardization on beads. The CVs of the fluorescence intensity across all channels varies by less than 15.3%. (Figure 5) Daily QC with...

Open the catalog to page 6
BD FACSLyricTM Flow Cytometry System - 7

Data management software Acquisition and analysis software that is robust and reliable, with many functions and options relevant to 21 CFR Part 11. • Password protection, audit trail, electronic signatures and IQ/OQ procedures assist in supporting 21 CFR Part 11 compliance and electronic record integrity. • The BD FACSuite Clinical and BD FACSuite applications have a common user interface and identical menu navigation. • Reports are customizable with tables, headers and footers. • Built-in flexibility for creating customized calculations and expressions. • With Microsoft® Windows® 10...

Open the catalog to page 7
BD FACSLyricTM Flow Cytometry System - 8

Flow cytometry solutions, built on a foundation of excellence, experience and expertise Clinical laboratories expect high-quality solutions when they come to BD, a collaborative partner with more than 40 years of experience in flow cytometry. BD is committed to providing excellence and expertise in the clinical environment with an innovative portfolio of solutions, products and tools. Training Course offerings led by BD instructors and application support specialists include training on instruments, software and applications. This training is delivered in a wide range of formats including...

Open the catalog to page 8
BD FACSLyricTM Flow Cytometry System - 9

BD FACSLyric™ Flow Cytometer with the BD FACSuite™ Clinical and BD FACSuite™ Applications, BD FACS™ Universal Loader, BD® CS&T Beads and BD® FC Beads Kits (7-Color, 5-Color and 2-Color) are in vitro diagnostic medical devices bearing a CE mark. The BD Multitest™ 6-Color TBNK with optional BD Trucount™ Tubes are in vitro diagnostic medical devices bearing a CE mark and are CE certified by BSI Group the Netherlands B.V. (Notified Body Number = 2797). In the EU, the BD FACSCanto™ II Flow Cytometer is no longer available for sale. The BD FACSLyric™ Flow Cytometer is a Class 1 Laser Product. Cy™...

Open the catalog to page 9