BeaconMedaes Lifeline Manifolds-2

Trouble Free Operation The LifeLine® Global Manifold is designed in accordance with NFPA, CSA and ISO standards. The improved design, validated through extensive testing, ensures the manifold maintains its reliability while reducing the potential for leaks, avoiding wasteful gas losses. The NEMA 4 enclosure and environmental testing provides the ability for outdoor installations. Our LifeLine® Global Manifolds are designed to be superior performers in any medical gas service. • • • • • • • TotalAlert Embedded Capabilities Ultra high flow (tested to ISO 10524-2) Fully automatic Dome loaded regulators...

 Open the catalog to page 2
BeaconMedaes Lifeline Manifolds-3

Vent valve pre-piped to vent port NEMA 4 Enclosure houses both the power supply and control board Line regulators and check valves are housed in brass forging to minimize connection points, therefore eliminating the potential for leaks Service valve Pressure Switch (Pressure Transducer for TAE models) Robust solenoid valve LED Electronics Overlay for easy visual status of gas flow NFPA HP x HP Version Shown Bank regulators and check valves are housed in brass forging to minimize connection points, therefore eliminating the opportunity for leaks

 Open the catalog to page 3
BeaconMedaes Lifeline Manifolds-4

Lifeline Cylinder Manifold Flow Capacities Delivery Pressure Minimum Flow rate This flow rate is the minimum flow rate which will be expected just prior to switchover. With full cylinders, the flow rate may be considerably higher. Always compare manifolds at switchover. Lifeline Liquid Manifold Flow Capacities Liquid x Liquid x Reserve Bulk liquid x Liquid x Reserve Liquid containers have limits in their rate of delivery and are typically more limited than the manifold. Given below are typical output capacities for single liquid containers. With two liquid containers on a header, this capacity...